Advantages of Extended Brain Perfusion Computed Tomography 9.6 cm Coverage With Time Resolved Computed Tomography-Angiography in Comparison to Standard Stroke-Computed Tomography

被引:32
|
作者
Morhard, Dominik [1 ]
Wirth, Christina D.
Fesl, Gunther [1 ]
Schmidt, Caroline [2 ]
Reiser, Maximilian F.
Becker, Christoph R.
Ertl-Wagner, Birgit
机构
[1] Univ Munich, Inst Clin Radiol, Dept Neuroradiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Neurol, D-81377 Munich, Germany
关键词
(MeSH); cerebral angiography; computed tomography; perfusion; stroke; ACUTE STROKE PATIENTS; TOGGLING-TABLE TECHNIQUE; QUANTITATIVE ASSESSMENT; CEREBRAL-ISCHEMIA; CT-ANGIOGRAPHY; DYNAMIC CT; EXPERIENCE; VOLUME;
D O I
10.1097/RLI.0b013e3181e1956f
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Recent technical developments have led to an extension of perfusion computed tomography (PCT) scan range to cover nearly the entire brain and to reconstruct time resolved (4d) CT-angiography (CTA) datasets from the PCT data. The purpose of this study was to compare the results of simulated standard PCT and extended PCT with 4d-CTA. Materials and Methods: Extended multimodal stroke CT (unenhanced cranial CT, CTA, and PCT) was acquired in 72 patients. PCT images with a scan coverage of 9.6 cm in the z-axis, simulated 2 cm PCT images at the level of the basal ganglia comparable to standard PCT, standard supra-aortic CTA, and 4d-CTA images were reconstructed. Two readers assessed the PCT image quality as well as pathologic findings in extended and simulated PCT, CTA, and 4d-CTA. The brain was divided into 4 axial segments. The independent samples t test was applied to test differences between data for significance. Results: In 75.0% of all patient exams, pathologic findings were observed in the PCT; these were located in 138 brain segments. In 24.1% of all 54 exams with pathologic PCT findings, the pathology would have been missed on standard PCT. The longer scan coverage resulted in a different final diagnosis in 34.7% of all exams. Quality of the PCT parameter maps was on average very good both for the supratentoric and the infratentoric brain areas (4.28 and 4.18, respectively, on a 5-point scale). In 90% of all exams with pathologic changes in the CTA, these abnormalities were also noted on 4d-CTA. In only 2.8% of all cases, the additional time resolution of the 4d-CTA provided additional information. Conclusion: Extending the scan coverage of PCT from 2 cm to 9.6 cm led to an augmentation of clinically important information in the imaging of acute stroke.
引用
收藏
页码:363 / 369
页数:7
相关论文
共 50 条
  • [1] Computed Tomography, Computed Tomography Angiography, and Perfusion Computed Tomography Evaluation of Acute Ischemic Stroke
    Leiva-Salinas, Carlos
    Jiang, Bin
    Wintermark, Max
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2018, 28 (04) : 565 - 572
  • [2] Collateral Status in Ischemic Stroke: A Comparison of Computed Tomography Angiography, Computed Tomography Perfusion, and Digital Subtraction Angiography
    Kauw, Frans
    Dankbaar, Jan W.
    Martin, Blake W.
    Ding, Victoria Y.
    Boothroyd, Derek B.
    van Ommen, Fasco
    de Jong, Hugo W. A. M.
    Kappelle, L. Jaap
    Velthuis, Birgitta K.
    Heit, Jeremy J.
    Wintermark, Max
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (06) : 984 - 992
  • [3] Computed Tomography Perfusion is aUseful Adjunct to Computed Tomography Angiography in the Diagnosis of Brain Death
    Sawicki, M.
    Solek-Pastuszka, J.
    Chamier-Cieminska, K.
    Walecka, A.
    Walecki, J.
    Bohatyrewicz, R.
    CLINICAL NEURORADIOLOGY, 2019, 29 (01) : 101 - 108
  • [4] Computed Tomography Perfusion is a Useful Adjunct to Computed Tomography Angiography in the Diagnosis of Brain Death
    M. Sawicki
    J. Sołek-Pastuszka
    K. Chamier-Ciemińska
    A. Walecka
    J. Walecki
    R. Bohatyrewicz
    Clinical Neuroradiology, 2019, 29 : 101 - 108
  • [5] Postmortem-computed tomography and postmortem-computed tomography-angiography: a focused update
    Busardo, Francesco Paolo
    Frati, Paola
    Guglielmi, Giuseppe
    Grilli, Giampaolo
    Pinto, Antonio
    Rotondo, Antonio
    Panebianco, Valeria
    Fineschi, Vittorio
    RADIOLOGIA MEDICA, 2015, 120 (09): : 810 - 823
  • [6] CT Imaging Computed Tomography/Computed Tomography Angiography/ Perfusion in Acute Ischemic Stroke and Vasospasm
    Panicker, Sreehari
    Wilseck, Zachary M.
    Lin, Leanne Y.
    Gemmete, Joseph J.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2024, 34 (02) : 175 - 189
  • [7] Computed Tomography Angiography and Myocardial Computed Tomography Perfusion in Patients With Coronary Stents
    Rief, Matthias
    Zimmermann, Elke
    Stenzel, Fabian
    Martus, Peter
    Stangl, Karl
    Greupner, Johannes
    Knebel, Fabian
    Kranz, Anisha
    Schlattmann, Peter
    Laule, Michael
    Dewey, Marc
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (16) : 1476 - 1485
  • [8] Computed tomography perfusion and computed tomography angiography in vasospasm after subarachnoid hemorrhage
    Stecco, Alessandro
    Fabbiano, Francesco
    Amatuzzo, Paola
    Quagliozzi, Martina
    Soligo, Eleonora
    Divenuto, Ignazio
    Panzarasa, Gabriele
    Carriero, Alessandro
    JOURNAL OF NEUROSURGICAL SCIENCES, 2018, 62 (04) : 397 - 405
  • [9] Computed tomography angiography and perfusion imaging of acute stroke
    Hunter, G
    Hamberg, L
    Lev, MH
    González, RG
    CEREBRAL BLOOD FLOW: MECHANISMS OF ISCHEMIA, DIAGNOSIS AND THERAPY, 2002, 37 : 165 - 178
  • [10] Time dependence of reliability of noncontrast computed tomography in comparison to computed tomography angiography source image in acute ischemic stroke
    Bal, Simerpreet
    Bhatia, Rohit
    Menon, Bijoy K.
    Shobha, Nandavar
    Puetz, Volker
    Dzialowski, Imanuel
    Modi, Jayesh
    Goyal, Mayank
    Hill, Michael D.
    Smith, Eric E.
    Demchuk, Andrew M.
    INTERNATIONAL JOURNAL OF STROKE, 2015, 10 (01) : 55 - 60