Computerized 3D morphological analysis of glenoid orientation

被引:16
|
作者
Ghafurian, Soheil [1 ]
Galdi, Balazs [2 ]
Bastian, Sevag [2 ]
Tan, Virak [2 ]
Li, Kang [1 ,2 ,3 ,4 ,5 ]
机构
[1] Rutgers State Univ, Dept Ind & Syst Engn, Piscataway, NJ USA
[2] Rutgers State Univ, Sch Med, Dept Orthopaed, Newark, NJ 07102 USA
[3] Rutgers State Univ, Dept Comp Sci, Piscataway, NJ USA
[4] Rutgers State Univ, Dept Biomed Engn, Piscataway, NJ USA
[5] Univ Elect Sci & Technol China, Sch Mech Engn, Chengdu 610054, Peoples R China
基金
美国国家科学基金会;
关键词
glenoid orientation; fulcrum axis; version; inclination; morphometry; SURGICAL TECHNIQUE; PROSTHETIC DESIGN; TOMOGRAPHY SCANS; FULCRUM AXIS; VERSION; ANATOMY; SEGMENTATION; RADIOGRAPHS; SHOULDER; SCAPULA;
D O I
10.1002/jor.23053
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
An accurate preoperative measurement of glenoid orientation is crucial for evaluating pathologies and successful total shoulder arthroplasty. Existing methods may be labor-intensive, observer-dependent, and sensitive to the misalignment between the scapula plane and CT scanning direction. In this study, we proposed a computation framework and performed an automated analysis of the glenoid orientation based on 3D surface data. Three-dimensional models of 12 scapulae were analyzed. The glenoid cavity and external anatomical features were automatically extracted from these 3D models. Glenoid version was calculated using the scapula plane and the fulcrum axis alternatively. Glenoid inclination was measured both relative to transverse axis of the scapula and the medial pole-inferior tip axis. The mean (+/- SD) of the fulcrum-based glenoid version was -0.55 degrees (+/- 4.17 degrees), while the scapular-plane-based glenoid version was -5.05 degrees (+/- 3.50 degrees). The mean (+/- SD) of glenoid inclinations based on the medial pole and inferior tip was 12.75 degrees (+/- 5.03 degrees) while the mean (+/- SD) of the glenoid inclination based on the medial pole and glenoid center was 4.63 degrees (+/- 4.86 degrees). Our computational framework was able to extract the reproducible morphological measures free of inter- and intra- observer variability. For the first time in 3D, we showed that the fulcrum axis was practically perpendicular to the glenoid plane normal (radial line), and thus extended the fulcrum-based glenoid version for quantifying 3D glenoid orientation. (c) 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:692-698, 2016.
引用
收藏
页码:692 / 698
页数:7
相关论文
共 50 条
  • [1] Morphological and mechanical analysis of the glenoid by 3D geometric reconstruction using computed tomography
    Couteau, B
    Mansat, P
    Darmana, R
    Mansat, M
    Egan, J
    [J]. CLINICAL BIOMECHANICS, 2000, 15 : S8 - S12
  • [2] 3D morphological analysis of Arabidopsis sepals
    He, Xi
    Xu, Shouling
    Hong, Lilan
    [J]. PLANT CELL BIOLOGY, 2020, 160 : 311 - 326
  • [3] 3D morphological analysis of lung pathology
    Zavaletta, Vanessa A.
    Bartholmai, Brian J.
    Robb, Richard A.
    [J]. 2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 308 - 311
  • [4] SAMA: A Method for 3D Morphological Analysis
    Paulose, Tessie
    Montevil, Mael
    Speroni, Lucia
    Cerruti, Florent
    Sonnenschein, Carlos
    Soto, Ana M.
    [J]. PLOS ONE, 2016, 11 (04):
  • [5] MORPHOLOGICAL ANALYSIS OF 3D PROTEINS STRUCTURE
    Cantoni, Virginio
    Gatti, Riccardo
    Lombardi, Luca
    [J]. BIOINFORMATICS 2011, 2011, : 15 - 21
  • [6] Comparison of Glenoid Dimensions Between 3D Computed Tomography and 3D Printing
    Yiannakopoulos, Christos
    Vlastos, Iakovos
    Koutserimpas, Christos
    Gianzina, Elina
    Dellis, Spilios
    Kalinterakis, Georgios
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [7] Computerized analysis of pelvic incidence from 3D images
    Vrtovec, Tomaz
    Janssen, Michiel M. A.
    Pernus, Franjo
    Castelein, Rene M.
    Viergever, Max A.
    [J]. MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [8] Computerized analysis of lesions in 3D MR breast images
    Wang, H
    Zheng, B
    Good, WF
    Wang, XH
    [J]. MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1751 - 1762
  • [9] Improvement of tumor volume analysis with computerized 3D techniques
    Vining, DJ
    Sloan, TC
    Honea, D
    Ge, Y
    Stelts, DR
    Bechtold, RE
    [J]. RADIOLOGY, 1996, 201 : 649 - 649
  • [10] 3D laser imaging for joint orientation analysis
    Mah, Jason
    Samson, Claire
    McKinnon, Stephen D.
    [J]. INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2011, 48 (06) : 932 - 941