Electrochemical Corrosion and Surface Analyses of a Ni-Cr Alloy in Bleaching Agents

被引:2
|
作者
Tamam, Evsen [1 ]
Aydin, A. Kevser [2 ]
Bilgic, Semra [3 ]
机构
[1] Gazi Univ, Dept Prosthodont, Fac Dent, TR-06510 Ankara, Turkey
[2] Ankara Univ, Dept Prosthodont, Fac Dent, TR-06100 Ankara, Turkey
[3] Ankara Univ, Dept Phys Chem, Fac Sci, TR-06100 Ankara, Turkey
关键词
Ni- Cr alloys; bleaching agents; corrosion; oxide layer; XPS; DENTAL CASTING ALLOYS; IN-VITRO; BEHAVIOR; TITANIUM; RELEASE; BIOCOMPATIBILITY; RESISTANCE; FLUORIDE; PH;
D O I
10.1111/jopr.12149
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim of this study was to evaluate the corrosion behavior of a Ni-Cr dental casting alloy subjected to 10% hydrogen peroxide (HP) and 10% carbamide peroxide (CP) bleaching solutions and to determine the composition of the surface oxide layer formed on the alloy specimens. Materials and MethodsTen cylindrical specimens (4 mm in diameter x 25 mm in height) were cast from a Ni-Cr alloy (Wiron 99) and divided into two groups (n = 5). A potentiodynamic polarization test was used to compare the corrosion rates of specimens in HP and CP (pH = 6.5). Before cyclic polarization tests, all alloy specimens were allowed to reach a steady open circuit potential (E-corr) for a period of 1 hour. Then tests were initiated at 100 mV versus standard calomel electrode (SCE) below E-corr and scanned at a rate of 1 mV/s in the anodic direction until reaching 1000 mV over the E-corr value. The scan then was reversed back to the E-corr of the specimens. The open circuit potentials (E-corr) and the current densities (I-corr) were determined using the anodic Tafel regions extrapolating from the curves. Differences in E-corr and I-corr were determined using one-way ANOVA ( = 0.05). In addition, corrosion rates were calculated from these curves. Before and after polarization tests, a scanning electron microscope (SEM) examination accompanied by energy dispersive X-ray spectroscopy (EDS) was used to analyze the surface morphology. The surface characterization of the passive film formed on alloy specimens was also performed by using X-ray photoelectron spectroscopy (XPS). ResultsIn this study, bleaching agents had an effect on the anodic process for two groups. Although no statistical difference was identified between the groups for both corrosion parameters, results indicated that the effect of CP on the corrosion behavior was less than that of HP. These results agreed with the SEM observations. XPS data showed that oxide layers formed on all groups contained mainly Cr2O3, NiO, and MoO3, and the amounts of oxides formed on CP-treated specimens were higher than HP treated ones. Also, molybdenum rates were increased with CP application compared to HP. ConclusionsThe comparison of the effects of the two bleaching agents at 10% showed that the alloy suffered less corrosion with CP than HP. This result was also confirmed by the SEM and XPS data. The presence of Mo on the oxide layer affected the oxide layer, leading to lower corrosion rates
引用
收藏
页码:549 / 558
页数:10
相关论文
共 50 条
  • [1] Surface characterization of passive film and elemental release analysis of a Ni-Cr alloy during bleaching, part I: effects of different bleaching agents
    Tamam, Evsen
    Aydin, A. Kevser
    [J]. CLINICAL ORAL INVESTIGATIONS, 2011, 15 (03) : 375 - 382
  • [2] ELECTROCHEMICAL STUDY OF CORROSION IN NI-CR DENTAL ALLOYS
    DEDEMICHELI, SM
    RIESGO, O
    [J]. BIOMATERIALS, 1982, 3 (04) : 209 - 212
  • [3] Study on the electrochemical behaviors of electrodepositing Ni-Cr alloy
    Xu, Lijian
    Du, JIngjing
    He, Nongyue
    He, Quanguo
    Tang, Jianxin
    Li, Song
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 30 - 30
  • [4] Effect of gallium on the corrosion susceptibility of an odontological Ni-Cr alloy
    Riesgo, O
    Vazquez, SM
    Duffo, GS
    [J]. REVISTA DE METALURGIA, 1996, 32 (05) : 310 - 313
  • [5] ON THE ELECTROCHEMICAL NATURE OF HOT-CORROSION ATTACK IN NI-CR ALLOYS
    SIVAKUMAR, R
    SAGAR, PK
    BHATIA, ML
    [J]. OXIDATION OF METALS, 1985, 24 (5-6): : 315 - 330
  • [6] Influence of Cr Content on the Microstructure and Electrochemical Corrosion in Plasma Cladding Ni-Cr Coatings
    Zhang, Wenya
    Wang, Canming
    Song, Qiang
    Cui, Hongzhi
    Feng, Xiaoli
    Zhang, Chunzhi
    [J]. METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2019, 50A (11): : 5410 - 5420
  • [7] Influence of Cr Content on the Microstructure and Electrochemical Corrosion in Plasma Cladding Ni-Cr Coatings
    Wenya Zhang
    Canming Wang
    Qiang Song
    Hongzhi Cui
    Xiaoli Feng
    Chunzhi Zhang
    [J]. Metallurgical and Materials Transactions A, 2019, 50 : 5410 - 5420
  • [8] Electrochemical detection of underivatized amino acids with a Ni-Cr alloy electrode
    Marioli, JM
    Sereno, LE
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (15) : 2505 - 2515
  • [9] NI ATOM STATE IN NI-CR ALLOY
    KALINOVICH, DF
    KOVENSKI.II
    SMOLIN, MD
    [J]. FIZIKA TVERDOGO TELA, 1972, 14 (12): : 3699 - 3700
  • [10] Density of Liquid Ni-Cr Alloy
    F.XiaoJoining and Welding Research Institute
    [J]. Journal of Materials Science & Technology, 2003, (01) : 16 - 18