Fabrication and calibration of three temperature probes for monitoring the effects of thermal cancer ablation

被引:0
|
作者
Caponero, M. A. [1 ]
Polimadei, A. [1 ]
Ariano, M. [2 ]
Schena, E. [2 ]
Massaroni, C. [2 ]
Silvestri, S. [2 ]
Saccomandi, P. [3 ]
机构
[1] ENEA, Res Ctr Frascati, Photon Micro & Nanostruct Lab, Frascati, Italy
[2] Univ Campus Biomed Roma, Lab Measurement & Biomed Instrumentat, Rome, Italy
[3] Inst Image Guided Surg, IHU, Strasbourg, France
关键词
Temperature measurement; fiber Bragg grating sensors; tumor ablation; thermal treatment; thermal sensitivity; LASER-INDUCED THERMOTHERAPY; CT-BASED THERMOMETRY; EX-VIVO; THEORETICAL-ANALYSIS; SENSORS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Minimally invasive thermal techniques are gaining acceptance in cancer removal. These approaches aim at destroying the tumour while minimizing the damage of surrounding healthy structures. Several solutions have already proved their effectiveness in improving treatment outcomes and in minimizing adverse events. However, it is still challenging to selectively remove the cancer. To help tackle this challenge, several groups of research are focusing on the use of thermometry for monitoring the effects on biological tissue of hyperthermal treatments, since the irreversible damage of tissue depends on temperature and time of application. Given the rising complexity of treatment settings, a temperature feedback may be useful to improve the clinical outcome by minimizing the thermal damage of surrounding healthy tissue. Fiber Bragg grating (FBG) sensors are used in this scenario thanks to several advantages, such as the small size, Magnetic Resonance (MR) compatibility and the possibility to perform spatially distributed measurements; moreover, with the use of specific coating their thermal sensitivity may be increased. However, they are fragile and their insertion within the organ can be challenging and time consuming. In this paper we describe the fabrication of three thermal probes embedding FBG sensors. Each probe consists of a MR-compatible needle which embeds a FBG sensor glued with epoxy adhesive. The three probes showed a sensitivity of about 24 pm/degrees C, which his higher than the one showed by nonencapsulated FBG (about 10 pm/degrees C). Moreover, the output of the three probes showed a negligible output drift and a negligible sensitivity drift after 4 thermal cycles in a wide range of temperature (i.e., from environmental temperature up to about 80 degrees C). The investigated solution shows some advantages considering the specific field of application: it allows an easy insertion within the organ being embedded within a needle; the probes' sensitivity is better than non-encapsulated FBGs; it can be used also during MR-guided procedures since both the needle and the FBG are MR-compatible. Future testing will assess the feasibility for temperature monitoring during thermal ablation treatment of the probes in ex vivo and in vivo animal model.
引用
收藏
页码:420 / 424
页数:5
相关论文
共 50 条
  • [1] Micromachined temperature calibration tool for contact Scanning Thermal Microscope probes
    Bontempi, A.
    Nguyen, T. P.
    Lemaire, E.
    Thiery, L.
    Teyssieux, D.
    Euphrasie, S.
    Briand, D.
    Vairac, P.
    2015 21ST INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS (THERMINIC), 2015,
  • [2] Design, fabrication, and calibration of a micromachined thermocouple for biological applications in temperature monitoring
    Srivannavit, Onnop
    Joshi, Rakesh
    Zhu, Weibin
    Gong, Bin
    Turnbull, Irene C.
    Patel, Vishwendra
    Sealfon, Stuart C.
    Borca-Tasciuc, Theodorian
    Blitzer, Robert D.
    Gaitas, Angelo
    BIOSENSORS & BIOELECTRONICS, 2025, 267
  • [3] Calibration Tools for Scanning Thermal Microscopy Probes Used in Temperature Measurement Mode
    Nguyen, T. P.
    Thiery, L.
    Euphrasie, S.
    Lemaire, E.
    Khan, S.
    Briand, D.
    Aigouy, L.
    Gomes, S.
    Vairac, P.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2019, 141 (07):
  • [4] Soil material, temperature, and salinity effects on calibration of multisensor capacitance probes
    Baumhardt, RL
    Lascano, RJ
    Evett, SR
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2000, 64 (06) : 1940 - 1946
  • [5] Effects of Thermal Drifts on the Calibration of Capacitive Displacement Probes at the Nanometer Level of Accuracy
    Bouderbala, Kamelia
    Nouira, Hichem
    Girault, Manuel
    Videcoq, Etienne
    Salgado, Jose Antonio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (11) : 3062 - 3074
  • [6] Microwave thermal ablation of a porcine liver with temperature monitoring in open MR
    Okada, A
    Kuroda, K
    Abe, H
    Keserci, B
    Khankan, AM
    Kumamoto, E
    RADIOLOGY, 2002, 225 : 164 - 164
  • [7] EFFECTS OF EMISSIVITY ON TEMPERATURE DATA IN THERMAL MONITORING
    VAVILOV, VP
    GORBUNOV, VI
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1977, 13 (01): : 50 - 55
  • [8] Electrical and Thermal Effects of Esophageal Temperature Probes on Radiofrequency Catheter Ablation of Atrial Fibrillation: Results from a Computational Modeling Study
    Perez, Juan J.
    D'Avila, Andre
    Aryana, Arash
    Berjano, Enrique
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (05) : 556 - 564
  • [9] Electrical and Thermal Effects of Esophageal Temperature Probes on Radiofrequency Catheter Ablation of Atrial Fibrillation: Results from a Computational Modeling Study
    Perez, J. J.
    d'Avila, A.
    Aryana, A.
    Berjano, E.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 863 - 866
  • [10] Fabrication of Silk Fibroin Film With Properties of Thermal Insulation and Temperature Monitoring
    Zhao, Liang
    Wang, Hao
    Luo, Jie
    Cai, Cheng
    Song, Guo L.
    Tang, Guo Y.
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2016, 54 (18) : 1846 - 1852