Immediate versus conventions loading of variable-thread tapered implants supporting three- to four-unit fixed partial dentures in he posterior maxilla: 3-year results of a split-mouth randomised controlled trial

被引:0
|
作者
Daher, Fadi I. [1 ]
Abi-Aad, Habib L. [1 ]
Dimassi, Hani I. [2 ]
Cordioli, Giampiero
Majzoub, Zeina A. K. [1 ]
机构
[1] Lebanese Univ, Fac Dent Med, Dept Periodont, Hadath, Lebanon
[2] Lebanese Amer Univ, Sch Pharm, Dept Pharmaceut Sci, Byblos, Lebanon
关键词
immediate loading; maxilla; randomised controlled clinical trial; smoking; variable thread tapered implant; PARTIALLY EDENTULOUS PATIENTS; DENTAL IMPLANTS; FOLLOW-UP; FULL-ARCH; CLINICAL-TRIAL; LOADED IMPLANTS; SINGLE IMPLANTS; RISK-FACTORS; NON-OCCLUSAL; RETROSPECTIVE COHORT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the 3-year outcomes of immediately loaded and one-stage conventionally loaded variable-thread tapered implants in the posterior maxilla. Materials and methods: This study was designed as a split-mouth randomised controlled trial. Twenty-six patients attending the postgraduate Periodontics Department at the Lebanese University, and missing teeth bilaterally in the posterior maxilla were randomised. All patients received three to four implants in each of the posterior sextants. The implants on one side were immediately loaded with a provisional resin fixed partial denture on definitive multi-unit abutments regardless of their primary stability. The implants in the contralateral side received definitive multi-unit abutments according to the one-stage unloaded protocol. Three to 3.5 months following implant placement, the implants were restored with metal-ceramic fixed prostheses. Outcome measures were implant and prosthesis failure rates, complications, and peri-implant bone level changes up to 3 years following delivery of the definitive prosthesis. The clinical outcomes and radiographic measurements were performed by a single outcome assessor blinded to the type of interventions. Results: Two patients dropped out prior to the delivery of definitive prostheses. The results were analysed using a per-protocol analysis and included 24 patients. Four implants supporting a fourunit immediately loaded prosthesis failed in one patient, 3 months following definitive prosthesis. In the same patient, the three contralateral conventionally loaded implants failed 14 months after definitive prosthesis. There were no significant differences in the proportions of implant and prosthesis failures at 3 years (difference = 0%; 95% CI 0.0% to 14.2%; P = 0.999). Periimplantitis was diagnosed at two adjacent conventionally loaded implants in one patient at the 3-year examination. In the immediately loaded group, four early minor prosthetic complications occurred during the provisionalisation phase. Following delivery of the definitive prostheses, one minor ceramic fracture was observed in each of the implant groups. The difference in the rate of complications between the two interventions was not statistically significant at 3 years (difference = 13%; 95% CI 3.4% to 27.7%; P= 0.453). The 3-year pen-implant marginal bone level changes were evaluated in 23 patients (77 immediately loaded and 76 conventionally loaded implants). On average, patients lost 0.79 (0.62) mm at the immediately loaded and 0.91 (0.82) mm at the conventionally loaded implants, the difference being statistically not significant (difference = 0.12 mm; 95% CI -0.31 to 0.55 mm; P = 0.590). The 3-year marginal bone level changes were not significantly different between smokers (n = 12) and non-smokers (n = 11) (difference = 0.19 mm; 95% CI -0.24 to 0.62 mm; P = 0.382). Conclusions: Immediate loading of three- to four-unit fixed partial prostheses supported by variable-thread implants in the posterior maxilla can achieve similar 3-year results to one-stage conventionally loaded implants.
引用
收藏
页码:449 / 466
页数:18
相关论文
共 7 条
  • [1] Immediate vs conventional loading of variable-thread tapered implants supporting three- to four-unit fixed partial dentures in the posterior maxilla: 1-year interim results of a split-mouth randomised controlled trial
    Abi-Aad, Habib
    Daher, Fadi
    Dimassi, Hani
    Cordioli, Giampiero
    Majzoub, Zeina
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2018, 11 (03) : 337 - 350
  • [2] Immediate loading of dental implants supporting fixed partial dentures in the posterior mandible: A randomized controlled split-mouth study - Machined versus titanium oxide implant surface
    Schincaglia, Gian Pietro
    Marzola, Riccardo
    Scapoli, Chiara
    Scotti, Roberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (01) : 35 - 46
  • [3] Comparison of variable-thread tapered implant designs to a standard tapered implant design after immediate loading. A 3-year multicentre randomised controlled trial
    Arnhart, Christoph
    Kielbassa, Andrej M.
    Martinez-de Fuentes, Rafael
    Goldstein, Moshe
    Jackowski, Jochen
    Lorenzoni, Martin
    Maiorana, Carlo
    Mericske-Stern, Regina
    Pozzi, Alessandro
    Rompen, Eric
    Sanz, Mariano
    Strub, Joerg R.
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2012, 5 (02) : 123 - 136
  • [4] Three-year post-loading results of a randomised, controlled, split-mouth trial comparing implants with different prosthetic interfaces and design in partially posterior edentulous mandibles
    Pozzi, Alessandro
    Tallarico, Marco
    Moy, Peter K.
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (01) : 47 - 61
  • [5] Immediate loading of three (fixed-on-3) vs four (fixed-on-4) implants supporting cross-arch fixed prostheses: 1-year results from a multicentre randomised controlled trial
    Cannizzaro, Gioacchino
    Cavallari, Marco
    Lazzarini, Matteo
    D'ambrosio, Giuseppe Purello
    Scialpi, Gianluigi
    Audino, Salvatore
    Velasco-Ortega, Eugenio
    Ippolito, Daniela Rita
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2018, 11 (03) : 323 - 333
  • [6] Immediate loading of two (fixed-on-2) versus three (fixed-on-3) implants placed flapless supporting cross-arch fixed prostheses: One-year results from a randomised controlled trial
    Cannizzaro, Gioacchino
    Loi, Ignazio
    Viola, Paolo
    Ferri, Vittorio
    Leone, Michele
    Trullenque-Eriksson, Anna
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2016, 9 (02) : 143 - 153
  • [7] Immediate loading of two (fixed-on-2) vs four (fixed-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: 3-year results from a pilot randomised controlled trial
    Cannizzaro, Gioacchino
    Felice, Pietro
    Gherlone, Enrico
    Barausse, Carlo
    Ferri, Vittorio
    Leone, Michele
    Trullenque-Eriksson, Anna
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (02) : 133 - 145