Multielemental Determination of As, Bi, Ge, Sb, and Sn in Agricultural Samples Using Hydride Generation Coupled to Microwave-Induced Plasma Optical Emission Spectrometry

被引:23
|
作者
Machado, Raquel C. [1 ,2 ]
Amaral, Clarice D. B. [3 ]
Nobrega, Joaquim A. [1 ]
Araujo Nogueira, Ana Rita [2 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, BR-13565905 Sao Carlos, SP, Brazil
[2] Embrapa Pecuaria Sudeste, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Fed Parana, Dept Chem, BR-81531980 Curitiba, PR, Brazil
基金
巴西圣保罗研究基金会;
关键词
simultaneous hydride generation; microwave-induced plasma; HG-MIP OES; nitrogen plasma and complex samples; ATOMIC SPECTROMETRY; SONICATE SLURRIES; HG; ELEMENTS; SE;
D O I
10.1021/acs.jafc.7b01448
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A microwave-induced plasma optical emission spectrometer with N-2-based plasma was combined with a multimode sample introduction system (MSIS) for hydride generation (HG) and Multielemental determination of As, Bi, Ge, and Sn in samples of forage, bovine liver, powdered milk, agricultural gypsum, rice,,and mineral fertilizer, using a single condition of prereduction and reduction. The accuracy of the developed analytical method was evaluated using certified reference materials of water and mineral fertilizer, and recoveries ranged from 95 to 106%. Addition and recovery experiments were carried out, and the recoveries varied from 85 to 117% for all samples evaluated. The limits of detection for As, Bi, Ge, Sb, and Sn were 0.46, 0:09, 0.19, 0.46, and 5.2 mu g/L, respectively, for liquid samples, and 0.18, 0.04, 0.08, 0.19, and 2.1 mg/kg, respectively, for solid samples. The method proposed offers a simple, fast, multielemental; and robust alternative for successful determination of all five analytes in agricultural samples with low operational cost without compromising analytical performance.
引用
收藏
页码:4839 / 4842
页数:4
相关论文
共 50 条
  • [1] DETERMINATION OF GE, AS, SE, SN AND SB IN BIOLOGICAL SAMPLES UTILIZING HYDRIDE GENERATION CHROMATOGRAPHICALLY COUPLED TO A MICROWAVE INDUCED AR-HE PLASMA
    ROBBINS, WB
    CARUSO, JA
    FRICKE, FL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 175 (MAR): : 41 - 41
  • [2] Determination of toxicological relevant arsenic species in urine by hydride generation microwave-induced plasma optical emission spectrometry
    Pizzorno, Paulina
    Falchi, Lucia
    Manay, Nelly
    Piston, Mariela
    Buhl, Valery
    METHODSX, 2024, 13
  • [3] Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry - comparison with inductively coupled plasma optical emission spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Ponta, Michaela
    Darvasi, Eugen
    Senila, Marin
    Petreus, Dorin
    Frentiu, Maria
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (10) : 1880 - 1888
  • [4] Optimization of electrochemical hydride generation coupled to microwave-induced plasma atomic emission spectrometry for the determination of arsenic and its use for the analysis of biological tissue samples
    Schickling, C
    Yang, JF
    Broekaert, JAC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 739 - 745
  • [5] Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry-comparison with inductively coupled plasma optical emission spectrometry
    20143900072302
    Frentiu, Tiberiu, 1880, Royal Society of Chemistry (29):
  • [6] Greening Ultrasound-Assisted Extraction for Sorghum Flour Multielemental Determination by Microwave-Induced Plasma Optical Emission Spectrometry
    Isabel Curti, Maria
    Cora Jofre, Florencia
    Azcarate, Silvana M.
    Camina, Jose M.
    Ribotta, Pablo D.
    Savio, Marianela
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2021, 2021
  • [7] DETERMINATION OF GERMANIUM, ARSENIC, SELENIUM, TIN AND ANTIMONY IN COMPLEX SAMPLES BY HYDRIDE GENERATION - MICROWAVE-INDUCED PLASMA ATOMIC-EMISSION SPECTROMETRY
    ROBBINS, WB
    CARUSO, JA
    FRICKE, FL
    ANALYST, 1979, 104 (1234) : 35 - 40
  • [8] Study of chemical and spectral interferences in the simultaneous determination of As, Bi, Sb, Se and Sn by hydride generation inductively coupled plasma atomic emission spectrometry
    Pohl, P
    Zyrnicki, W
    ANALYTICA CHIMICA ACTA, 2002, 468 (01) : 71 - 79
  • [9] Optimization of electrochemical hydride generation in a miniaturized electrolytic flow cell coupled to microwave-induced plasma atomic emission spectrometry for the determination of selenium
    S. Schermer
    L. Jurica
    J. Paumard
    E. Beinrohr
    F.-M. Matysik
    J. Broekaert
    Fresenius’ Journal of Analytical Chemistry, 2001, 371 : 740 - 745
  • [10] Optimization of electrochemical hydride generation in a miniaturized electrolytic flow cell coupled to microwave-induced plasma atomic emission spectrometry for the determination of selenium
    Schermer, S
    Jurica, L
    Paumard, J
    Beinrohr, E
    Matysik, FM
    Broekaert, JAC
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (06): : 740 - 745