Multi-slice CT for visualization of acute pulmonary embolism:: Single breath-hold subtraction technique

被引:9
|
作者
Wildberger, JE
Klotz, E
Ditt, H
Mahnken, AH
Spüntrup, E
Günther, RW
机构
[1] Univ Technol, Dept Diagnost Radiol, Aachen, Germany
[2] Siemens Med Solut, Computed Tomog, Forchheim, Germany
关键词
computed tomography (CT); spiral; function; embolism; pulmonary; lung; perfusion; multidetector-row;
D O I
10.1055/s-2004-813875
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and Methods: In three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrastmedium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs(eff) using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5: rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded "compound view" of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: Subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximaiely 24s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries. perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: Our initial results from the animal model studied show that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [1] A limited breath-hold technique for improved image quality in multi-slice PET/CT exams.
    Beyer, T
    Antoch, G
    Freudenberg, L
    Terschueren, B
    Mueller, S
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 274P - 275P
  • [2] Multi-echo, multi-slice, cardiovascular T2* spiral imaging in a single breath-hold
    Nii O Addy
    R Reeve Ingle
    Kenneth O Johnson
    Galen D Reed
    Michelle M Nystrom
    William R Overall
    Juan M Santos
    Bob S Hu
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [3] Multi-slice CT for visualization of pulmonary embolism using perfusion weighted color maps
    Wildberger, JE
    Niethammer, MU
    Klotz, E
    Schaller, S
    Wein, BB
    Günther, RW
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04): : 289 - 294
  • [4] Perfusion-weighted display of multi-slice CT data for visualization of pulmonary embolism
    Niethammer, MU
    Wildberger, JE
    Schoepf, UO
    Klotz, E
    Fichte, H
    Schaller, S
    RADIOLOGY, 2001, 221 : 203 - 203
  • [5] Single breath-hold Vd(m) calculation as good as multi breath-hold technique in Equilibrium Contrast CMR
    Daniel Sado
    Stefan K Piechnik
    Matthew D Robson
    Viviana Maestrini
    Andrew Flett
    Steven K White
    Sanjay M Banypersad
    James Moon
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [6] A new approach to diagnosis of pulmonary embolism using multi-slice CT
    Niethammer, MU
    Schoepf, UJ
    Wildberger, JE
    Klotz, E
    Fichte, H
    Schaller, S
    MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 : 244 - 253
  • [7] Comparison of multi-slice CT and lung perfusion scintigraphy in the diagnosis of pulmonary embolism
    Lang, O.
    Halman, L.
    Penicka, M.
    Kunikova, I.
    Balon, H. R.
    Pichova, R.
    Chroustova, D.
    Knotkova, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S213 - S213
  • [8] Liver: Single breath-hold dynamic subtraction CT with multi-detector row helical technology - Feasibility study
    Spielmann, AL
    Nelson, RC
    Lowry, CR
    Johnson, GA
    Sundaramoothy, G
    Sheafor, DH
    Paulson, EK
    RADIOLOGY, 2002, 222 (01) : 278 - 283
  • [9] Optimizing technique for multi-slice CT
    Sanjay Saini
    Roy V. Dsouza
    European Radiology, 2003, 13 : 21 - 24
  • [10] Optimizing technique for multi-slice CT
    Saini, S
    Dsouza, RV
    EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) : M21 - M24