Resection plane-dependent error in computed tomography volumetry of the right hepatic lobe in living liver donors

被引:13
|
作者
Kwon, Heon-Ju [1 ]
Kim, Kyoung Won [2 ]
Kim, Bohyun [3 ]
Kim, So Yeon [2 ]
Lee, Chul Seung [2 ]
Lee, Jeongjin [4 ]
Song, Gi Won [5 ]
Lee, Sung Gyu [5 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Radiol, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[3] Ajou Univ Hosp, Dept Radiol, Suwon, South Korea
[4] Soongsil Univ, Sch Comp Sci & Engn, Seoul, South Korea
[5] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Surg,Div Hepatobiliary & Liver Transplantat, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Liver transplantation; Living Donors; Volumetric computed tomography; Organ volume; Liver; GRAFT VOLUME; TRANSPLANTATION; CT; WEIGHT; SEGMENTATION; ACCURACY; LESSONS; SAFETY;
D O I
10.3350/cmh.2017.0023
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: Computed tomography (CT) hepatic volumetry is currently accepted as the most reliable method for preoperative estimation of graft weight in living donor liver transplantation (LDLT). However, several factors can cause inaccuracies in CT volumetry compared to real graft weight. The purpose of this study was to determine the frequency and degree of resection plane-dependent error in CT volumetry of the right hepatic lobe in LDLT. Methods: Forty-six living liver donors underwent CT before donor surgery and on postoperative day 7. Prospective CT volumetry (V-P) was measured via the assumptive hepatectomy plane. Retrospective liver volume (V-R) was measured using the actual plane by comparing preoperative and postoperative CT. Compared with intraoperatively measured weight (W), errors in percentage (%) V-P and V-R were evaluated. Plane-dependent error in V-P was defined as the absolute difference between V-P and V-R. % plane-dependent error was defined as follows: |V-P-V-R|/W center dot 100. Results: Mean V-P, V-R, and W were 761.9 mL, 755.0 mL, and 696.9 g. Mean and % errors in V-P were 73.3 mL and 10.7%. Mean error and % error in V-R were 64.4 mL and 9.3%. Mean plane-dependent error in V-P was 32.4 mL. Mean % planedependent error was 4.7%. Plane-dependent error in V-P exceeded 10% of W in approximately 10% of the subjects in our study. Conclusions: There was approximately 5% plane-dependent error in liver V-P on CT volumetry. Plane-dependent error in V-P exceeded 10% of W in approximately 10% of LDLT donors in our study. This error should be considered, especially when CT volumetry is performed by a less experienced operator who is not well acquainted with the donor hepatectomy plane.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 50 条
  • [1] Resection Plane-Dependent Error of CT Volumetry for Right Hepatic Lobe in Live Liver Donors
    Kwon, Heon-Ju
    Kim, Kyoung Won
    Kim, Bohyun
    Kim, So Yeon
    Lee, Jeongjin
    Song, Gi Won
    Lee, Sung Gyu
    TRANSPLANTATION, 2016, 100 : S259 - S260
  • [2] Hepatic Computed Tomography Volumetry for Noninvasive Detection of Hepatic Steatosis and Steatohepatitis in Living Liver Donors
    Eshraghian, Ahad
    Rasekhi, Alireza
    Nikeghbalian, Saman
    Muhammad, Shah
    Kazemi, Kourosh
    Jalaeian, Hamed
    Shamsaeefar, Alireza
    Geramizadeh, Bita
    Malek-Hosseini, Sayed Ali
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2022, 20 (04) : 388 - 394
  • [3] Manual and semi-automated computed tomography volumetry significantly overestimates the right liver lobe graft weight: a single-center study with adult living liver donors
    Celik, Hakki
    Odaman, Hueseyin
    Altay, Canan
    Unek, Tarkan
    Ozbilgin, Muecahit
    Egeli, Tufan
    Agalar, Cihan
    Astarcioglu, Ibrahim Kemal
    Barlik, Funda
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (01): : 3 - 8
  • [4] Impact of the Inferior Right Hepatic Veins on Right Liver Lobe Regeneration in Living-Donor Liver Transplant: 3-Dimensional Computed Tomography Scan Analyses in Donors and Recipients
    Pravisani, Riccardo
    Soyama, Akihiko
    Takatsuki, Mitsuhisa
    Hidaka, Masaaki
    Adachi, Tomohiko
    Ono, Shinichiro
    Hara, Takanobu
    Hamada, Takashi
    Eguchi, Susumu
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2019, 17 (06) : 768 - 774
  • [5] Analysis of complications in hepatic right lobe living donors
    Azzam, Ayman
    Uryuhara, Kinji
    Taka, Ito
    Takada, Yasutsugu
    Egawa, Hiroto
    Tanaka, Koichi
    ANNALS OF SAUDI MEDICINE, 2010, 30 (01) : 18 - 24
  • [6] Estimation of Right Lobe Graft Weight from Computed Tomographic Volumetry for Living Donor Liver Transplantation
    Yu, H. C.
    Hwang, H. P.
    Yang, J. D.
    Yang, X.
    You, H. C.
    Chu, C. W.
    Yang, K. H.
    TRANSPLANTATION, 2017, 101 (05) : 222 - 222
  • [7] Variations of hepatic veins: Helical computerized tomography experience in 100 consecutive living liver donors with emphasis on right lobe
    Orguc, S
    Tercan, M
    Bozoklar, A
    Akyildiz, M
    Gurgan, U
    Celebi, A
    Nart, D
    Karasu, Z
    Icoz, G
    Zeytunlu, M
    Yuzer, Y
    Tokat, Y
    Kilic, M
    TRANSPLANTATION PROCEEDINGS, 2004, 36 (09) : 2727 - 2732
  • [8] Severe psychiatric problems in right hepatic lobe donors for living donor liver transplantation
    Trotter, James F.
    Hill-Callahan, Margaret M.
    Gillespie, Brenda W.
    Nielsen, Carrie A.
    Saab, Sammy
    Shrestha, Roshan
    Talamantes, Michael M.
    Weinrieb, Robert M.
    TRANSPLANTATION, 2007, 83 (11) : 1506 - 1508
  • [9] Comparison of pulmonary function test and computed tomography volumetry in living lung donors
    Chen, Fengshi
    Kubo, Takeshi
    Shoji, Tsuyoshi
    Fujinaga, Takuji
    Bando, Toru
    Date, Hiroshi
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (05): : 572 - 575
  • [10] ANALYSIS OF COMPLICATIONS IN HEPATIC RIGHT LOBE LIVING DONORS.
    Azzam, Ayman Zaki
    Uryuhara, Kinji
    Ito, T.
    Takada, Y.
    Egawa, H.
    Tanaka, Kiochi
    LIVER TRANSPLANTATION, 2009, 15 (07) : S247 - S247