A true eddy accumulation system for trace gas fluxes using disjunct eddy sampling method

被引:33
|
作者
Rinne, HJI
Delany, AC
Greenberg, JP
Guenther, AB
机构
[1] Natl Ctr Atmospher Res, Div Atmospher Chem, Boulder, CO 80303 USA
[2] Natl Ctr Atmospher Res, Atmospher Technol Div, Boulder, CO 80303 USA
关键词
D O I
10.1029/2000JD900315
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
A new true eddy accumulation flux measurement system, based on the disjunct sampling approach, has been developed and tested. In disjunct sampling, short, separate samples are taken instead of continuously sampling the air as in traditional relaxed eddy accumulation and eddy covariance systems. This method reduces the number of samples but allows more time to process them. Simulation shows that the fluxes, calculated using disjunct data, are close to those calculated using continuous data. The disjunct true eddy accumulation instrument was successfully deployed to measure monoterpene fluxes at Niwot Ridge, Colorado. The ability of the system to measure the sample flow accurately critical for any eddy accumulation system, was tested using atmospheric CFC-113 as a tracer, with good results. The system was capable of measuring relatively low alpha -pinene fluxes, below 10 ng m(-2) s(-1) at T = 8 degreesC, over a subalpine forest.
引用
收藏
页码:24791 / 24798
页数:8
相关论文
共 50 条
  • [1] The use of disjunct eddy sampling methods for the determination of ecosystem level fluxes of trace gases
    Turnipseed, A. A.
    Pressley, S. N.
    Karl, T.
    Lamb, B.
    Nemitz, E.
    Allwine, E.
    Cooper, W. A.
    Shertz, S.
    Guenther, A. B.
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2009, 9 (03) : 981 - 994
  • [2] Measuring trace gas fluxes on a regional scale using airborne relaxed eddy accumulation
    Fléchard, CR
    Desjardins, RL
    MacPherson, JI
    Zhu, T
    Pattey, E
    [J]. 11TH SYMPOSIUM ON METEOROLOGICAL OBSERVATIONS AND INSTRUMENTATION, 2001, : 151 - 154
  • [3] True eddy accumulation trace gas flux measurements: proof of concept
    Siebicke, Lukas
    Emad, Anas
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (08) : 4393 - 4420
  • [4] A disjunct eddy accumulation system for the measurement of BVOC fluxes: instrument characterizations and field deployment
    Edwards, G. D.
    Martins, D. K.
    Starn, T.
    Pratt, K.
    Shepson, P. B.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (09) : 2115 - 2132
  • [5] Disjunct eddy covariance technique for trace gas flux measurements
    Rinne, HJI
    Guenther, AB
    Warneke, C
    de Gouw, JA
    Luxembourg, SL
    [J]. GEOPHYSICAL RESEARCH LETTERS, 2001, 28 (16) : 3139 - 3142
  • [6] An airborne disjunct eddy covariance system: Sampling strategy and instrument design
    Rinne, J
    Durand, P
    Guenther, A
    [J]. 15TH SYMPOSIUM ON BOUNDARY LAYERS AND TURBULENCE, 2002, : 151 - 154
  • [7] A SIMULATION OF THE EDDY ACCUMULATION METHOD FOR MEASURING POLLUTANT FLUXES
    HICKS, BB
    MCMILLEN, RT
    [J]. JOURNAL OF CLIMATE AND APPLIED METEOROLOGY, 1984, 23 (04): : 637 - 643
  • [8] True eddy accumulation - Part 2:Theory and experiment of the short-time eddy accumulation method
    Emad, Anas
    Siebicke, Lukas
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2023, 16 (01) : 41 - 55
  • [9] Eddy covariance for quantifying trace gas fluxes from soils
    Eugster, W.
    Merbold, L.
    [J]. SOIL, 2015, 1 (01) : 187 - 205
  • [10] Field comparison of disjunct and conventional eddy covariance techniques for trace gas flux measurements
    Rinne, J.
    Douffet, T.
    Prigent, Y.
    Durand, P.
    [J]. ENVIRONMENTAL POLLUTION, 2008, 152 (03) : 630 - 635