A system has been designed to provide traceable calibration of ultraviolet (UV) radiometers used with broadband and extended sources of the type commonly employed in clinical phototherapy and photobiology research. Traceability requires both an unbroken chain of steps to the primary standard held by a national laboratory and the checking of those steps by an accreditation body. The system described is traceable to the cryogenic radiometer at the National Physical laboratory (NPL) and is accredited by the United Kingdom Accreditation Service (UKAS). The best expanded uncertainty that can be obtained for single wavelength irradiance responsivities is 7% (at 95% confidence) in the wavelength range 250-400 nm. The measured meter characteristics are used along with tabulated data on the spectral properties of the source and, if required, the action spectrum of the radiation to calculate an appropriate calibration for the meter.
引用
收藏
页码:153 / 156
页数:4
相关论文
共 50 条
  • [1] UKAS accredited calibrations
    不详
    CHEMISTRY & INDUSTRY, 2006, (16) : 34 - 34
  • [2] Uncertainty in calibration of ultraviolet radiometers
    Lloyd, JJ
    BRITISH JOURNAL OF DERMATOLOGY, 2003, 148 (04) : 865 - 866
  • [3] Characterization and calibration of broadband ultraviolet radiometers
    Xu, G
    Huang, X
    METROLOGIA, 2000, 37 (03) : 235 - 242
  • [4] New search for calibration method of broad-band ultraviolet radiometers
    Wang, Bingzhong
    Ding, Lei
    Yang, Yun
    Wang, Dong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2009, 30 (07): : 855 - 860
  • [5] UKAS accredited for indirect lightning and HIRF tests
    不详
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2007, 79 (01): : 114 - 114
  • [6] An improved outdoor calibration procedure for broadband ultraviolet radiometers
    Cancilllo, ML
    Serrano, A
    Antón, M
    García, JA
    Vilaplana, JM
    de la Morena, B
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2005, 81 (04) : 860 - 865
  • [7] Kennel Club accredited by UKAS to certify dog breeders
    不详
    VETERINARY RECORD, 2013, 172 (16) : 409 - 409
  • [8] A new calibration technique for interferometric radiometers
    Corbella, I
    Torres, F
    Camps, A
    Bará, J
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES II, 1998, 3498 : 359 - 366
  • [9] Calibration of the broadband radiometers of the Finnish solar ultraviolet monitoring network
    Leszczynski, K
    Jokela, K
    Visuri, R
    Ylianttila, L
    METROLOGIA, 1996, 32 (06) : 701 - 704
  • [10] UKAS accredits CRM calibration laboratory
    Lenk, R
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (04) : IV - +