Surface-enhanced molecularly imprinted electrochemiluminescence sensor based on Ru@SiO2 for ultrasensitive detection of fumonisin B1

被引:81
|
作者
Zhang, Wei [1 ,2 ]
Xiong, Huiwen [2 ]
Chen, Miaomiao [2 ]
Zhang, Xiuhua [1 ,2 ]
Wang, Shengfu [1 ,2 ]
机构
[1] Hubei Univ, Hubei Collaborat Innovat Ctr Adv Organ Chem Mat, Wuhan 430062, Peoples R China
[2] Hubei Univ, Coll Chem & Chem Engn, Minist Of Educ Key Lab Synth & Applicat Organ Fun, Wuhan 430062, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Electrochemiluminescence; Ru(bpy)(3)(2+)-doped silica nanoparticle; Fumonisin B-1; Gold-nanoparticles; Molecularly imprinted polymer; DOPED SILICA NANOPARTICLES; ELECTROGENERATED CHEMILUMINESCENCE; RU(BPY)(3)(2+); ELECTRODE; AMPLIFICATION; LUMINESCENCE; IMMUNOSENSOR; MICROEMULSION; SPECTROSCOPY; APTASENSOR;
D O I
10.1016/j.bios.2017.04.035
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel molecularly imprinted electrochemiluminescence (MIP-ECL) sensor based on Ru(bpy)(3)(2+)-doped silica nanoparticles (Ru@SiO2 NPs) is developed for highly sensitive detection of fumonisin B-1 (FB1). Gold-nanoparticles (AuNPs), Ru@SiO2 NPs with chitosan (CS) composites and a molecularly imprinted polymer (MIP) are assembled on a glassy carbon electrode (GCE) to fabricate an ECL platform step by step. AuNPs could greatly promote the ECL intensity and improve the analytical sensitivity according to the localized surface plasmon resonance (LSPR) and the electrochemical effect. In this surface-enhanced electrochemiluminescence (SEECL) system, AuNPs work as the LSPR source to improve the ECL intensity and Ru@SiO2 NPs are used as ECL luminophores. In the phosphate buffer solution (PBS), the evident anodic ECL of Ru@SiO2 on the above working electrode is observed in the presence of the template molecule fumonisin B-1 (FB1), which could act as the coreactant of Ru@SiO2 NPs due to the amino group of FB1. When the template molecules were eluted from the MIP, little coreactant was left, resulting in an apparent decrease of ECL signal. After the MIP-ECL sensor was incubated in FB1 solution, the template molecules rebound to the MIP surface, leading to the enhancement of ECL signal again. On the basis of these results, a facile MIP-ECL sensor has been successfully fabricated, which exhibited a linear range from 0.001 to 100 ng mL(-1) with a detection limit of 0.35 pg mL(-1) for FB1. Moreover, the proposed MIP-ECL sensor displayed an excellent application in real samples.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 50 条
  • [1] Surface-Enhanced Electrochemiluminescence of Ru@SiO2 for Ultrasensitive Detection of Carcinoembryonic Antigen
    Wang, Daifang
    Li, Yanyan
    Lin, Zhenyu
    Qiu, Bin
    Guo, Longhua
    ANALYTICAL CHEMISTRY, 2015, 87 (12) : 5966 - 5972
  • [2] Molecularly imprinted photoelectrochemical sensor for fumonisin B1 based on GO-CdS heterojunction
    Mao, Lebao
    Ji, Kailun
    Yao, Linli
    Xue, Xiaojie
    Wen, Wei
    Zhang, Xiuhua
    Wang, Shengfu
    BIOSENSORS & BIOELECTRONICS, 2019, 127 : 57 - 63
  • [3] A molecularly imprinted electrochemiluminescence sensor based on upconversion nanoparticles enhanced by electrodeposited rGO for selective and ultrasensitive detection of clenbuterol
    Jin, Xincui
    Fang, Guozhen
    Pan, Mingfei
    Yang, Yukun
    Bai, Xiaoyun
    Wang, Shuo
    BIOSENSORS & BIOELECTRONICS, 2018, 102 : 357 - 364
  • [4] Fabrication of molecularly imprinted polypyrrole /Ru@ethyl-SiO2 nanocomposite for the ultrasensitive electrochemiluminescence sensing of 17β-Estradiol
    Cao, Nian
    Zeng, Peng
    Zhao, Faqiong
    Zeng, Baizhao
    ELECTROCHIMICA ACTA, 2018, 291 : 18 - 23
  • [5] Sandwich magnetically imprinted immunosensor for electrochemiluminescence ultrasensing diethylstilbestrol based on enhanced luminescence of Ru@SiO2 by CdTe@ZnS quantum dots
    Zhao, Wen-Rui
    Xu, Yao-Hua
    Kang, Tian-Fang
    Zhang, Xiao
    Liu, Hao
    Ming, An-Jie
    Cheng, Shui-Yuan
    Wei, Feng
    BIOSENSORS & BIOELECTRONICS, 2020, 155
  • [6] A molecularly imprinted electrochemiluminescence sensor for ultrasensitive HIV-1 gene detection using EuS nanocrystals as luminophore
    Babamiri, Bahareh
    Salimi, Abdollah
    Hallaj, Rahman
    BIOSENSORS & BIOELECTRONICS, 2018, 117 : 332 - 339
  • [7] A surface-enhanced electrochemiluminescence sensor based on Au-SiO2 core-shell nanocomposites doped with Ru(bpy)32+ for the ultrasensitive detection of prostate-specific antigen in human serum
    Wang, Daifang
    Zhou, Jin
    Guo, Longhua
    Qiu, Bin
    Lin, Zhenyu
    ANALYST, 2020, 145 (01) : 132 - 138
  • [8] Molecularly imprinted polymer nanoparticle-based assay (MINA): application for fumonisin B1 determination
    Munawar, Hasim
    Smolinska-Kempisty, Katarzyna
    Cruz, Alvaro Garcia
    Canfarotta, Francesco
    Piletska, Elena
    Karim, Khalku
    Piletsky, Sergey A.
    ANALYST, 2018, 143 (14) : 3481 - 3488
  • [9] Determination of Fumonisin B1 in maize using molecularly imprinted polymer nanoparticles-based assay
    Munawar, Hasim
    Safaryan, Abeer H. M.
    De Girolamo, Annalisa
    Garcia-Cruz, Alvaro
    Marote, Pedro
    Karim, Kal
    Lippolis, Vincenzo
    Pascale, Michelangelo
    Piletsky, Sergey A.
    FOOD CHEMISTRY, 2019, 298
  • [10] Molecularly imprinted photoelectrochemical sensor for aflatoxin B1 detection based on organic/inorganic hybrid nanorod arrays
    Wang, Caiyun
    Wang, Hao
    Zhang, Meng
    Zeng, Baizhao
    Zhao, Faqiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 339