Estimation of the error in internal target volume (ITV) of lung tumor obtained from free-breathing cine-mode 4DCT: A simulation and comparison study based on dynamic MRI

被引:1
|
作者
Cai, J. [1 ]
Read, P. [1 ]
Baisden, J. [1 ]
Larner, J. [1 ]
Benedict, S. [1 ]
Sheng, K. [1 ]
机构
[1] Univ Virginia, Charlottesville, VA USA
关键词
D O I
10.1118/1.2761752
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantitate the error of tumor internal target volume (ITV) as determined from simulated free‐breathing cine‐mode 4DCT using dynamic magnetic resonance imaging (dMRI). Method and Materials: 8 healthy volunteers and 6 lung tumor patients underwent a 5‐minute MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to simulate the cine‐mode 4DCT acquisition by segmenting and resorting the MR images. Maximum intensity projection (MIP) images were generated from both simulated 4DCT (sCT) and dMRI, and the errors in MIP‐based ITV from sCT (ε), comparing to those from dMRI, were determined and correlate to the subjects' respiratory variability (ν). Results: MIP‐based ITVs from sCT were comparatively smaller than those from dMRI in both digital‐phantom studies (ε=−21.64±8.23%) and lung tumor patient studies (ε=−20.31±11.36%). The errors in MIP‐based ITV from sCT linearly correlated ([formula omitted], r2=0.76) with the subjects' respiratory variability. Conclusions: Because of the low temporal resolution and retrospective resorting, 4DCT may not accurately depict the excursion of a moving tumor. Using 4DCT MIP image to define ITV may therefore cause under‐dosing and increased risk of subsequent treatment failure. Patient‐specific respiratory variability may also be a useful predictor of the 4DCT‐induced error in MIP‐based ITV determination. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2648 / 2648
页数:1
相关论文
共 3 条
  • [1] Comparative Study of Internal Target Volume (ITV) Based on PET-CT and 4DCT for Stereotactic Body Radiotherapy of Non-Small Cell Lung Cancer
    Rahman, S.
    Rahimian, J.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S322 - S322
  • [2] Comparative Study of Internal Target Volume (ITV) Based on PET-CT and 4DCT for Stereotactic Body Radiation Therapy of Non-small Cell Lung Cancer
    Rahman, S.
    Rahimian, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S816 - S816
  • [3] Estimation of error in maximal intensity projection-based internal target volume of lung tumors: A simulation and comparison study using dynamic magnetic resonance imaging
    Cai, Jing
    Read, Paul W.
    Baisden, Joseph M.
    Larner, James M.
    Benedict, Stanley H.
    Sheng, Ke
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : 895 - 902