Monitoring of cerebral oxygen metabolism in the jugular bulb: Reliability of unilateral measurements in severe head injury

被引:46
|
作者
Metz, C
Holzschuh, M
Bein, T
Woertgen, C
Rothoerl, R
Kallenbach, B
Taeger, K
Brawanski, A
机构
[1] Univ Regensburg, Dept Anesthesiol, D-8400 Regensburg, Germany
[2] Univ Regensburg, Dept Neurosurg, D-8400 Regensburg, Germany
来源
关键词
bilateral; cerebral ischemia; head injury; jugular bulb; jugular venous monitoring; lactate;
D O I
10.1097/00004647-199803000-00012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate the reliability of unilateral jugular venous monitoring and to determine the appropriate side, we performed bilateral jugular venous monitoring in 22 head-injured patients. Fiberoptic catheters were placed in both jugular bulbs. Arterial and bilateral jugular venous blood samples were obtained simultaneously for in vitro determination of jugular venous oxygen saturation (SJO(2)), arterial minus jugular venous lactate content difference (AJDL), and modified lactate-oxygen index (mLOI). Ischemia was assumed if one of the following pathologic values occurred at least unilaterally: SJO(2) <54%, AJDL < -0.37 mmol/L, mLOI > 0.08. The sensitivity of calculated unilateral monitoring in detecting ischemia was evaluated by comparing the incidence detected unilaterally with that disclosed bilaterally. The mean and maximum bilateral SJO(2) differences varied between 1.4% and 21.0%, and 8.1% and 44.3%, respectively. The bias and limits of agreement (mean differences +/- 2 SD) between paired samples were 0.4% +/- 12.8%. There was no significant variation in bilateral SJO(2) differences with time. Decreasing cerebral perfusion pressure (r = -0.559, P < 0.001) and arterial PCO2 (r = -0.342, P < 0.001) were associated with increasing bilateral SJO(2) differences. Regarding AJDL, the maximum bilateral differences varied between 0.04 mmol/L and 1.52 mmol/L. The bias and limits of agreement were -0.01 +/- 0.18 mmol/L. At best, 87% of ischemic events were disclosed by monitoring on the side of predominant lesion or, in diffuse injuries, on the side of the larger jugular foramen (computed tomographic [CT] approach). We conclude that in severe head injury, even calculated unilateral jugular venous monitoring has an unpredictable risk for misleading or missing data. Therefore, the reliability of unilateral jugular venous monitoring appears suspicious. For diagnosing ischemia the CT approach is recommended.
引用
收藏
页码:332 / 343
页数:12
相关论文
共 50 条
  • [1] Jugular bulb monitoring of cerebral oxygen metabolism in severe head injury: Accuracy of unilateral measurements
    Metz, C
    Holzschuh, M
    Bein, T
    Kallenbach, B
    Taeger, K
    INTRACRANIAL PRESSURE AND NEUROMONITORING IN BRAIN INJURY, 1998, 71 : 324 - 327
  • [2] Clinical usefulness of jugular bulb oxygen saturation monitoring in severe head injury patients
    Roig, AJB
    Marquez, MP
    Sant, LM
    Bak, E
    Cervera, GR
    Noguera, JB
    Castel, AN
    Gich, I
    NEUROCIRUGIA, 1998, 9 (03): : 232 - 236
  • [3] Cerebral oxygen metabolism in severe head injury
    Kushi, H
    Saito, T
    Hayashi, N
    ICRAN 99: INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN NEUROTRAUMATOLOGY, 1999, : 229 - 232
  • [4] Jugular bulb oximetry: the link between cerebral and systemic management of severe head injury
    De Deyne, C
    INTENSIVE CARE MEDICINE, 1999, 25 (05) : 430 - 431
  • [5] Jugular bulb oximetry: the link between cerebral and systemic management of severe head injury
    C. De Deyne
    Intensive Care Medicine, 1999, 25 : 430 - 431
  • [6] Jugular bulb hemoglobin oxygen saturation is not a standard for comparison with cerebral oximetry in head injury
    Nemoto, EM
    ANESTHESIOLOGY, 2000, 92 (06) : 1847 - 1847
  • [8] Analysis of abnormal jugular bulb oxygen saturation data in patients with severe head injury
    deDeyne, C
    Vandekerckhove, T
    Decruyenaere, J
    Colardyn, F
    ACTA NEUROCHIRURGICA, 1996, 138 (12) : 1409 - 1415
  • [9] Jugular bulb oximetry for the monitoring of cerebral blood flow and metabolism
    Mayberg, TS
    Lam, AM
    NEUROSURGERY CLINICS OF NORTH AMERICA, 1996, 7 (04) : 755 - +
  • [10] Limits of intermittent jugular bulb oxygen saturation monitoring in the management of severe head trauma patients
    Latronico, N
    Beindorf, AE
    Rasulo, FA
    Febbrari, P
    Stefini, R
    Cornali, C
    Candiani, A