Homogeneous water nucleation in a laminar flow diffusion chamber

被引:38
|
作者
Manka, Alexandra A. [1 ]
Brus, David [2 ,3 ]
Hyvarinen, Antti-Pekka [2 ]
Lihavainen, Heikki [2 ]
Woelk, Judith [1 ]
Strey, Reinhard [1 ]
机构
[1] Univ Cologne, Inst Phys Chem, D-50939 Cologne, Germany
[2] Finnish Meteorol Inst, FI-00101 Helsinki, Finland
[3] Acad Sci Czech Republic, Inst Chem Proc Fundamentals, Lab Aerosol Chem & Phys, CZ-16502 Prague, Czech Republic
来源
JOURNAL OF CHEMICAL PHYSICS | 2010年 / 132卷 / 24期
关键词
SUPERSATURATED VAPOR; RATES; CONDENSATION; PRESSURE; NUCLEUS; WORK; SIZE;
D O I
10.1063/1.3427537
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Homogeneous nucleation rates of water at temperatures between 240 and 270 K were measured in a laminar flow diffusion chamber at ambient pressure and helium as carrier gas. Being in the range of 10(2)-10(6) cm(-3) s(-1), the experimental results extend the nucleation rate data from literature consistently and fill a pre-existing gap. Using the macroscopic vapor pressure, density, and surface tension for water we calculate the nucleation rates predicted by classic nucleation theory (CNT) and by the empirical correction function of CNT by Wolk and Strey [J. Phys. Chem. B 105, 11683 (2001)]. As in the case of other systems (e.g., alcohols), CNT predicts a stronger temperature dependence than experimentally observed, whereas the agreement with the empirical correction function is good for all data sets. Furthermore, the isothermal nucleation rate curves allow us to determine the experimental critical cluster sizes by use of the nucleation theorem. A comparison with the critical cluster sizes calculated by use of the Gibbs-Thomson equation is remarkably good for small cluster sizes, for bigger ones the Gibbs-Thomson equation overestimates the cluster sizes. (C) 2010 American Institute of Physics. [doi:10.1063/1.3427537]
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A laminar flow diffusion chamber for homogeneous nucleation studies
    Lihavainen, H
    Viisanen, Y
    JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (47): : 11619 - 11629
  • [2] Homogeneous nucleation of n-pentanol in a laminar flow diffusion chamber
    Lihavainen, H
    Viisanen, Y
    Kulmala, M
    JOURNAL OF CHEMICAL PHYSICS, 2001, 114 (22): : 10031 - 10038
  • [3] Homogeneous nucleation of n-pentanol in a Laminar Flow Diffusion Chamber
    Lihavainen, H
    Viisanen, Y
    Kulmala, M
    NUCLEATION AND ATMOSPHERIC AEROSOLS 2000, 2000, 534 : 84 - 87
  • [4] Homogeneous nucleation from a supersaturated sulfur vapor in a laminar flow diffusion chamber
    S. V. Valiulin
    V. V. Karasev
    A. A. Onishchuk
    S. V. Vosel’
    A. Yu. Komarovskikh
    A. M. Baklanov
    P. A. Purtov
    V. V. Boldyrev
    V. M. Fomin
    Doklady Physical Chemistry, 2011, 437 : 31 - 34
  • [5] Homogeneous nucleation from a supersaturated sulfur vapor in a laminar flow diffusion chamber
    Valiulin, S. V.
    Karasev, V. V.
    Onishchuk, A. A.
    Vosel', S. V.
    Komarovskikh, A. Yu
    Baklanov, A. M.
    Purtov, P. A.
    Boldyrev, V. V.
    Fomin, V. M.
    DOKLADY PHYSICAL CHEMISTRY, 2011, 437 : 31 - 34
  • [6] HOMOGENEOUS NUCLEATION IN A LAMINAR FLOW DIFFUSION - INTRODUCTION
    HAMERI, K
    ACTA POLYTECHNICA SCANDINAVICA-APPLIED PHYSICS SERIES, 1995, (200): : 8 - 90
  • [7] Determination of homogeneous nucleation rates from laminar-flow diffusion chamber data
    Wilck, M
    Hameri, K
    Stratmann, F
    Kulmala, M
    JOURNAL OF AEROSOL SCIENCE, 1998, 29 (08) : 899 - 911
  • [8] Homogeneous nucleation of DBP vapour in a laminar flow diffusion chamber: The carrier gas effect
    Hameri, K.
    Kulmala, M.
    Rantanen, E.
    Journal of Aerosol Science, 1995, 26 (Suppl 1):
  • [9] Laminar flow diffusion chamber for nucleation rate measurements
    Lihavainen, H.
    Viisanen, Y.
    Journal of Aerosol Science, 1998, 29 (SUPPL 1)
  • [10] Simulation of the operation of a laminar-flow diffusion chamber to study homogeneous nucleation: Part II
    Brin, A. A.
    Fisenko, S. P.
    TECHNICAL PHYSICS, 2006, 51 (04) : 423 - 430