A Mediated Glucose Biosensor Incorporated with Reverse Iontophoresis Function for Noninvasive Glucose Monitoring

被引:16
|
作者
Ching, Congo Tak-Shing [1 ,2 ]
Sun, Tai-Ping [1 ,2 ]
Huang, Su-Hua [3 ]
Shieh, Hsiu-Li [2 ]
Chen, Chung-Yuan [2 ]
机构
[1] Natl Chi Nan Univ, Grad Inst Biomed & Biomed Technol, Puli 54561, Nantou County, Taiwan
[2] Natl Chi Nan Univ, Dept Elect Engn, Puli 54561, Nantou County, Taiwan
[3] Asia Univ, Dept Biotechnol, Wufeng 41354, Taichung County, Taiwan
关键词
Amperometric; Ferrocene; Glucose; Biosensors; Reverse Iontophoresis; AMPEROMETRIC ENZYME ELECTRODE; GLUCOWATCH BIOGRAPHER; ASCORBIC-ACID; IN-VIVO; FERROCENE; OXIDASE; DESIGN; FLOW; TETRATHIAFULVALENE; COMPOSITE;
D O I
10.1007/s10439-010-9918-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to develop a ferrocene mediated glucose biosensor for reverse iontophoresis. An amperometric ferrocene mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique. Different combinations of glucose oxidase and ferrocene loading were drop coated onto the surface of the amperometric transducer. The amperometric transducer was characterized electrochemically using cyclic voltammetry and its electrochemical characteristics (Delta E (p) = 70 mV, I (pa)/I (pc) = 0.89) were found close to an ideal amperometric transducer. The biosensor on the detection of glucose at 200 mV (vs. Ag/AgCl) showed a linear response range (0-4 mM). The response time of the biosensor was about 10 s. Finally, the biosensor was used together with reverse iontophoresis technique. By the use of an actual model for evaluation, an excellent linear relationship (r (2) = 0.99) was found between the glucose concentration of the actual model and the biosensor current response. In conclusion, a ferrocene mediated glucose biosensor incorporated with reverse iontophoresis function was developed.
引用
收藏
页码:1548 / 1555
页数:8
相关论文
共 50 条
  • [1] A Mediated Glucose Biosensor Incorporated with Reverse Iontophoresis Function for Noninvasive Glucose Monitoring
    Congo Tak-Shing Ching
    Tai-Ping Sun
    Su-Hua Huang
    Hsiu-Li Shieh
    Chung-Yuan Chen
    [J]. Annals of Biomedical Engineering, 2010, 38 : 1548 - 1555
  • [2] Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
    Sun, Tai-Ping
    Shieh, Hsiu-Li
    Ching, Congo Tak-Shing
    Yao, Yan-Dong
    Huang, Su-Hua
    Liu, Chia-Ming
    Liu, Wei-Hao
    Chen, Chung-Yuan
    [J]. INTERNATIONAL JOURNAL OF NANOMEDICINE, 2010, 5 : 343 - 349
  • [3] A bifunctional biosensor for subcutaneous glucose monitoring by reverse iontophoresis
    Liu, Jian
    Jiang, Liying
    Liu, Hongmin
    Cai, Xinxia
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 8 - 13
  • [4] Reverse iontophoresis: Noninvasive glucose monitoring in vivo in humans
    Rao, G
    Guy, RH
    Glikfeld, P
    LaCourse, WR
    Leung, L
    Tamada, J
    Potts, RO
    Azimi, N
    [J]. PHARMACEUTICAL RESEARCH, 1995, 12 (12) : 1869 - 1873
  • [5] REVERSE IONTOPHORESIS - DEVELOPMENT OF A NONINVASIVE APPROACH FOR GLUCOSE MONITORING
    RAO, G
    GLIKFELD, P
    GUY, RH
    [J]. PHARMACEUTICAL RESEARCH, 1993, 10 (12) : 1751 - 1755
  • [6] Reverse iontophoresis for noninvasive glucose monitoring: The internal standard concept
    Sieg, A
    Guy, RH
    Delgado-Charro, MBA
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2003, 92 (11) : 2295 - 2302
  • [7] Glucose monitoring by reverse iontophoresis
    Potts, RO
    Tamada, JA
    Tierney, MJ
    [J]. DIABETES-METABOLISM RESEARCH AND REVIEWS, 2002, 18 : S49 - S53
  • [8] Glucose monitoring by reverse iontophoresis
    Tierney, MJ
    [J]. NOVEL APPROACHES IN BIOSENSORS AND RAPID DIAGNOSTIC ASSAYS, 2001, : 285 - 293
  • [9] Glucose monitoring via reverse iontophoresis
    Ackerman, Neil
    Berner, Bret
    Biegajski, Jim
    Chen, Qiang
    Chen, Hilary
    Conn, Tom
    Dehal, Hardip
    Dunn, Tim
    Ewing, Al
    Fermi, Steve
    Ford, Russell
    Jagasia, Priya
    Jayalakshmi, Yalia
    Joshi, Priti
    Kersten, Brian
    Kurnik, Ronald
    Lake, Tim
    Lesho, Matt
    Lin, Jan-Ping
    Liu, David
    Lopatin, Margarita
    Mack, Lexa
    Messenger, Heather
    Morley, Sam
    Oliva, Michelle
    Parris, Norman
    Potts, Russell
    Pudlo, Jeff
    Reidy, Michael
    Soni, Pravin
    Tamada, Janet
    Tierney, Michael
    Uhegbu, Christopher
    Vijayakumar, Prema
    Wei, Charles
    Williams, Steve
    Wilson, Don
    Wu, Christine
    [J]. ACS Symposium Series, 2000, 752 : 273 - 282
  • [10] Noninvasive glucose monitoring by reverse iontophoresis in vivo: Application of the internal standard concept
    Sieg, A
    Guy, RH
    Delgado-Charro, MB
    [J]. CLINICAL CHEMISTRY, 2004, 50 (08) : 1383 - 1390