First Validation of Myocardial Flow Reserve Derived from Dynamic 99mTc-Sestamibi CZT-SPECT Camera Compared with 13N-Ammonia PET A Pilot Study

被引:9
|
作者
Yamamoto, Atsushi [1 ,2 ]
Nagao, Michinobu [2 ]
Ando, Kiyoe [1 ]
Nakao, Risako [1 ]
Matsuo, Yuka [2 ]
Sakai, Akiko [1 ]
Momose, Mitsuru [2 ]
Kaneko, Koichiro [2 ]
Hagiwara, Nobuhisa [1 ]
Sakai, Shuji [2 ]
机构
[1] Tokyo Womens Med Univ, Dept Cardiol, Tokyo, Japan
[2] Tokyo Womens Med Univ, Dept Imaging Diag & Nucl Med, Tokyo, Japan
关键词
Myocardial blood flow; Quantification; PERFUSION RESERVE; BLOOD-FLOW; DISEASE; QUANTIFICATION;
D O I
10.1536/ihj.21-487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
N-13-ammonia positron emission tomography (NH3-PET) can evaluate myocardial blood flow (MBF) at rest, stress, and myocardial flow reserve (MFR) as well as the ratio of MBF at stress to that at rest. MFR is useful in predicting the prognoses of patients with various heart diseases. Cadmium-zinc-telluride single photon emission computed tomography (CZT-SPECT) enables us to acquire dynamic images of radiotracer kinetics and measure original MBF and MFR using Tc-99m-sestamibi. This study aimed to investigate the utility of CZT-SPECT for quantitative assessment of MBF compared to NH3-PET. We validated the correlation of MBF and MFR between CZT-SPECT and NH3-PET. Fourteen patients using one-day rest/stress CZT-SPECT, D-SPECT followed by NH3-PET within 1 month were enrolled and analyzed prospectively. The reproducibility of the MBF and MFR obtained with these two methods was examined using Spearman's correlation coefficient and Bland-Altman plot analysis. The diagnostic value of D-SPECT for abnormal MFR defined using NH3-PET results as MFR < 2.0 was assessed using receiver-operating characteristic (ROC) analysis. The median duration between D-SPECT and NH3-PET was 20 days. Although MBF was overestimated by D-SPECT compared to NH3-PET at high value (mean difference, 0.43 [0.34-0.53]), MBF and MFR were correlated with the two modalities (MBF: r = 0.71, P < 0.0001, MFR: r = 0.60, P < 0.0001). The ROC curve analysis demonstrated a cutoff of 1.6 for detecting abnormal MFR with D-SPECT (sensitivity, 68%; specificity, 91%; AUC, 0.75). MBF and MFR obtained using D-SPECT and NH3-PET had a good correlation, suggesting that the quantitative MFR evaluation by CZT-SPECT may help understand the trend of NH3-PET MFR.
引用
收藏
页码:202 / 209
页数:8
相关论文
共 47 条
  • [1] A preliminary study of dobutamine myocardial flow reserve on 99mTc-Sestamibi CZT-SPECT
    Yan, Ming
    Shang, Hua
    Hao, Luping
    Guo, Xiaorui
    Zheng, Hongming
    Li, Hongmei
    Zhao, Yuchan
    ANNALS OF NUCLEAR MEDICINE, 2023, 37 (06) : 349 - 359
  • [2] A preliminary study of dobutamine myocardial flow reserve on 99mTc-Sestamibi CZT-SPECT
    Ming Yan
    Hua Shang
    Luping Hao
    Xiaorui Guo
    Hongming Zheng
    Hongmei Li
    Yuchan Zhao
    Annals of Nuclear Medicine, 2023, 37 : 349 - 359
  • [3] First Assessment of Myocardial Flow Reserve by Dynamic 99mTc-sestamibi on CZT-SPECT camera in Patients with Congenitally Corrected Transposition of Great Arteries
    Agostini, Denis
    Roth, Nathaniel
    Faudemer, Julie
    Manrique, Alain
    Labombarda, Fabien
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [4] First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study
    Denis Agostini
    Vincent Roule
    Catherine Nganoa
    Nathaniel Roth
    Raphael Baavour
    Jean-Jacques Parienti
    Farzin Beygui
    Alain Manrique
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 1079 - 1090
  • [5] First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study
    Agostini, Denis
    Roule, Vincent
    Nganoa, Catherine
    Roth, Nathaniel
    Baavour, Raphael
    Parienti, Jean-Jacques
    Beygui, Farzin
    Manrique, Alain
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (07) : 1079 - 1090
  • [6] QUANTIFICATION OF ABSOLUTE MYOCARDIAL BLOOD FLOW (MBF) AND MYOCARDIAL FLOW RESERVE (MFR) USING ULTRA-LOW DOSE DYNAMIC CZT-SPECT WITH 99MTC-SESTAMIBI AND DIPYRIDAMOLE: EARLY FINDINGS
    Kwok, C. B. A.
    Saththianathan, M.
    Elison, B.
    Dixson, H.
    Dobson, M.
    Musgrave, S.
    Hasche, E.
    Dunn, M.
    Smillie, C.
    Kilian, J.
    Asrress, K.
    Lee
    INTERNAL MEDICINE JOURNAL, 2021, 51 : 21 - 21
  • [7] Clinical impact of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi CZT SPECT as improving diagnostic accuracy in CAD patients
    Chiu, Chuang-Hsin
    Chen, I-Feng
    Lin, Li-Fan
    Chen, Ing-jou
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [8] TECHNICAL FEASIBILITY OF THE MEASUREMENT OF ABSOLUTE MYOCARDIAL BLOOD FLOW (MBF) AND MYOCARDIAL FLOW RESERVE (MFR) USING NOVEL ULTRA-LOW DOSE DYNAMIC CZT-SPECT TECHNOLOGY WITH 99MTC-SESTAMIBI AND DIPYRIDAMOLE OR DOBUTAMINE
    Dobson, M.
    Behn, J.
    Chiam, Q.
    Dixson, H.
    Bui, C.
    Elison, B.
    Hasche, E.
    Dunn
    Smillie, C.
    Gill, M.
    Lee, K.
    INTERNAL MEDICINE JOURNAL, 2019, 49 : 37 - 37
  • [9] Myocardial perfusion reserve compared with peripheral perfusion reserve: A 13N-ammonia PET study
    Scholtens, Asbjorn M.
    Dierckx, Rudi
    Tio, Rene
    Willems, Antoon T. M.
    Zeebregts, Clark
    Boersma, Hendrikus H.
    Glaudemans, Andor W. J. M.
    Slart, Riemer H. J. A.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [10] The Evaluation of Caffeine Effects in Myocardial Blood Flow, Myocardial Flow Reserve and Hemodynamic Change by 99mTc-sestamibi Dynamic SPECT/CT
    Chan, Hung-Pin
    Hu, Chin
    Peng, Nan-Jing
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62