Diagnostic performance of angiography-derived fractional flow reserve: a systematic review and Bayesian meta-analysis

被引:129
|
作者
Collet, Carlos [1 ,2 ]
Onuma, Yoshinobu [3 ,4 ]
Sonck, Jeroen [2 ]
Asano, Taku [1 ]
Vandeloo, Bert [2 ]
Kornowski, Ran [5 ]
Tu, Shengxian [6 ]
Westra, Jelmer [7 ]
Holm, Niels R. [7 ]
Xu, Bo [8 ]
de Winter, Robbert J. [1 ]
Tijssen, Jan G. [1 ]
Miyazaki, Yosuke [4 ]
Katagiri, Yuki [1 ]
Tenekecioglu, Erhan [4 ]
Modolo, Rodrigo [1 ]
Chichareon, Ply [1 ]
Cosyns, Bernard [2 ]
Schoors, Daniel [2 ]
Roosens, Bram [2 ]
Lochy, Stijn [2 ]
Argacha, Jean-Francois [2 ]
van Rosendael, Alexandre [9 ]
Bax, Jeroen [9 ]
Reiber, Johan H. C. [10 ,11 ]
Escaned, Javier [12 ,13 ]
De Bruyne, Bernard [14 ]
Wijns, William [15 ,16 ]
Serruys, Patrick W. [17 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Cardiol, Amsterdam, Netherlands
[2] Univ Ziekenhuis Brussel, Dept Cardiol, Brussels, Belgium
[3] Cardialysis BV, Rotterdam, Netherlands
[4] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[5] Tel Aviv Univ, Sackler Fac Med, Belinson Hosp, Rabin Med Ctr,Cardiol Dept, Petah Tiqwa, Israel
[6] Shanghai Jiao Tong Univ, Biomed Instrument Inst, Sch Biomed Engn, Shanghai, Peoples R China
[7] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[8] Chinese Acad Med Sci, Natl Ctr Cardiovasc Dis, Fu Wai Hosp, Beijing, Peoples R China
[9] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
[10] LUMC, Dept Radiol, Div Image Proc LKEB, Leiden, Netherlands
[11] Medis Med Imaging Syst, Leiden, Netherlands
[12] Hosp Clinico San Carlos IDISSC, Madrid, Spain
[13] Univ Complutense Madrid, Madrid, Spain
[14] OLV Clin, Cardiovasc Ctr Aalst, Aalst, Belgium
[15] Natl Univ Ireland, Lambe Inst Translat Med & Curam, Galway, Ireland
[16] Saolta Univ Healthcare Grp, Galway, Ireland
[17] Imperial Coll London, Dept Cardiol, London, England
关键词
3DQCA; Conventional angiography; Ischaemia; Significant lesion; QUANTITATIVE CORONARY-ANGIOGRAPHY; FUNCTIONAL ASSESSMENT; LESIONS; ACCURACY; STENOSES; COMPUTATION; ARTERY; WIRE;
D O I
10.1093/eurheartj/ehy445
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease Methods and results A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages Conclusion The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.
引用
收藏
页码:3314 / +
页数:9
相关论文
共 50 条
  • [1] Diagnostic performance of angiography-derived fractional flow reserve and CT-derived fractional flow reserve: A systematic review and Bayesian network meta-analysis
    Chen, Zhongxiu
    Zhang, Junyan
    Cai, Yujia
    Zhao, Hongsen
    Wang, Duolao
    Li, Chen
    He, Yong
    JOURNAL OF EVIDENCE BASED MEDICINE, 2024, 17 (01) : 119 - 133
  • [3] Diagnostic performance of angiography-derived fractional flow reserve in patients with NSTEMI
    Skalidis, Ioannis
    Meier, David
    De Bruyne, Bernard
    Collet, Carlos
    Sonck, Jeroen
    Mahendiran, Thabo
    Rotzinger, David
    Qanadli, Salah Dine
    Eeckhout, Eric
    Muller, Olivier
    Fournier, Stephane
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 101 (02) : 308 - 315
  • [4] Prognostic Value of Post-PCI Angiography-Derived Fractional Flow Reserve: A Systematic Review and Meta-Analysis of Cohort Studies
    Terentes-Printzios, Dimitrios
    Gkini, Konstantia-Paraskevi
    Oikonomou, Dimitrios
    Gardikioti, Vasiliki
    Aznaouridis, Konstantinos
    Dima, Ioanna
    Tsioufis, Konstantinos
    Vlachopoulos, Charalambos
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (08):
  • [5] Diagnostic performance of angiography-derived index of microvascular resistance: a systematic review and pooled meta-analysis
    Zhou, J.
    Onuma, Y.
    Kotoku, N.
    Kageyama, S.
    Ninomiya, K.
    Masuda, S.
    Yan, H.
    Serruys, P.
    EUROPEAN HEART JOURNAL, 2022, 43 : 2007 - 2007
  • [6] Computed tomography angiography-derived fractional flow reserve (CT-FFR) for the detection of myocardial ischemia with invasive fractional flow reserve as reference: systematic review and meta-analysis
    Zhuang, Baiyan
    Wang, Shuli
    Zhao, Shihua
    Lu, Minjie
    EUROPEAN RADIOLOGY, 2020, 30 (02) : 712 - 725
  • [7] Computed tomography angiography-derived fractional flow reserve (CT-FFR) for the detection of myocardial ischemia with invasive fractional flow reserve as reference: systematic review and meta-analysis
    Baiyan Zhuang
    Shuli Wang
    Shihua Zhao
    Minjie Lu
    European Radiology, 2020, 30 : 712 - 725
  • [8] Computed Tomography Angiography-Derived Fractional Flow Reserve (CT-FFR) for the Detection of Myocardial Ischemia-with Invasive Fractional Flow Reserve as Reference: Systematic Review and Meta-Analysis
    Zhuang, Baiyan
    Wang, Shuli
    Zhao, Shihua
    Sirajuddin, Arlene
    Andrew, Arai E.
    Lu, Minjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C200 - C201
  • [9] Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in coronary artery disease: A systematic review and meta-analysis
    Deng, Song-Bai
    Jing, Xiao-Dong
    Wang, Jing
    Huang, Chuan
    Xia, Shuang
    Du, Jian-Lin
    Liu, Ya-Jie
    She, Qiang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 184 : 703 - 709
  • [10] Diagnostic accuracy of coronary computed tomography angiography-derived fractional flow reserve
    Wenbing Jiang
    Yibin Pan
    Yumeng Hu
    Xiaochang Leng
    Jun Jiang
    Li Feng
    Yongqing Xia
    Yong Sun
    Jian’an Wang
    Jianping Xiang
    Changling Li
    BioMedical Engineering OnLine, 20