Determination of plasma and brain levels of isotretinoin in mice following single oral dose by high-performance liquid chromatography

被引:7
|
作者
Yang, YS
Faustino, PJ
Pine, PS
Davis, H
Grunberg, N
Phillips, J
Lyon, RC
Yu, LX
Ciavarella, AB
Del Grosso, AV
Hanig, JP
机构
[1] US FDA, Ctr Drug Evaluat & Res, Div Prod Qual Res, Silver Spring, MD 20993 USA
[2] US FDA, Ctr Drug Evaluat & Res, Div Appl Pharmacol, Silver Spring, MD 20993 USA
[3] Uniformed Serv Univ Hlth Sci, Dept Med & Clin Psychol, Bethesda, MD 20814 USA
[4] US FDA, Ctr Drug Evaluat & Res, Off Gener Drugs, Rockville, MD 20855 USA
[5] US FDA, Ctr Biol Evaluat & Res, Analyt Chem Lab, Rockville, MD 20852 USA
关键词
accutane; isotretinoin; HPLC; pharmacokinetics; mice;
D O I
10.1016/j.jpba.2004.10.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An isocratic reversed-phase high-performance liquid chromatographic method was established and validated according to FDA's Guidance for Industry, "Bioanalytical Method Validation", for the determination of isotretinoin in plasma and brain tissue from mice following single and multiple oral doses of Accutane(R). Plasma sample preparation included deproteination with acetonitrile-perchloric acid followed by centrifugation. Brain tissue was homogenized and extracted with acetonitrile-perchlorie acid followed by centrifugation. The supernatants were analyzed by high-performance liquid chromatography (HPLC). Benz[alpha]anthrancene-7,12-dione was used as the internal standard. Chromatographic separation was achieved on a C-18 column using an acetonitrile-aqueous 0.5% acetic acid (85:15, v/v) elution. The average 9 extraction efficiency was >95% for plasma and >82% for brain. The lower limit of quantification was 30 ng/mL for plasma and was 30 ng/0.1 g for brain tissue, respectively. The linear range for plasma was 30-600 ng/mL, and 15-300 ng/0.1 g for brain. Maximum concentrations of isotretinoin in both plasma and brain were observed at I h after single oral dosing (25 mg/kg). The maximum concentrations in plasma and brain were 2.36 mug/mL and 0.34 mug/g, respectively. The mean area under curve (AUC) in plasma was 6.13 mug h/mL. The mean eliminate half-life in plasma was estimated as 46 min. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 50 条
  • [1] Determination of plasma levels of bupivacaine by high-performance liquid chromatography
    Yu, Hsiu-Ying
    Li, Shyh-Dar
    Juang, Sin-Yi
    Chinese Pharmaceutical Journal, 1999, 51 (02): : 163 - 170
  • [2] DETERMINATION OF ATENOLOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH APPLICATION TO SINGLE-DOSE PHARMACOKINETICS
    MILLER, LG
    GREENBLATT, DJ
    JOURNAL OF CHROMATOGRAPHY, 1986, 381 (01): : 201 - 204
  • [3] DETERMINATION OF PLASMA-LEVELS OF BUPIVACAINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    RUZAFA, A
    PASTOR, MC
    AGUILAR, JL
    GALIMANY, R
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (15): : 2937 - 2949
  • [4] DETERMINATION OF RANITIDINE IN RAT PLASMA AND BRAIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GUISO, G
    FRACASSO, C
    CACCIA, S
    ABBIATI, A
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 413 : 363 - 369
  • [5] Determination of gabapentin in plasma by high-performance liquid chromatography
    Forrest, G
    Sills, GJ
    Leach, JP
    Brodie, MJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 681 (02): : 421 - 425
  • [6] Determination of hypericin in plasma by high-performance liquid chromatography
    Chi, JD
    Franklin, M
    JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (01): : 195 - 198
  • [7] Determination of aloesin in plasma by high-performance liquid chromatography
    Kim, MJ
    Shin, WG
    RESEARCH COMMUNICATIONS IN MOLECULAR PATHOLOGY AND PHARMACOLOGY, 1998, 99 (01) : 125 - 128
  • [9] Determination of paraquat in plasma by high-performance liquid chromatography
    Hsiu-Ying, Yu
    Yi-Ru, Lai
    Yu-Zen, Shen
    Chinese Pharmaceutical Journal, 1994, 46 (02):
  • [10] Determination of medrogestone in plasma by high-performance liquid chromatography
    Lin, WJ
    Her, SJ
    Chen, PF
    Chen, RRL
    JOURNAL OF CHROMATOGRAPHY B, 1998, 714 (02): : 263 - 268