Falciform Ligament Artery Uptake on 99mTc MAA Planning Scan Before 90Y SIRT Confirmed by Retrospective SPECT/MRI Fusion

被引:2
|
作者
Hokamp, Nils Grosse [1 ,2 ,3 ]
Kobe, Carsten [4 ]
O'Donnell, James K. [5 ]
Gupta, Amit [1 ,2 ]
机构
[1] Case Western Reserve Univ, Dept Radiol, 11000 Euclid Ave, Cleveland, OH 44106 USA
[2] Univ Hosp Cleveland, Med Ctr, Cleveland, OH 44106 USA
[3] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Cologne, Germany
[4] Univ Hosp Cologne, Dept Nucl Med, Cologne, Germany
[5] Univ Hosp Cleveland, Med Ctr, Dept Nucl Med, Cleveland, OH 44106 USA
关键词
selective internal radiation therapy; patent falciform ligament artery; image fusion; INTERNAL RADIATION-THERAPY;
D O I
10.1097/RLU.0000000000002099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Selective internal radiation therapy using 90Y spheres is a treatment option for patients with primary or secondary liver cancer. To avoid complications, screening using 99mTc macroaggregated albumin is performed to identify lung shunting and extrahepatic depositions. For the latter, deposition after the anterior abdominal wall is frequently attributed to a patent falciform artery, although the vessel itself is rarely visible on SPECT/CT scans. We demonstrate that retrospective SPECT/MRI fusion clearly attributes the nuclide accumulation to a patent falciform artery. During selective internal radiation therapy, ice packs were placed on the anterior abdominal wall, resulting in a complication-free treatment. © 2018 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:522 / 523
页数:2
相关论文
共 22 条
  • [1] Systematic Evaluation of Tumoral 99mTc-MAA Uptake Using SPECT and SPECT/CT in 502 Patients Before 90Y Radioembolization
    Ilhan, Harun
    Goritschan, Anna
    Paprottka, Phillip
    Jakobs, Tobias F.
    Fendler, Wolfgang P.
    Bartenstein, Peter
    Hacker, Marcus
    Haug, Alexander R.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 333 - 338
  • [2] Impact of Lung Truncation in 99mTc-MAA SPECT/CT for 90Y Radioembolization Treatment Planning
    Thomas, Allan
    Malone, Chris
    Karageorgiou, John
    Giardina, Dan
    Laforest, Richard
    Mikell, Justin
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [3] Combining 99mTc-MAA SPECT/CT and 18-FDG PET/CT for planning liver 90Y radioembolization (SIRT)
    Chalaye, J.
    Bernardini, M.
    Smadja, C.
    Pellerin, O.
    Dubreuil, O.
    Pelage, J.
    Sapoval, M.
    Rougier, P.
    Taieb, J.
    Darcourt, J.
    Faraggi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S435 - S435
  • [4] Is 99mTc-MAA scan essential in 90Y radioembolization planning?: an analysis of 532 patients.
    Rodriguez, Lidia Sancho
    Rodraguez-Fraile, Macarena
    Prieto, Elena
    Mora, Veraonica
    Martinez-Urbistondo, Diego
    IAarrairaegui, Mercedes
    Marta-Climent, Josep
    Arbizu, Javier
    Bilbao, Josa Ignacio
    Sangro, Bruno
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [5] 90Y SPECT/CT quantitative study and comparison of uptake with pretreatment 99 mTc-MAA SPECT/CT in radiomicrosphere therapy
    Debebe, Senait Aknaw
    Adjouadi, Malek
    Gulec, Seza A.
    Franquiz, Juan
    McGoron, Anthony J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (02): : 30 - 42
  • [6] Addressing lung truncation in 99mTc-MAA SPECT/CT for 90Y microsphere radioembolization treatment planning
    Thomas, M. Allan
    Laforest, Richard
    Karageorgiou, John
    Giardina, Dan
    Fraum, Tyler J.
    Malone, Chris D.
    Mikell, Justin K.
    EJNMMI PHYSICS, 2024, 11 (01):
  • [7] The impact of missing attenuation or scatter correction on 99mTc MAA SPECT based dosimetry for 90Y microsphere liver radioembolization
    Botta, F.
    De Nile, M.
    Vitali, S.
    Mira, M.
    Lorenzon, L.
    Ferrari, M.
    Pacilio, M.
    Chiesa, C.
    Cremonesi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S407 - S407
  • [8] Quantitative Comparison of Yttrium-90 (90Y)-Microspheres and Technetium-99m (99mTc)-Macroaggregated Albumin SPECT Images for Planning 90Y Therapy of Liver Cancer
    Knesaurek, Karin
    Machac, Josef
    Muzinic, Michael
    DaCosta, Maria
    Zhang, Zhuangyu
    Heiba, Sherif
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (03) : 253 - 261
  • [9] Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?
    Burgmans, M. C.
    Too, C. W.
    Kao, Y. H.
    Goh, A. S. W.
    Chow, P. K. H.
    Tan, B. S.
    Tay, K. H.
    Lo, R. H. G.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 3979 - 3984
  • [10] Deep learning-guidedjoint attenuation and scatter correction in 99mTc-MAA SPECT images: towards quantitative analysis in 90Y SIRT
    Mansouri, Zahra
    Salimi, Yazdan
    Akhavanallaf, Azadeh
    Sanaat, Amirhossein
    Wolf, Nicola Bianchetto
    Shiri, Isaac
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64