Interference between selenium and some trace elements during polarographic studies and its elimination

被引:8
|
作者
Somer, G [1 ]
Yilmaz, ÜT [1 ]
机构
[1] Gazi Univ, Fen Edebiyat Fak, TR-06500 Ankara, Turkey
关键词
interference; trace elements; selenite; elimination; determination; differential pulse polarography;
D O I
10.1016/j.talanta.2004.06.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When selenite was added into solutions of some ions such as copper, lead, cadmium, zinc, chromium and arsenic their DPP peak decreased. This kind of interference was observed in all acids and in wide range of pH values, causing at least 50% error when both ions (the ion present and selenite) were in similar quantities. It was found that this interference was not taking place at pH 8.5 in the presence of large amounts of selenite. A synthetic sample containing these elements in 10(-5) M in the presence of 50 times selenite has been analyzed at pH 8.5 without any interference. The detection limit in this medium was 3 x 10(-7) M for cadmium and lead, 1 x 10(-6) M for copper and zinc and it was 3 x 10 (7) M for selenite. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:598 / 602
页数:5
相关论文
共 50 条