Comparison between mechanical stress and bone mineral density in the femur after total hip arthroplasty by using subject-specific finite element analyses

被引:24
|
作者
Ike, Hiroyuki [1 ]
Inaba, Yutaka [1 ]
Kobayashi, Naomi [1 ]
Hirata, Yasuhide [1 ]
Yukizawa, Yohei [1 ]
Aoki, Chie [1 ]
Choe, Hyonmin [1 ]
Saito, Tomoyuki [1 ]
机构
[1] Yokohama City Univ, Dept Orthopaed Surg, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
关键词
total hip arthroplasty; finite element analysis; bone mineral density; PROXIMAL FEMUR; FEMORAL STEMS; STRAIN DISTRIBUTION; FOLLOW-UP; REPLACEMENT; CT; MODELS; SIMULATION; PREDICTION; STRENGTH;
D O I
10.1080/10255842.2013.869320
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The mechanism underling bone mineral density (BMD) loss that occurs in the femur after total hip arthroplasty (THA) remains unknown. We compared the equivalent stress and strain energy density (SED) to BMD in the femur after THA using subject-specific finite element analyses. Twenty-four patients who had undergone primary cementless THA were analysed. BMD was measured using dual-energy X-ray absorptiometry (DEXA) at 1 week and 3, 6 and 12 months after THA. Seven regions of interest (ROIs) were defined in accordance with Gruen's system (ROIs 1-7). Computed tomography images of the femurs were acquired pre- and postoperatively, and the images were converted into three-dimensional finite element (FE) models. Equivalent stress and SED were analysed and compared with DEXA data. BMD was maintained 1 year after THA in ROIs 3, 4, 5 and 6, whereas BMD decreased in ROIs 1, 2 and 7. FE analysis revealed that equivalent stress in ROIs 3, 4, 5 and 6 was much higher than that in ROIs 1, 2 and 7. A significant correlation was observed between the rate of changes in BMD and equivalent stress. Reduction of equivalent stress may contribute to decrease in BMD in the femur after THA.
引用
收藏
页码:1056 / 1065
页数:10
相关论文
共 50 条
  • [1] Relation between subject-specific hip joint loading, stress distribution in the proximal femur and bone mineral density changes after total hip replacement
    Jonkers, Ilse
    Sauwen, Nicolas
    Lenaerts, Gerlinde
    Mulier, Michiel
    Van der Perre, Georges
    Jaecques, Siegfried
    JOURNAL OF BIOMECHANICS, 2008, 41 (16) : 3405 - 3413
  • [2] Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty
    Wilkinson, JM
    Peel, NFA
    Elson, RA
    Stockley, I
    Eastell, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (02): : 283 - 288
  • [3] Risk analysis of patients with an osteolytic acetabular defect after total hip arthroplasty using subject-specific finite-element modelling
    Munro, J. T.
    Millar, J. S.
    Fernandez, J. W.
    Walker, C. G.
    Howie, D. W.
    Shim, V. B.
    BONE & JOINT JOURNAL, 2018, 100B (11): : 1455 - 1462
  • [4] Bone density at the proximal femur after total hip arthroplasty
    Kröger, H
    Venesmaa, P
    Jurvelin, J
    Miettinen, H
    Suomalainen, O
    Alhava, E
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (352) : 66 - 74
  • [5] Changes in Bone Mineral Density of the Acetabulum and Proximal Femur After Total Hip Resurfacing Arthroplasty
    Huang, Qiang
    Shen, Bin
    Yang, Jing
    Zhou, Zong-ke
    Kang, Peng-de
    Pei, Fu-xing
    JOURNAL OF ARTHROPLASTY, 2013, 28 (10): : 1811 - 1815
  • [6] Total hip arthroplasty by using a cementless ultrashort stem: A subject-specific finite element analysis for a young patient clinical case
    Epasto, Gabriella
    Foti, Albina
    Guglielmino, Eugenio
    Rosa, Michele A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (07) : 757 - 766
  • [7] Subject-specific musculoskeletal modelling in patients before and after total hip arthroplasty
    Wesseling, Mariska
    De Groote, Friedl
    Meyer, Christophe
    Corten, Kristoff
    Simon, Jean-Pierre
    Desloovere, Kaat
    Jonkers, Ilse
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (15) : 1683 - 1691
  • [8] Periprosthetic bone mineral density of the distal femur after total knee arthroplasty
    Liu, TK
    Yang, RS
    Chieng, PU
    Shee, BW
    INTERNATIONAL ORTHOPAEDICS, 1995, 19 (06) : 346 - 351
  • [9] Changes in bone mineral density of the proximal femur after total knee arthroplasty
    Ishii, Y
    Yagisawa, K
    Ikezawa, Y
    JOURNAL OF ARTHROPLASTY, 2000, 15 (04): : 519 - 522
  • [10] Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis
    Takaki Miyagawa
    Kazu Matsumoto
    Shingo Komura
    Haruhiko Akiyama
    BMC Musculoskeletal Disorders, 22