Surrogate based continuous noninvasive blood pressure measurement

被引:7
|
作者
Pielmus, Alexandru-Gabriel [1 ]
Muehlstef, Jens [2 ]
Bresch, Erik [2 ]
Glos, Martin [3 ]
Jungen, Christiane [4 ]
Mieke, Stefan [5 ]
Orglmeister, Reinhold [1 ]
Schulze, Andreas [2 ]
Stender, Birgit [6 ]
Voigt, Verena [7 ]
Zaunseder, Sebastian [8 ,9 ]
机构
[1] Tech Univ Berlin, Elect & Med Signal Proc, Einsteinufer 17, D-10587 Berlin, Germany
[2] Philips Res Europe, Res Grp Patient Care Solut, Eindhoven, Netherlands
[3] Charite Univ Med Berlin, Interdisciplinary Ctr Sleep Med, Berlin, Germany
[4] Univ Herz & Gefasszentrum UKE Hamburg, Klin & Poliklin Kardiol, Hamburg, Germany
[5] Phys Tech Bundesanstalt, Berlin, Germany
[6] Dragerwerk AG & Co KgaA, Lubeck, Germany
[7] Uniklin RWTH Aachen, Sekt Med Tech, Klin Anasthesiol, Aachen, Germany
[8] Tech Univ Dresden, Dresden, Germany
[9] Fachhsch Dortmund, Dortmund, Germany
来源
关键词
clinical; expert; guideline; NIBP; recommendation; workshop; PULSE TRANSIT-TIME; VELOCITY; VALIDATION;
D O I
10.1515/bmt-2020-0209
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arterial blood pressure is one of the most often measured vital parameters in clinical practice. State-of-the-art noninvasive ABP measurement technologies have noticeable limitations and are mainly based on uncomfortable techniques of complete or partial arterial occlusion by cuffs. Most commonplace devices provide only intermittent measurements, and continuous systems are bulky and difficult to apply correctly for nonprofessionals. Continuous cuffless ABP measurements are still an unmet clinical need and a topic of ongoing research, with only few commercially available devices. This paper discusses surrogate-based noninvasive blood pressure measurement techniques. It covers measurement methods of continuously and noninvasively inferring BP from surrogate signals without applying external pressures, except for reference or initialization purposes. The BP is estimated by processing signal features, so called surrogates, which are modulated by variations of BP. Discussed techniques include well-known approaches such as pulse transit time and pulse arrival time techniques, pulse wave analysis or combinations thereof. Despite a long research history, these methods have not found widespread use in clinical and ambulatory practice, in part due to technical limitations and the lack of a standardized regulatory framework. This work summarizes findings from an invited workshop of experts in the fields covering clinical expertise, engineering aspects, commercialization and standardization issues. The goal is to provide an application driven outlook, starting with clinical needs, and extending to technical actuality. It provides an outline of recommended research directions and includes a detailed overview of clinical use case scenarios for these technologies, opportunities, and limitations.
引用
收藏
页码:231 / 245
页数:15
相关论文
共 50 条
  • [1] A NOVEL CONTINUOUS AND NONINVASIVE MEASUREMENT FOR BLOOD PRESSURE BASED ON PHOTOPLETHYSMOGRAPHY
    Li, Xiru
    Li, Xiaofeng
    Xu, Jinlin
    Tan, Haibo
    Yuan, Munan
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [2] A novel art of continuous noninvasive blood pressure measurement
    Jürgen Fortin
    Dorothea E. Rogge
    Christian Fellner
    Doris Flotzinger
    Julian Grond
    Katja Lerche
    Bernd Saugel
    Nature Communications, 12
  • [3] NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT IN PSYCHOPHYSIOLOGY
    GODAERT, G
    KRUITWAGEN, J
    JASPERS, J
    PSYCHOPHYSIOLOGY, 1985, 22 (05) : 591 - 592
  • [4] A novel art of continuous noninvasive blood pressure measurement
    Fortin, Juergen
    Rogge, Dorothea E.
    Fellner, Christian
    Flotzinger, Doris
    Grond, Julian
    Lerche, Katja
    Saugel, Bernd
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [5] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [6] Development of a Noninvasive Continuous Blood Pressure Measurement and Monitoring System
    Islam, Md. Manirul
    Rafi, Fida Hasan Md.
    Mitul, Abu Farzan
    Ahmad, Mohiuddin
    Rashid, M. A.
    bin Abd Malek, Mohd Fareq
    2012 INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV), 2012, : 1085 - 1090
  • [7] Noninvasive Accelerometric Approach for Cuffless Continuous Blood Pressure Measurement
    Das, Mousumi
    Choudhary, Tilendra
    Sharma, L. N.
    Bhuyan, M. K.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [8] Architecture of Mobile and Desktop Stations for Noninvasive Continuous Blood Pressure Measurement
    Krejcar, Ondrej
    Janckulik, Dalibor
    Motalova, Leona
    Frischer, Robert
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 137 - +
  • [9] A Cluster Method to Noninvasive Continuous Blood Pressure Measurement Using PPG
    Miao, Yu
    Zhang, Zhiqiang
    Meng, Lifang
    Xie, Xiaoqin
    Pan, Haiwei
    SMART HEALTH, ICSH 2016, 2017, 10219 : 109 - 120
  • [10] APPLICATION IN PSYCHOPHYSIOLOGY OF A NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT METHOD
    GODAERT, G