Self-Calibration of Angular Position Sensors by Signal Flow Networks

被引:7
|
作者
Gao, Zhenyi [1 ]
Zhou, Bin [1 ]
Hou, Bo [1 ]
Li, Chao [1 ]
Wei, Qi [2 ]
Zhang, Rong [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, Engn Res Ctr Nav Technol, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
关键词
self-calibration; signal flow network; signal processing; angular position sensor; TO-DIGITAL CONVERTER; RESOLVER; AMPLITUDE;
D O I
10.3390/s18082513
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Angle position sensors (APSs) usually require initial calibration to improve their accuracy. This article introduces a novel offline self-calibration scheme in which a signal flow network is employed to reduce the amplitude errors, direct-current (DC) offsets, and phase shift without requiring extra calibration instruments. In this approach, a signal flow network is firstly constructed to overcome the parametric coupling caused by the linearization model and to ensure the independence of the parameters. The model parameters are stored in the nodes of the network, and the intermediate variables are input into the optimization pipeline to overcome the local optimization problem. A deep learning algorithm is also used to improve the accuracy and speed of convergence to a global optimal solution. The results of simulations show that the proposed method can achieve a high identification accuracy with a relative parameter identification error less than 0.001 parts per thousand. The practical effects were also verified by implementing the developed technique in a capacitive APS, and the experimental results demonstrate that the sensor error after signal calibration could be reduced to only 6.98%.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Self-Calibration of Nonlinear Signal Model for Angular Position Sensors by Model-Based Automatic Search Algorithm
    Gao, Zhenyi
    Zhou, Bin
    Hou, Bo
    Li, Chao
    Wei, Qi
    Zhang, Rong
    SENSORS, 2019, 19 (12)
  • [2] A Bilinear Approach to the Position Self-Calibration of Multiple Sensors
    Crocco, Marco
    Del Bue, Alessio
    Murino, Vittorio
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2012, 60 (02) : 660 - 673
  • [3] A self-calibration technique for a smart capacitive angular-position sensor
    Li, XJ
    Meijer, GCM
    deJong, GW
    JOINT CONFERENCE - 1996: IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE & IMEKO TECHNICAL COMMITTEE 7, CONFERENCE PROCEEDINGS, VOLS I AND II: QUALITY MEASUREMENTS: THE INDISPENSABLE BRIDGE BETWEEN THEORY AND REALITY (NO MEASUREMENTS? NO SCIENCE!), 1996, : 774 - 777
  • [4] Self-Calibration for Star Sensors
    Fu, Jingneng
    Lin, Ling
    Li, Qiang
    SENSORS, 2024, 24 (11)
  • [5] Design and Implementation of a System-on-Chip for Self-Calibration of an Angular Position Sensor
    Gao, Zhenyi
    Zhou, Bin
    Li, Chao
    Hou, Bo
    Sun, Haobo
    Wei, Qi
    Zhang, Rong
    APPLIED SCIENCES-BASEL, 2019, 9 (22):
  • [6] Self-calibration of Neural Recording Sensors
    Rodriguez-Perez, Alberto
    Delgado-Restituto, Manuel
    Rodriguez-Vazquez, Angel
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 663 - 666
  • [7] A Position Self-Calibration Method in Multilateration
    Lin Yunsong
    Peng Liangfu
    2017 FORUM ON COOPERATIVE POSITIONING AND SERVICE (CPGPS), 2017, : 101 - 105
  • [8] Self-calibration of precision angle sensors
    Kiyono, Satoshi
    Zhang, Shizhou
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 1994, 60 (11): : 1591 - 1595
  • [9] Self-calibration of sensor networks
    Moses, RL
    Patterson, R
    UNATTENDED GROUND SENSOR TECHNOLOGIES AND APPLICATIONS IV, 2002, 4743 : 108 - 119
  • [10] A Distributed Method for Self-Calibration of Magnetoresistive Angular Position Sensor within a Servo System
    Ceperkovic, Vladimir
    Rajovi, Vladimir
    Prokin, Milan
    SENSORS, 2022, 22 (16)