Visualization of ultrasound induced cavitation bubbles using the synchrotron x-ray Analyzer Based Imaging technique

被引:7
|
作者
Izadifar, Zahra [1 ]
Belev, George [2 ]
Izadifar, Mohammad [1 ]
Izadifar, Zohreh [1 ]
Chapman, Dean [1 ,3 ]
机构
[1] Univ Saskatchewan, Coll Engn, Div Biomed Engn, Saskatoon, SK S7N 5A9, Canada
[2] Univ Saskatchewan, Canadian Light Source Inc, Canadian Light Source Biomed Imaging & Therapy Be, Saskatoon, SK S7N 2V3, Canada
[3] Univ Saskatchewan, Saskatoon, SK S7N 5E5, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 23期
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
synchrotron; x-ray imaging; analyzer based imaging; phase contrast imaging; detection; ultrasound; cavitation bubble; INDUCED LUNG HEMORRHAGE; SUPERTHRESHOLD BEHAVIOR; SHOCK-WAVES; DAMAGE; EXPOSURE; RABBIT; CONTRAST; MOUSE; PIG;
D O I
10.1088/0031-9155/59/23/7541
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Observing cavitation bubbles deep within tissue is very difficult. The development of a method for probing cavitation, irrespective of its location in tissues, would improve the efficiency and application of ultrasound in the clinic. A synchrotron x-ray imaging technique, which is capable of detecting cavitation bubbles induced in water by a sonochemistry system, is reported here; this could possibly be extended to the study of therapeutic ultrasound in tissues. The two different x-ray imaging techniques of Analyzer Based Imaging (ABI) and phase contrast imaging (PCI) were examined in order to detect ultrasound induced cavitation bubbles. Cavitation was not observed by PCI, however it was detectable with ABI. Acoustic cavitation was imaged at six different acoustic power levels and six different locations through the acoustic beam in water at a fixed power level. The results indicate the potential utility of this technique for cavitation studies in tissues, but it is time consuming. This may be improved by optimizing the imaging method.
引用
收藏
页码:7541 / 7555
页数:15
相关论文
共 50 条
  • [1] Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit
    Zahra Izadifar
    George Belev
    Paul Babyn
    Dean Chapman
    BioMedical Engineering OnLine, 14
  • [2] Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit
    Izadifar, Zahra
    Belev, George
    Babyn, Paul
    Chapman, Dean
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [3] Synchrotron x-ray imaging of acoustic cavitation bubbles induced by acoustic excitation
    Jung, Sung Yong
    Park, Han Wook
    Park, Sung Ho
    Lee, Sang Joon
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (04)
  • [4] Synchrotron radiation X-ray imaging of cavitation bubbles in Al-Cu alloy melt
    Huang, Haijun
    Shu, Da
    Fu, Yanan
    Wang, Jun
    Sun, Baode
    ULTRASONICS SONOCHEMISTRY, 2014, 21 (04) : 1275 - 1278
  • [5] Synchrotron X-ray imaging of the onset of ultrasonic horn cavitation
    Biasiori-Poulanges, Luc
    Bourquard, Claire
    Lukic, Bratislav
    Broche, Ludovic
    Supponen, Outi
    ULTRASONICS SONOCHEMISTRY, 2023, 92
  • [6] In-situ synchrotron X-ray imaging of ultrasound (US)-generated bubbles: Influence of US frequency on microbubble cavitation for membrane fouling remediation
    Ehsani, Masoume
    Zhu, Ning
    Doan, Huu
    Lohi, Ali
    Abdelrasoul, Amira
    ULTRASONICS SONOCHEMISTRY, 2021, 77
  • [7] Synchrotron X-ray induced acoustic imaging
    Choi, Seongwook
    Park, Eun-Yeong
    Park, Sinyoung
    Kim, Jong Hyun
    Kim, Chulhong
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] Synchrotron X-ray induced acoustic imaging
    Seongwook Choi
    Eun-Yeong Park
    Sinyoung Park
    Jong Hyun Kim
    Chulhong Kim
    Scientific Reports, 11
  • [9] Effects of trapped air bubbles on frequency responses of the piezo-driven inkjet printheads and visualization of the bubbles using synchrotron X-ray
    Kim, Byung-Hun
    Kim, Tae-Gyun
    Lee, Tae-Kyung
    Kim, Sungwook
    Shin, Seung-Joo
    Kim, Seong-Jin
    Lee, Sang-Joon
    SENSORS AND ACTUATORS A-PHYSICAL, 2009, 154 (01) : 132 - 139
  • [10] In Situ Synchrotron X-ray Study of Ultrasound Cavitation and Its Effect on Solidification Microstructures
    Mi, Jiawei
    Tan, Dongyue
    Lee, Tung Lik
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2015, 46 (04): : 1615 - 1619