High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach-Zehnder Interferometers

被引:18
|
作者
Zhao, Na [1 ]
Lin, Qijing [1 ,2 ,3 ,4 ]
Jiang, Zhuangde [1 ]
Yao, Kun [1 ]
Tian, Bian [1 ]
Fang, Xudong [1 ]
Shi, Peng [5 ,6 ]
Zhang, Zhongkai [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710049, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Collaborat Innovat Ctr High End Mfg Equipment, Xian 710054, Shaanxi, Peoples R China
[3] Shanghai Jiao Tong Univ, State Key Lab Mech Syst & Vibrat, Shanghai 200240, Peoples R China
[4] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Peoples R China
[5] Xi An Jiao Tong Univ, Elect Mat Res Lab, Key Lab, Minist Educ, Xian 710049, Shaanxi, Peoples R China
[6] Xi An Jiao Tong Univ, Int Ctr Dielect Res, Sch Elect & Informat Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
high temperature sensing; cascade; Mach-Zehnder interferometer; fiber bitapers; POLYMER OPTICAL-FIBER; THERMAL-CONDUCTIVITY; REFRACTIVE-INDEX; DEPENDENT RAMAN; SENSOR; STRAIN;
D O I
10.3390/s18082688
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A temperature multipoint sensing system based on three cascade Mach-Zehnder interferometers (MZIs) is introduced. The MZIs with different lengths are fabricated based on waist-enlarged fiber bitapers. The fast Fourier transformation is applied to the overlapping transmission spectrum and the corresponding interference spectra can be obtained via the cascaded frequency spectrum based on the inverse Fourier transformation. By analyzing the drift of interference spectra, the temperature response sensitivities of 0.063 nm/degrees C, 0.071 nm/degrees C, and 0.059 nm/degrees C in different furnaces can be detected from room temperature up to 1000 degrees C, and the temperature response at different regions can be measured through the sensitivity matrix equation. These results demonstrate feasibility of multipoint measurement, which also support that the temperature sensing system provides new solution to the MZI cascade problem.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Fiber Mach-Zehnder interferometer based on microcavities for high-temperature sensing with high sensitivity
    Jiang, L.
    Yang, J.
    Wang, S.
    Li, B.
    Wang, M.
    OPTICS LETTERS, 2011, 36 (19) : 3753 - 3755
  • [2] Minimizing temperature sensitivity of silicon Mach-Zehnder interferometers
    Guha, Biswajeet
    Gondarenko, Alexander
    Lipson, Michal
    OPTICS EXPRESS, 2010, 18 (03): : 1879 - 1887
  • [3] Generalized Mach-Zehnder interferometers for sensing applications
    Bernini, R
    Cusano, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 100 (1-2) : 72 - 74
  • [4] Paradoxical behavior in a triple cascade of Mach-Zehnder interferometers
    Parks, A. D.
    Spence, S. E.
    JOURNAL OF PHYSICS A-MATHEMATICAL AND THEORETICAL, 2013, 46 (03)
  • [5] Inline Microfiber Mach-Zehnder Interferometer for High Temperature Sensing
    Jasim, Ali Abdulhadi
    Harun, Sulaiman Wadi
    Arof, Hamzah
    Ahmad, Harith
    IEEE SENSORS JOURNAL, 2013, 13 (02) : 626 - 628
  • [6] High sensitivity temperature sensor using microfiber based Mach-Zehnder interferometer
    Liang, Ruibing
    Sun, Qizhen
    Wo, Jianghai
    Zhang, Jiejun
    Jia, Weihua
    Liu, Deming
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [7] High sensitivity directional torsion sensor based on cascaded multimode and Mach-Zehnder interferometers with spiral structure
    Liu, Yin
    Zhou, Ai
    Yuan, Libo
    ENGINEERING RESEARCH EXPRESS, 2019, 1 (02):
  • [8] HIGH SENSITIVITY AND LARGE MEASUREMENT RANGE REFRACTOMETRIC SENSING BASED ON MACH-ZEHNDER INTERFEROMETER
    Zhang, G.
    Cai, H.
    Gu, Y. D.
    Song, J. F.
    Dong, B.
    Yang, Z. C.
    Jin, Y. F.
    Hao, Y. L.
    Sivalingam, S. P.
    Yap, P. H.
    Kwong, D. L.
    Liu, A. Q.
    2016 IEEE 29TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2016, : 298 - 301
  • [9] High sensitivity fiber temperature sensor based PDMS film on Mach-Zehnder interferometer
    Gong, Jiaqi
    Shen, Changyu
    Xiao, Yike
    Liu, Shuyi
    Zhang, Chong
    Ding, Zeyi
    Deng, Huitong
    Fang, Jiahao
    Lang, Tingting
    Zhao, Chunliu
    Chen, Yi
    OPTICAL FIBER TECHNOLOGY, 2019, 53
  • [10] High temperature high sensitivity Mach-Zehnder interferometer based on waist-enlarged fiber bitapers
    Zhao, Na
    Lin, Qijing
    Jing, Weixuan
    Jiang, Zhuangde
    Wu, Zirong
    Yao, Kun
    Tian, Bian
    Zhang, Zhongkai
    Shi, Peng
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 267 : 491 - 495