Comparison of corneal biomechanics after microincision lenticule extraction and small incision lenticule extraction

被引:19
|
作者
Wu, Zhiqing [1 ,2 ,3 ]
Wang, Yan [1 ,2 ]
Zhang, Jiamei [1 ,2 ]
Chan, Tommy C. Y. [4 ,5 ]
Ng, Alex L. K. [6 ]
Cheng, George P. M. [7 ]
Jhanji, Vishal [4 ,5 ,8 ]
机构
[1] Tianjin Med Univ, Tianjin Eye Hosp, Tianjin Key Lab Ophthalmol & Visual Sci, Clin Coll Ophthalmol, Tianjin, Peoples R China
[2] Tianjin Med Univ, Inst Eye, Clin Coll Ophthalmol, Tianjin, Peoples R China
[3] Xian Childrens Hosp, Xian, Peoples R China
[4] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Kowloon, Hong Kong, Peoples R China
[5] Hong Kong Eye Hosp, Dept Ophthalmol, Kowloon, Hong Kong, Peoples R China
[6] Univ Hong Kong, Dept Ophthalmol, Pokfulam, Hong Kong, Peoples R China
[7] Hong Kong Laser Eye Ctr, Hong Kong, Hong Kong, Peoples R China
[8] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
基金
中国国家自然科学基金;
关键词
OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; CATARACT-SURGERY; INTRAOCULAR-PRESSURE; LASIK; MYOPIA; ABERRATIONS; ASTIGMATISM; HYSTERESIS; STANDARD;
D O I
10.1136/bjophthalmol-2016-308636
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives To evaluate and compare the change in corneal biomechanical properties after microincision lenticule extraction (MILE) and small incision lenticule extraction (SMILE). Methods In this prospective study, 60 eyes received MILE surgery with 2 mm opening incision, while 64 eyes received SMILE procedure with 5 mm opening incision. Corneal hysteresis (CH), corneal resistance factor (CRF) and 37 other biomechanical waveform parameters were quantitatively assessed using ocular response analyser (ORA) preoperatively and up to 6 months postoperatively. All changes were calculated as the difference between preoperative and postoperative values (Delta). Results Both CH and CRF values decreased significantly after MILE and SMILE (p<0.001). Delta CRF (o=0.028) and Delta CRF index (Delta CRF/preoperative CRF) (p=0.043) were statistically lower for all eyes at 1-week follow-up. Delta CH index (Delta CH/preoperative CH) was statistically lower at 1-week (p=0.043) and 1-month (p=0.015) follow-ups in MILE group when compared with SMILE group. In both MILE and SMILE group, Delta CH index and Delta CRF index were positively correlated with preoperative manifest refraction spherical equivalent, residual stromal thickness (RST) index (RST/preoperative central corneal thickness) and negatively correlated with lenticule thickness (p<0.05). Conclusions Both MILE and SMILE procedures significantly altered the biomechanical characteristics of cornea. Smaller opening incision was associated with less reduction in ORA parameters during early postoperative period.
引用
收藏
页码:650 / 654
页数:5
相关论文
共 50 条
  • [1] Intraindividual comparison of changes in corneal biomechanical parameters after femtosecond lenticule extraction and small-incision lenticule extraction
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Kobashi, Hidenaga
    Sato, Nobuyuki
    Ishii, Rie
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (06): : 963 - 970
  • [2] Corneal Lenticule Allotransplantation After Femtosecond Laser Small Incision Lenticule Extraction in Rabbits
    Zhao, Jing
    Shen, Yang
    Tian, Mi
    Sun, Ling
    Zhao, Yu
    Zhang, Xiaoyu
    Zhou, Xingtao
    [J]. CORNEA, 2017, 36 (02) : 222 - 228
  • [3] Corneal opacities after small-incision lenticule extraction
    Hjortdal, Jesper
    Daya, Sheraz
    Kim, Eung Kweon
    Sekundo, Walter
    Ganesh, Sri
    Brar, Sheetal
    Moshirfar, Majid
    Hansen, Annika M.
    Payne, Carter J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (09): : 1097 - 1100
  • [4] Intraocular pressure changes and corneal biomechanics after hyperopic small-incision lenticule extraction
    Fu, Dan
    Li, Meiyan
    Knorz, Michael C.
    Wei, Shengsheng
    Shang, Jianmin
    Zhou, Xingtao
    [J]. BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [5] Intraocular pressure changes and corneal biomechanics after hyperopic small-incision lenticule extraction
    Fu, Dan
    Zhou, Xingtao
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [6] Comparison of immediate small-incision lenticule extraction after suction loss with uneventful small-incision lenticule extraction
    Park, Jin Hyoung
    Koo, Hyung Jin
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (04): : 466 - 472
  • [7] Intraocular pressure changes and corneal biomechanics after hyperopic small-incision lenticule extraction
    Dan Fu
    Meiyan Li
    Michael C. Knorz
    Shengsheng Wei
    Jianmin Shang
    Xingtao Zhou
    [J]. BMC Ophthalmology, 20
  • [8] Corneal densitometric outcomes of small incision lenticule extraction
    Quach, Wendy
    Viswanathan, Deepa
    Males, John J.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 950 - 951
  • [9] Corneal Sensation After Corneal Refractive Surgery with Small Incision Lenticule Extraction
    Demirok, Ahmet
    Ozgurhan, Engin Bilge
    Agca, Alper
    Kara, Necip
    Bozkurt, Ercument
    Cankaya, Kadir Ilker
    Yilmaz, Omer Faruk
    [J]. OPTOMETRY AND VISION SCIENCE, 2013, 90 (10) : 1040 - 1047
  • [10] Longitudinal evaluation of corneal tomography after small incision lenticule extraction
    Vannarut Satitpitakul
    Patraramon Chotikkakamthorn
    Jirat Suwanwatana
    Ngamjit Kasetsuwan
    Vilavun Puangsricharern
    Usanee Reinprayoon
    [J]. Eye, 2023, 37 : 373 - 374