Effect of acupuncture on capillary refill time in healthy adults: A clinical study

被引:3
|
作者
Yeh, Bo-Yan [1 ]
Chao, Yen-Lin [1 ]
Chen, Yu-Sheng [1 ,2 ]
Yu, Huang-Ping [3 ,4 ]
机构
[1] Chang Gung Mem Hosp, Ctr Tradit Chinese Med, Dept Chinese Acupuncture & Traumatol, Taoyuan, Taiwan
[2] Chang Gung Univ, Grad Inst Clin Med Sci, Taoyuan, Taiwan
[3] Chang Gung Mem Hosp, Dept Anesthesiol, 5 Fu Shin St, Taoyuan 333, Taiwan
[4] Chang Gung Univ, Coll Med, Taoyuan, Taiwan
关键词
Acupuncture; Capillary refill time; Root of pulse; KI3; Taixi;
D O I
10.1016/j.mvr.2021.104135
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Pulse examination, which reveals information about bodily qi and blood circulation, is an essential diagnostic tool in traditional Chinese medicine. Capillary refill time (CRT) is a simple test parameter for assessing circulation status. Examining the root of pulse and measuring CRT are extremely similar procedures. The objective of this study was to evaluate the effect of acupuncture on CRT. Methods: Three acupoints were selected to evaluate the effects of CRT. CRT, quantitative CRT, heart rate, core body temperature, and blood pressure were measured before acupuncture and immediately after removal of needles and 30 min after removal of needles. A total of 15 healthy adults representing both sexes were pro-spectively included in the study. The acupoints selected were bilateral Taixi (KI3), Hegu (LI4), and Zusanli (ST36). Each participant received acupuncture three times, interventions were separated by at least 2 days, and acupuncture was performed on only one acupoint at each intervention. Results: CRT decreased significantly after acupuncture on only KI3. Quantitative CRT decreased significantly after acupuncture on KI3 and LI4. Heart rate changed significantly after acupuncture on KI3 and ST36. Conclusion: Acupuncture on KI3 can reduce CRT in health adults.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Capillary refill time in adults
    Lewin, J.
    Maconochie, I.
    EMERGENCY MEDICINE JOURNAL, 2008, 25 (06) : 325 - 326
  • [2] Determinants of Capillary Refill Time in Healthy Neonates
    Singh, Shweta
    Kumar, Hok
    Basu, Sriparna
    Bhatia, Baldev
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (09) : SC1 - SC3
  • [3] Effect of fever on capillary refill time
    Gorelick, MH
    Shaw, KN
    Murphy, KO
    Baker, MD
    PEDIATRIC EMERGENCY CARE, 1997, 13 (05) : 305 - 307
  • [4] Perspectives for capillary refill time in clinical practice for sepsis
    Huang, Weipeng
    Huang, Yiyan
    Ke, Li
    Hu, Chang
    Chen, Pengyu
    Hu, Bo
    INTENSIVE AND CRITICAL CARE NURSING, 2024, 84
  • [5] Capillary Refill Time: Is It Still a Useful Clinical Sign?
    Pickard, Amelia
    Karlen, Walter
    Ansermino, J. Mark
    ANESTHESIA AND ANALGESIA, 2011, 113 (01): : 120 - 123
  • [6] Impact of patient and environmental factors on capillary refill time in adults
    Anderson, Bronwyn
    Kelly, Anne-Maree
    Kerr, Debra
    Clooney, Megan
    Jolley, Damien
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2008, 26 (01): : 62 - 65
  • [7] Measurement of capillary refill time with a handheld prototype device: a comparative validation study in healthy volunteers
    Ruste, M.
    Cazenave, L.
    Tardif, M.
    Saint-Jean, C.
    Fellahi, J. -L.
    Lagreze, M. Jacquet
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (05) : 1271 - 1278
  • [8] Measurement of capillary refill time with a handheld prototype device: a comparative validation study in healthy volunteers
    M. Ruste
    L. Cazenave
    M. Tardif
    C. Saint-Jean
    J.-L. Fellahi
    M. Jacquet Lagrèze
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1271 - 1278
  • [9] EFFECT OF AMBIENT-TEMPERATURE ON CAPILLARY REFILL IN HEALTHY-CHILDREN
    GORELICK, MH
    SHAW, KN
    BAKER, MD
    PEDIATRICS, 1993, 92 (05) : 699 - 702
  • [10] Measurement of Capillary Refill Time (CRT) in Healthy Subjects using a Robotic Hand
    Kerr, Emmett
    Coleman, Sonya
    McGinnity, T. M.
    Shepherd, Andrea
    PROCEEDINGS 2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS (CVPRW), 2018, : 1372 - 1379