Purpose: To evaluate by Scheimpflug photography the capacity of several commercially available ophthalmic viscosurgical devices (OVDs) to remain in the anterior chamber and maintain anterior chamber depth (ACD) during simulated cataract surgery in porcine cadaver eyes. Setting: Department of Preclinical Ophthalmology, Pharmacia & Upjohn AB, Uppsala, Sweden. Methods: Eighty eyes from newly slaughtered pigs were used. They were distributed equally among 8 OVDs: Amvisc Plus(R) (sodium hyaluronate 1.6%), Biolon (sodium hyaluronate 1.0%), Biolon Prime (sodium hyaluronate 1.2%), Healon(R) (sodium hyaluronate 1.0%), Healon GV(R) (sodium hyaluronate 1.4%), Healon(R)5 (sodium hyaluronate 2.3%), Provisc(R) (sodium hyaluronate 1.0%), and Viscoat(R) (sodium hyaluronate 3.0%-chondroitin sulfate 4.0%). Scheimpflug photographs were taken using a Nidek EAS-1000 instrument before surgery (control), after injection of the OVD, after continuous curvilinear capsulorhexis (CCC), and after lens extraction by phacoemulsification. Differences in the ACD with a P value less than 0.05 were considered statistically significant. The retention capacity was visually assessed. Results: Healon5 had a significantly higher capacity to maintain the ACD than the other OVDs after CCC and phacoemulsification. After injection, Healon5, Viscoat, and Biolon Prime showed similar ACD-maintaining capacities. Conclusion: The capacity of Healon5 to maintain the ACD during cataract surgery, ie, neutralizing the vitreous pressure and stabilizing the anterior segment of the eye, was significantly higher than that of the other OVDs.
引用
收藏
页码:568 / 574
页数:7
相关论文
共 50 条
  • [1] Impact of Ophthalmic Viscosurgical Devices in Cataract Surgery
    Malvankar-Mehta, Monali S.
    Fu, Angel
    Subramanian, Yasoda
    Hutnik, Cindy
    [J]. JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [2] 3D-Evaluation of Viscoadaptive Ophthalmic Viscosurgical Devices (OVDs) During Cataract Surgery Using the Pentacam Scheimpflug Camera
    Lundgren, B.
    Lundqvist, M.
    Nilsson, S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Effect of incisional friction and ophthalmic viscosurgical devices on the heat generation of ultrasound during cataract surgery
    Floyd, Michael
    Valentine, Jeremy
    Coombs, Jamie
    Olson, Randall J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (07): : 1222 - 1226
  • [4] Femtosecond Laser-Assisted Cataract Surgery Without Ophthalmic Viscosurgical Devices
    Dick, H. Burkhard
    Gerste, Ronald D.
    Rivera, Robert P.
    Schultz, Tim
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (11) : 784 - 787
  • [5] Intraoperative evaluation of phacoemulsification cataract surgery with and without the use of ophthalmic viscosurgical devices
    Joshi, Rajesh Subhash
    Naik, Sanoja Rangnath
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2020, 27 (01) : 47 - 52
  • [6] Ophthalmic viscosurgical devices for intumescent cataracts: Pressure-equalized cataract surgery
    Arshinoff, Steve A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07): : 1549 - 1550
  • [7] Adjunct devices for managing challenging cases in cataract surgery: capsular staining and ophthalmic viscosurgical devices
    Goldman, James M.
    Karp, Carol L.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) : 52 - 57
  • [8] Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery
    Modi, Satish S.
    Davison, James A.
    Walters, Tom
    [J]. CLINICAL OPHTHALMOLOGY, 2011, 5 : 1381 - 1389
  • [9] Ophthalmic viscosurgical devices for intumescent cataracts: Pressure-equalized cataract surgery Reply
    Hengerer, Fritz H.
    Dick, H. Burkhard
    Kohnen, Thomas
    Conrad-Hengerer, Ina
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07): : 1550 - 1551
  • [10] A new histological evaluation method to detect residual ophthalmic viscosurgical devices for cataract surgery
    Mori, Hidetsugu
    Yamada, Haruhiko
    Toyama, Keiko
    Takahashi, Kanji
    [J]. HELIYON, 2018, 4 (09):