We have designed FlexToT, a flexible application specific integrated circuit (ASIC) using time-over-threshold (ToT) techniques for the readout of silicon photomultiplier (SiPM) arrays in positron emission tomography (PET) detectors. The FlexToT ASIC accommodates 16 independent channels in a small die size (2.93 mm by 2.54 mm) with low power consumption (10 mW per channel), providing output signals whose duration is proportional to the current amplitude at its inputs. The threshold, gain and other parameters can be independently set for each channel in a flexible configuration that can be tailored to different applications and devices. Herein we present the results on the evaluation of the FlexToT ASIC operating as front-end electronics for SiPM arrays S11828-3344M from Hamamatsu (Japan) coupled to LYSO:Ce scintillators in a simple PET tomograph demonstrator. Each detector block is composed of a LYSO:Ce matrix coupled to 4 SiPM arrays in a 2x2 mosaic, totaling 64 pixels (8x8) which are read out by 4 FlexToT ASICs. Using this demonstrator we have obtained PET images of Na-22 point sources with spatial resolutions better than 2 mm full width at half maximum (FWHM), validating our design of the FlexToT ASIC on the readout of SiPM matrices and scintillators in PET applications.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] FlexToT - Current Mode ASIC for Readout of Common Cathode SiPM arrays
    Comerma, Albert
    Gascon, David
    Freixas, Lluis
    Garrido, Lluis
    Graciani, Ricardo
    Marin, Jesus
    Martinez, Gustavo
    Manuel Perez, Jose
    Rato Mendes, Pedro
    Castilla, Javier
    Manuel Cela, Jose
    Maria Fernandez-Varea, Jose
    Sarasola, Iciar
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] Performance of the FlexToT v2 ASIC on the Readout of Different Detector Designs for PET
    Cela, Jose M.
    Fernandez-Varea, Jose M.
    Freixas, Lluis
    Garrido, Lluis
    Gascon, David
    Graciani, Ricardo
    Marin, Jesus
    Martinez, Gustavo
    Mauricio, Joan
    Oller, Juan C.
    Perez, Jose M.
    Rato-Mendes, Pedro
    Sanchez, David
    Sanuy, Andreu
    Sarasola, Iciar
    de la Torre, Oscar
    Vela, Oscar
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] An ASIC for SiPM/MPPC Readout
    Meier, Dirk
    Mikkelsen, Sindre
    Talebi, Jahanzad
    Azman, Suleyman
    Maehlum, Gunnar
    Patt, Bradley E.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1653 - 1657
  • [4] ASIC development for SiPM readout
    Corsi, Francesco
    Foresta, Maurizio
    Marzocca, Cristoforo
    Matarrese, Gianvito
    Del Guerra, Alberto
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [5] GAMMA: a High Dynamic Range 16-ch ASIC for Large Scintillators Readout with SiPM Array
    Buonanno, L.
    Montagnani, G. L.
    Di Vita, D.
    Castelli, F.
    Carminati, M.
    Fiorini, C.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [6] Front End ASIC design for SiPM readout
    Comerma, A.
    Gascon, D.
    Garrido, L.
    Delgado, C.
    Marin, J.
    Perez, J. M.
    Martinez, G.
    Freixas, L.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [7] An FPGA based DAQ System for the Readout of SiPM Matrices in PET Applications
    Bisogni, M. G.
    Collazuol, G.
    Del Guerra, A.
    Llosa, G.
    Magazzu, G.
    Marcatili, S.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2447 - +
  • [8] A SiPM-Readout ASIC for SPECT Applications
    Trigilio, Paolo
    Busca, Paolo
    Quaglia, Riccardo
    Occhipinti, Michele
    Fiorini, Carlo
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (05) : 404 - 410
  • [9] Performance evaluation of scintillators for SiPM PET/MRI Brain Imaging
    Rivera, N. Campos
    Seitz, B.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S771 - S771
  • [10] PACIFIC: SiPM readout ASIC for LHCb upgrade
    Mazorra de Cos, Jose
    Chanal, Herve
    Montells, Albert Comerma
    Gascon Fora, David
    Gomez Fernandez, Sergio
    Han, Xiaoxue
    Pillet, Nicolas
    Vandaelle, Richard
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 354 - 358