Comparison of effective phacoemulsification time and corneal endothelial cell loss using three different ultrasound frequencies: A randomized controlled trial

被引:6
|
作者
Dewan, Taru [1 ,2 ]
Malik, Praveen K.
Tomar, Preeti
机构
[1] Atal Bihari Vajpayee Inst Med Sci, Dept Ophthalmol, New Delhi, India
[2] Dr Ram Manohar Lohia Hosp, New Delhi, India
关键词
Corneal endothelial cell loss; EPT; frequency; hard cataract; phacoemulsification; randomized controlled trial; resonant frequency; ultrasound; FREE-RADICALS; TRANSVERSAL; ENERGY;
D O I
10.4103/ijo.IJO_2163_21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Comparison of three ultrasound (US) frequencies for phacoemulsification of hard cataracts to determine a frequency that makes phacoemulsification more efficacious and safer. Methods: A randomized controlled trial was undertaken at a medical college and hospital. In total, 207 patients with grade 5.6-6.9 (LOCS III) senile cataract were randomized into three groups. Group I underwent phacoemulsification with 28-kHz frequency, group II with 42-kHz frequency, and group III with 53-kHz frequency. The effective phacoemulsification time (EPT) and estimated fluid usage (EFU) were compared intraoperatively. The endothelial cell parameters were analyzed for 6 months. Results: The groups were matched for age (P = 0.467), gender (P = 0.497), nuclear grade (P = 0.321), and anterior chamber depth (P = 0.635). The EPT and EFU were significantly lower in group III, compared to group II and group I, with P < 0.0001 and P < 0.0001, respectively. Postoperatively, the endothelial cell density (ECD) was significantly higher in group III at 1 month (P < 0.0001), 3 months (P < 0.0001), and 6 months (P < 0.0001). The percentages of ECD loss were also significantly lower in group III; the difference was statistically significant (P < 0.0001) up to 6 months postoperatively. Conclusion: Higher frequency ultrasound was associated with a lower EPT and EFU as well as better endothelial preservation than lower frequencies in hard cataracts.
引用
收藏
页码:1180 / 1185
页数:6
相关论文
共 50 条
  • [1] Comparison of effective phacoemulsification time and corneal endothelial cell loss using 2 ultrasound frequencies
    Dewan, Taru
    Malik, Praveen Kumar
    Kumari, Ritu
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09): : 1285 - 1293
  • [2] Comparison of corneal endothelial cell loss during phacoemulsification using continuous anterior chamber infusion versus those using ophthalmic viscosurgical device: Randomized controlled trial
    Nayak, B. K.
    Jain, Elesh Kumar
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2009, 57 (02) : 99 - 103
  • [3] Corneal Endothelial Cell Loss After Endocapsular and Supracapsular Phacoemulsification: The PERCEPOLIS Randomized Clinical Trial
    Knutsson, Karl Anders
    Paganoni, Giorgio
    Rama, Paolo
    [J]. CORNEA, 2023, 42 (03) : E6 - E6
  • [4] Corneal Endothelial Cell Loss After Endocapsular and Supracapsular Phacoemulsification: The PERCEPOLIS Randomized Clinical Trial
    Perone, Jean-Marc
    Ghetemme, Cedric
    Zevering, Yinka
    Zaidi, Mohamed
    Ouamara, Nadia
    Goetz, Christophe
    Lhuillier, Louis
    [J]. CORNEA, 2022, 41 (06) : 714 - 721
  • [5] Comparison of Corneal Endothelial Cell Changes after Phacoemulsification using Different Viscosurgical Devices
    Zhang, Hongyan
    Li, Mozhu
    Song, Xudong
    Song, Hongxin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [6] Letter Regarding: Corneal Endothelial Cell Loss After Endocapsular and Supracapsular Phacoemulsification: The PERCEPOLIS Randomized Clinical Trial
    Perone, Jean-Marc
    Goetz, Christophe
    Zevering, Yinka
    [J]. CORNEA, 2023, 42 (07) : E13 - E14
  • [7] Corneal endothelial cell loss after cataract extraction by using ultrasound phacoemulsification versus a fluid-based system
    Richard, Jerome
    Hoffart, Louis
    Chavane, Frederic
    Ridings, Bernard
    Conrath, John
    [J]. CORNEA, 2008, 27 (01) : 17 - 21
  • [8] Corneal endothelial cell loss after lens extraction using the fluid-based system compared to ultrasound phacoemulsification
    de Castro, LEF
    Sandoval, HP
    Vroman, DT
    Solomon, KD
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U160 - U160
  • [9] Comparison of the effects of ultrasound toothbrushes with different frequencies on oral hygiene: A randomized-controlled clinical trial
    Takenouchi, Akane
    Otani, Etsuyo
    Satoho, Yukiko
    Kakegawa, Yumiko
    Arai, Hiroe
    Matsukubo, Takashi
    [J]. INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2021, 19 (04) : 376 - 381
  • [10] CORNEAL ENDOTHELIAL-CELL LOSS AFTER PHACOEMULSIFICATION USING NUCLEAR CRACKING PROCEDURES
    HAYASHI, K
    NAKAO, F
    HAYASHI, F
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01): : 44 - 47