Dynamic simulation of air-source heat pump during hot-gas defrost

被引:62
|
作者
Liu, ZQ [1 ]
Tang, GF [1 ]
Zhao, FY [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Dept Bldg Environm & Serv Engn, Changsha 410082, Peoples R China
关键词
hot-gas defrost; dynamic simulation; refrigeration system; distributed model;
D O I
10.1016/S1359-4311(03)00002-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
The dynamic simulation of hot-gas defrost is a challenge and necessary to the simulation of a heat pump: A defrost model that bases itself on the fundamental conservation equations and experimental results is presented in this paper. The distributed model is used here for the details of evaporator and condenser that are important components during the reverse cycle defrost. For validation of the model, a test was set up which contained a nominal 0.88 kW capacity residential air-to-air heat pump that uses a capillary for expansion during the defrost. The good agreement between simulations and experimental results. shows that the dynamic defrost model can be used in the research of the heat pump especially for the reverse cycle-defrost. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
下载
收藏
页码:675 / 685
页数:11
相关论文
共 50 条
  • [1] Transient simulation of air-source heat pump during the reverse cycle defrost
    Liu, ZQ
    Tang, GF
    Zhao, FY
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 695 - 698
  • [2] An experimental investigation on hot gas defrost of air-source transcritical CO2 heat pump systems
    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an
    710049, China
    Hsi An Chiao Tung Ta Hsueh, 3 (74-79):
  • [3] Frost retardation of an air-source heat pump by the hot gas bypass method
    Byun, Ju-Suk
    Lee, Jinho
    Jeon, Chang-Duk
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (02): : 328 - 334
  • [4] DEFROST CYCLE PERFORMANCE FOR AN AIR-SOURCE HEAT-PUMP WITH A SCROLL AND A RECIPROCATING-COMPRESSOR
    PAYNE, V
    ONEAL, DL
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (02): : 107 - 112
  • [5] Application of a water-heat storage system for the prevention of duplex defrost using an air-source heat pump
    Lim, K. B.
    Lee, S. H.
    Lee, C. H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2010, 224 (E1) : 67 - 71
  • [6] Research on defrost free air-source heat pump with surface stripe concavo-convex fins
    Yajima, Takeshi
    Ohkubo, Hidetoshi
    Seki, Mitsuo
    ENERGY AND BUILDINGS, 2021, 231
  • [7] Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor
    Nutter, DW
    ONeal, D
    Payne, WV
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 1, 1996, 102 : 284 - 290
  • [8] Hot gas defrosting method for air-source transcritical CO2 heat pump systems
    Hu, Bin
    Yang, Dongfang
    Cao, Feng
    Xing, Ziwen
    Fei, Jiyou
    ENERGY AND BUILDINGS, 2015, 86 : 864 - 872
  • [9] Research on parallel hot water system of condensing air-source heat pump
    Jiang Y.
    Zeng Z.
    Bi L.
    Liu Y.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2019, 50 (09): : 2310 - 2316
  • [10] NEW AIR-SOURCE HEAT PUMP SYSTEM
    MATSUDA, T
    MIYAMOTO, S
    MINOSHIMA, Y
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (08): : 32 - 35