Energy Consumption Analysis and Energy-saving Reconstruction of New Wall of Prefabricated Single Building in Heating Season

被引:0
|
作者
Jin, Qiang [1 ]
Huang, Darong [1 ,2 ]
Deng, Zhenping [2 ]
Su, Yue [1 ]
Wu, Huadong [3 ]
Xia, Xianyu [4 ]
机构
[1] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[2] Chongqing Jiaotong Univ, Coll Informat Sci & Engn, Chongqing 400074, Peoples R China
[3] Chongqing ZhikuZhizao Integrated Housing Co Ltd, Chongqing 400036, Peoples R China
[4] Chonqing Real Estate Coll, Chongqing 401331, Peoples R China
基金
中国国家自然科学基金;
关键词
Prefabricated single building; energy consumption analysis; thermal load; energy-saving reconstruction;
D O I
10.23919/chicc.2019.8865309
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Directing against the energy consumption analysis and energy saving reconstruction of new wall of prefabricated single building in heating season, proposing a new type of assembled building structure system, with emphasis on new wall and concrete wall, taking the engineering construction of prefabricated single building in Chongqing as an example, the difference of energy consumption between the new wall of prefabricated single building and concrete wall have been compared and analyzed based on the simulation software DeST developed by Tsinghua University. The experiment result shows that the annual energy consumption of new wall in prefabricated single building model is lower than that of the concrete model compared with ordinary aluminum alloy single glass windows and energy-saving Windows. What's more, the energy-saving rate of new wall can reach 29%, which equals 75001cwh of power or 923kg of standard coal. The average room temperature of prefabricated single building can reach 13.51 degrees C compared with concrete model which average room temperature is 11.96 degrees C. The difference of dynamic temperature between the two models can reach 2 degrees C-4 degrees C. Furthermore, the thermal load of the new wall model of the prefabricated single building is about 33.18 W/m the concrete model is about 63.1 W/m. After the energy-saving reconstruction, the energy consumption of ordinary window system is 1200kwh/m, the inert gas-plated low-e membrane hollow window system of that is 900kwh/m and the saving energy rate is about 25%.
引用
下载
收藏
页码:6514 / 6519
页数:6
相关论文
共 50 条
  • [1] Analysis and Research on Energy-Saving Reconstruction of Building Heating System
    Liu, Yongqiang
    Huang, Zhanfang
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [2] Simulation and analysis of energy consumption of the energy-saving building in Shanghai
    Sun, Jianmei
    Chen, Di
    Hu, Jiadong
    PROCEEDINGS OF THE 2017 3RD INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS (IFEESM 2017), 2017, 120 : 407 - 410
  • [3] Application of Energy Consumption Simulation in Envelope Energy-Saving Reconstruction of Existing Building
    Cui, Yanqiu
    Wei, Ruihan
    Luo, Cailing
    Miao, Jikui
    ARCHITECTURE AND BUILDING MATERIALS, PTS 1 AND 2, 2011, 99-100 : 644 - +
  • [4] HEAT CONSUMPTION ANALYSIS AND ENERGY-SAVING RENOVATION OF BUILDING HEATING IN HIGH SUNSHINE HEATING AREA
    Zhan, Meiqiu
    Zhang, Wanxi
    THERMAL SCIENCE, 2020, 24 (05): : 3205 - 3212
  • [5] Environmental thermal performance of prefabricated buildings based on building wall energy-saving technology
    Zou D.
    Sun C.
    International Journal of Sustainable Development and Planning, 2020, 15 (06): : 965 - 969
  • [6] Energy-saving control method of electric heating film temperature for urban zero energy consumption building heating
    Jin, Zhe-Liang
    Davis, Martinez
    INTERNATIONAL JOURNAL OF GLOBAL ENERGY ISSUES, 2020, 42 (5-6) : 323 - 338
  • [7] Research on Energy Consumption for Heating from Implementing "50% Energy-saving Standard" and "65% Energy-saving Standard"
    Bai Li
    Chen Zhao
    Chu Jiarui
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 1246 - +
  • [8] Energy-Saving Design and Energy Consumption Analysis of a New Vacuum Refrigerator
    Zhang, Nuonan
    Guo, Yun
    Yuan, Weijian
    Lin, Yaolin
    BUILDINGS, 2022, 12 (02)
  • [9] The unit fuel consumption analysis and energy saving of the building heating
    Jiang, Yuanyuan
    Zhou, Shaoxiang
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 1324 - 1327
  • [10] Application Analysis of the Wall Insulation Construction Technology in Energy-saving of Building