The debate on the dependence of apparent contact angles on drop contact area or three-phase contact line: A review

被引:227
|
作者
Erbil, H. Yildirim [1 ]
机构
[1] Gebze Inst Technol, Dept Chem Engn, TR-41400 Gebze, Kocaeli, Turkey
关键词
Contact angles; Wenzel equation; Cassie equation; Contact area; Three-phase contact line; SURFACE-FREE-ENERGY; SCANNING-ELECTRON-MICROSCOPY; CASSIE-BAXTER EQUATION; INTERFACIAL-TENSIONS; SPREADING PRESSURE; POLYMER SURFACES; SOLID-SURFACES; WETTING CHARACTERISTICS; ORGANIC-SUBSTANCES; STATE APPROACH;
D O I
10.1016/j.surfrep.2014.09.001
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A sessile drop is an isolated drop which has been deposited on a solid substrate where the wetted area is limited by the three-phase contact line and characterized by contact angle, contact radius and drop height. Although, wetting has been studied using contact angles of drops on solids for more than 200 years, the question remains unanswered: Is),vetting of a rough and chemically heterogeneous surface controlled by the interactions within the solid/liquid contact area beneath the droplet or only at the three-phase contact line? After the publications of Pease in 1945. Extrand in 1997, 2003 and Gao and McCarthy in 2007 and 2009, it was proposed that advancing, receding contact angles, and contact angle hysteresis of rough and chemically heterogeneous surfaces are determined by interactions of the liquid and the solid at the three-phase contact line alone and the interfacial area within the contact perimeter is irrelevant. As a consequence of this statement, the well-known Wenzel (1934) and Cassie (1945) equations which were derived using the contact area approach are proposed to be invalid and should be abandoned. A hot debate started in the field of surface science after 2007, between the three-phase contact line and interfacial contact area approach defenders. This paper presents a review of the published articles on contact angles and summarizes the views of the both sides. After presenting a brief history of the contact angles and their measurement methods, we discussed the basic contact angle theory and applications of contact angles on the characterization of flat, rough and micropatterned superhydrophobic surfaces. The weak and strong sides of both three-phase contact line and contact area approaches were discussed in detail and some practical conclusions were drawn. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:325 / 365
页数:41
相关论文
共 50 条
  • [1] Dependency of Contact Angles on Three-Phase Contact Line: A Review
    Erbil, H. Yildirim
    COLLOIDS AND INTERFACES, 2021, 5 (01)
  • [2] Effect of three-phase contact line topology on dynamic contact angles on heterogeneous surfaces
    Anantharaju, Neeharika
    Panchagnula, Mahesh V.
    Vedantam, Srikanth
    Neti, Sudhakar
    Tatic-Lucic, Svetlana
    LANGMUIR, 2007, 23 (23) : 11673 - 11676
  • [3] On the interpretation of contact angle for geomaterial wettability: Contact area versus three-phase contact line
    Sadeghinezhad, Emad
    Siddiqui, Mohammed Abdul Qadeer
    Roshan, Hamid
    Regenauer-Lieb, Klaus
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2020, 195
  • [4] THE DEPENDENCE OF CONTACT ANGLES ON DROP SIZE AND LINE TENSION
    GAYDOS, J
    NEUMANN, AW
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1987, 120 (01) : 76 - 86
  • [5] The dependence of the apparent contact angles on gravity
    Sakai, H
    Fujii, T
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 210 (01) : 152 - 156
  • [6] Adsorption at a line of three-phase contact
    Widom, B
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 239 (1-3) : 141 - 144
  • [7] DEPENDENCE OF CONTACT ANGLES ON DROP SIZE AND LINE TENSION.
    Gaydos, J.
    Neumann, A.W.
    1600, (120):
  • [8] EFFECT OF CORRUGATIONS OF THE 3-PHASE LINE ON THE DROP SIZE DEPENDENCE OF CONTACT ANGLES
    LI, D
    LIN, FYH
    NEUMANN, AW
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1991, 142 (01) : 224 - 231
  • [9] Stick-slip of the three-phase line in measurements of dynamic contact angles
    Tavana, H
    Yang, GC
    Yip, CM
    Appelhans, D
    Zschoche, S
    Grundke, K
    Hair, ML
    Neumann, AW
    LANGMUIR, 2006, 22 (02) : 628 - 636
  • [10] Three-phase contact line and line tension of electrolyte solutions in contact with charged substrates
    Ibagon, Ingrid
    Bier, Markus
    Dietrich, S.
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2016, 28 (24)