Determination of mercury by intermittent flow electrochemical cold vapor generation coupled to atomic fluorescence spectrometry

被引:59
|
作者
Li, Xun
Wang, Zhenghao [1 ]
机构
[1] Beijing Normal Univ, Dept Chem, Beijing 100875, Peoples R China
[2] Gannan Normal Univ, Dept Chem & Life Sci, Ganzhou 341000, Peoples R China
基金
中国国家自然科学基金;
关键词
electrochemical cold vapor generation; atomic fluorescence spectrometry; intermittent flow; mercury;
D O I
10.1016/j.aca.2007.02.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for determination of mercury was developed using an intermittent flow electrochemical cold vapor generation coupled to atomic fluorescence spectrometry (IF-ECVG-AFS). The mercury vapor was generated on the surface of glassy carbon cathode in the flow cell. The operating conditions for the electrochemical generation of mercury vapor were investigated in detail, and the interferences from various ions were evaluated. Urder the optimized conditions, no evident memory effects of mercury were observed. The calibration curve was linear up to 5 mu g L-1 -Ig at 0.54A cm(-2). A detection limit of 1.2 ng L-1 Hg and a relative standard deviation of 1.8% for 1 mu gL(-1) Hg were obtained. The accuracy A method was verified by the determination of mercury in the certified reference human hair. The ECVG avoided the use of reductants, thereby greatly reducing the contamination sources. In addition, the manifold of IF-ECVG-AFS was simple and amenable to automation. (c) 2007 Elsevier B. V. All rights reserved.
引用
收藏
页码:179 / 183
页数:5
相关论文
共 50 条
  • [1] Determination of mercury(II) ion by electrochemical cold vapor generation atomic absorption spectrometry
    Arbab-Zavar, MH
    Rounaghi, GH
    Chamsaz, M
    Masrournia, M
    ANALYTICAL SCIENCES, 2003, 19 (05) : 743 - 746
  • [2] Determination of Mercury(II) Ion by Electrochemical Cold Vapor Generation Atomic Absorption Spectrometry
    M. Hosein Arbab-Zavar
    G. Hosein Rounaghi
    Mahmoud Chamsaz
    Mahboube Masrournia
    Analytical Sciences, 2003, 19 : 743 - 746
  • [3] Ultra-trace determination of methylmercuy in seafood by atomic fluorescence spectrometry coupled with electrochemical cold vapor generation
    Zu, Wenchuan
    Wang, Zhenghao
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 304 : 467 - 473
  • [4] Determination of mercury by electrochemical cold vapor generation atomic fluorescence spectrometry using polyaniline modified graphite electrode as cathode
    Jiang, Xianjuan
    Gan, Wuer
    Wan, Lingzhong
    Zhang, Hanchang
    He, Youzhao
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (02) : 171 - 175
  • [5] Cold Vapour Generation and Atomic Fluorescence Spectrometry for the Determination of Mercury
    Li, Yinke
    Xu, Yirang
    Huang, Yun
    Dai, Yun
    Hu, Qiufen
    Yang, Guangyu
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (04) : 2893 - 2897
  • [6] SELECTIVE DETERMINATION OF INORGANIC AND TOTAL MERCURY BY COLD VAPOR ATOMIC FLUORESCENCE SPECTROMETRY COUPLED WITH FLOW-INJECTION ANALYSIS
    MORITA, H
    SUGIMOTO, M
    SHIMOMURA, S
    ANALYTICAL SCIENCES, 1990, 6 (01) : 91 - 95
  • [7] Determination of mercury in radioactive samples by cold vapor atomic fluorescence spectrometry
    Jasperson, MN
    Drake, LR
    PLUTONIUM FUTURES-THE SCIENCE, 2000, 532 : 350 - 351
  • [8] DETERMINATION OF MERCURY BY FLOW-INJECTION ATOMIC FLUORESCENCE SPECTROMETRY USING CHROMIUM(II) REDUCTION COLD VAPOR GENERATION
    TANAKA, H
    KOUNO, M
    MORITA, H
    OKAMOTO, K
    SHIMOMURA, S
    ANALYTICAL SCIENCES, 1992, 8 (06) : 857 - 861
  • [9] Reversible intermittent flow-injection determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry
    Neto, JAG
    Zara, LF
    Santos, A
    Rocha, JC
    Cardoso, AA
    LABORATORY ROBOTICS AND AUTOMATION, 1999, 11 (05) : 304 - 310
  • [10] Simultaneous determination of trace mercury and cadmium in tobacco samples by cold vapor generation-atomic fluorescence spectrometry
    Gan, WE
    Shi, WW
    Su, QD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (07) : 911 - 916