Dual mobility design socket use in preventing total hip replacement dislocation following tumor resection

被引:0
|
作者
Philippeau, J. -M. [1 ,2 ]
Durand, J. -M. [3 ]
Carret, J. -P. [3 ]
Leclercq, S. [4 ]
Waast, D. [1 ]
Gouin, F. [1 ,2 ]
机构
[1] Hop Hotel Dieu, Dept Orthoped, F-44035 Nantes 01, France
[2] Univ Nantes, Sch Med, Bone Resorpt & Primit Bone Tumor Physiopathol Res, INSERM,EA 3822,U957, F-44000 Nantes, France
[3] Hop Edouard Herriot, F-69437 Lyon 03, France
[4] St Martin Private Hosp, F-14000 Caen, France
关键词
Dislocation; Total hip replacement; Dual mobility cup; Hip tumor; Tripolar arthroplasty; Quality of life; PROXIMAL FEMORAL RECONSTRUCTION; ALLOGRAFT-PROSTHESIS COMPOSITE; SURGICAL-TREATMENT; PATHOLOGICAL FRACTURES; FUNCTIONAL-EVALUATION; ARTHROPLASTY; COMPLICATIONS; MANAGEMENT; MEGAPROSTHESIS; EXTREMITY;
D O I
10.1016/j.otsr.2009.10.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Total hip replacement (THR) following hip tumor resection incurs a high risk of dislocation. We assessed the incidence of dislocation associated with use of a dual mobility cup, and the functional results achieved. Hypothesis: Use of a dual mobility cup would reduce the risk of THR instability following hip tumor resection. Material and methods: We analyzed dislocation rates in a retrospective series of 71 dual mobility cup THRs implanted following the resection of a tumor hip condition: 33 primary bone tumors and 38 bone metastases. The presenting pathology was diagnosed anatomically, and surgery classified in terms of adopted abductor system strategy. Functional results were assessed in terms of pain (analgesia on the World Health Organisation [WHO] scale), assisted walking and Musculoskeletal Tumor Society (MSTS) score. Results: An overall rate of 9.8% dislocation was observed, taking into account all etiologies and contexts together. More precisely, this rate resulted from a compound figure of 5.2% in bone metastasis and 15% in primitive bone tumor. Dislocation risk depended less on etiology than on the surgical management of the abductor system, being 3.5% in the case of abductor conservation, 9.5% in the case of abductor sectioning/reinsertion, and 18% in case of gluteus medius muscle or nerve resection. Functional improvement was consistently observed, especially in bone metastasis. At the maximal follow-up, 32 patients were not using analgesics, six were taking WHO class III analgesics, 10 class II and 23 class I. Mean MSTS score was 68.1% +/- 23.5% in bone metastasis and 59.6% +/- 17.5% in primary bone tumor. Fourteen patients could walk without assistance, 33 with a single cane, 15 with two canes and eight with a walker; one patient had not been able to resume walking. Discussion: In these indications, dual mobility cups use lead to lower dislocation rates than those reported in the literature. It proved especially effective in the case of bone metastasis and consolidation surgery. In the case of primary bone tumor, it failed to prevent dislocation following acetabular resection, especially when involving the abductor muscles and/or abductor innervation, although it provided lower dislocation rates, comparable to those experienced with other techniques, when applied to limited resection. Level of evidence: IV. Retrospective therapeutic study. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Dislocation of a dual mobility total hip replacement following fracture of the polyethylene liner
    Vedrine, Bertrand
    Guillaumot, Pierre
    Chancrin, Jean-Luc
    [J]. VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (03) : 259 - 264
  • [2] Early intraprosthetic dislocation of a total hip replacement with dual mobility socket: clinical presentation and update review
    Loubignac, Francois
    Felts, Emmanuel
    Allal, Raphael
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 : 85 - 87
  • [3] Early intraprosthetic dislocation of a total hip replacement with dual mobility socket: clinical presentation and update review
    François Loubignac
    Emmanuel Felts
    Raphaël Allal
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 85 - 87
  • [4] EXPERIENCE WITH THE USE OF THE ANGLE BORE SOCKET IN PATIENTS WITH AN INCREASED RISK OF DISLOCATION FOLLOWING TOTAL HIP REPLACEMENT
    Walsh, J.
    Hurson, C.
    Powell, O.
    Synnott, K.
    Quinlan, W.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2007, 176 : S35 - S36
  • [5] Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability
    Guyen, Olivier
    Pibarot, Vincent
    Vaz, Gualter
    Chevillotte, Christophe
    Bejui-Hugues, Jacques
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (02) : 465 - 472
  • [6] The use of dual mobility acetabular cups in total hip replacement reduces dislocation rates in hip dysplasia patients
    Jung Shin Kim
    Nam Hoon Moon
    Min Uk Do
    Sung Won Jung
    Kuen Tak Suh
    Won Chul Shin
    [J]. Scientific Reports, 13
  • [7] The use of dual mobility acetabular cups in total hip replacement reduces dislocation rates in hip dysplasia patients
    Kim, Jung Shin
    Moon, Nam Hoon
    Do, Min Uk
    Jung, Sung Won
    Suh, Kuen Tak
    Shin, Won Chul
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [8] Dislocation Following Total Hip Replacement
    Dargel, Jens
    Oppermann, Johannes
    Brueggemann, Gert-Peter
    Eysel, Peer
    [J]. DEUTSCHES ARZTEBLATT INTERNATIONAL, 2014, 111 (51-52): : 884 - 890
  • [9] Lack of early dislocation following total hip arthroplasty with a new dual mobility acetabular design
    Vigdorchik, Jonathan M.
    D'Apuzzo, Michele R.
    Markel, David C.
    Malkani, Arthur L.
    Raterman, Stephen
    Sharpe, Kipling P.
    Cornell, Charles N.
    Westrich, Geoffrey H.
    [J]. HIP INTERNATIONAL, 2015, 25 (01) : 34 - 38
  • [10] DISLOCATION FOLLOWING TOTAL HIP-REPLACEMENT
    KHAN, MAA
    BRAKENBURY, PH
    REYNOLDS, ISR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1981, 63 (02): : 214 - 218