Study and application of the fully insulated bench transformer substation of standard building blocks

被引:0
|
作者
Gang, Wang [1 ]
机构
[1] Liaoning Elect Power Co Ltd, Liaoning, Peoples R China
关键词
power distribution; full insulation; bench substation; standardization;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In the distribution network, pole-type transformer is not only the most common device related to power supply safety and environmental beautification, but also in a large amount of number and needs a large number of maintenance. It is difficult to achieve the standardization. In view of the existing problems of the original power transformer substation, such as the poor ability to resist natural disasters, unreliable operation, low intelligence level, non insulation, easy corrosion, technological backwardness, and incoordinated with the environment, the fully insulated transformer substation of standard building blocks is developed by adopting the idea and method of industrial design. The new type bench substation, which is fully insulated and maintenance-free with advanced and reliable materials, is safe, aesthetic, light, simple, corrosion resistant, and environmental protected. It further protects the safety of personnel and equipment, and it is convenient to operate and manage. This paper describes the study contents, technical route, function and application effect of the new type transformer substation respectively.
引用
收藏
页码:935 / 939
页数:5
相关论文
共 5 条
  • [1] Application study of hot dip aluminized steel in transformer substation
    Wang Xuming
    Wang Xianpeng
    Yang Zhanjin
    Yao Boyan
    Han Junke
    Huang Yao
    PROCEEDINGS OF 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION (ICICTA 2015), 2015, : 221 - 224
  • [2] The Application Key Problem and On-site Test Study of Electronic Transformer in Smart Substation
    Yang Huayun
    Jiang Bo
    Jiang Wei
    Aibing
    Yang Huayun
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [3] The Application of BIM in Small and Medium-sized Smart Substation-A Case Study of Prefabricated Building Design
    Tang, Qingsong
    Liu, Zhongyang
    Chen, Wei
    Zhang, Jinmei
    Dong, Xinyuan
    2018 INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT (GBEM 2018), 2018, 186
  • [4] Feasibility study on preparation of fully-waste building blocks using alkali-activated materials to solidify construction and demolition waste residue: Formulation optimization and reaction mechanism
    Wang, Zehui
    Yuan, Quan
    Zhou, Changdong
    Lu, Zhipeng
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 411
  • [5] A fully validated LC-MS/MS method for simultaneous determination of nicotine and its metabolite cotinine in human serum and its application to a pharmacokinetic study after using nicotine transdermal delivery systems with standard heat application in adult smokers
    Abdallah, Inas A.
    Hammell, Dana C.
    Stinchcomb, Audra L.
    Hassan, Hazem E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1020 : 67 - 77