Performance comparison of small-pixel CdZnTe radiation detectors with gold contacts formed by sputter and electroless deposition

被引:2
|
作者
Bell, S. J. [1 ,2 ,3 ]
Baker, M. A. [2 ]
Duarte, D. D. [1 ,2 ]
Schneider, A. [1 ]
Seller, P. [1 ]
Sellin, P. J. [2 ]
Veale, M. C. [1 ]
Wilson, M. D. [1 ]
机构
[1] Rutherford Appleton Lab, Harwell OX11 0QX, Oxon, England
[2] Univ Surrey, Fac Engn & Phys Sci, Guildford GU2 7XH, Surrey, England
[3] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, Middx, England
来源
基金
英国工程与自然科学研究理事会;
关键词
Gamma detectors (scintillators; CZT; HPG; HgI etc); Hybrid detectors; Materials for solid-state detectors; X-ray detectors; CADMIUM ZINC TELLURIDE; CHARGE; CDTE;
D O I
10.1088/1748-0221/12/06/P06015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent improvements in the growth of wide-bandgap semiconductors, such as cadmium zinc telluride (CdZnTe or CZT), has enabled spectroscopic X/gamma-ray imaging detectors to be developed. These detectors have applications covering homeland security, industrial analysis, space science and medical imaging. At the Rutherford Appleton Laboratory (RAL) a promising range of spectroscopic, position sensitive, small-pixel Cd(Zn) Te detectors have been developed. The challenge now is to improve the quality of metal contacts on CdZnTe in order to meet the demanding energy and spatial resolution requirements of these applications. The choice of metal deposition method and fabrication process are of fundamental importance. Presented is a comparison of two CdZnTe detectors with contacts formed by sputter and electroless deposition. The detectors were fabricated with a 74 x 74 array of 200 mu m pixels on a 250 mu m pitch and bump-bonded to the HEXITEC ASIC. The X/gamma-ray emissions from an Am-241 source were measured to form energy spectra for comparison. It was found that the detector with contacts formed by electroless deposition produced the best uniformity and energy resolution; the best pixel produced a FWHM of 560 eV at 59.54 keV and 50% of pixels produced a FWHM better than 1.7 keV. This compared with a FWHM of 1.5 keV for the best pixel and 50% of pixels better than 4.4 keV for the detector with sputtered contacts.
引用
收藏
页数:11
相关论文
共 10 条
  • [1] Comparison of the surfaces and interfaces formed for sputter and electroless deposited gold contacts on CdZnTe
    Bell, Steven J.
    Baker, Mark A.
    Duarte, Diana D.
    Schneider, Andreas
    Seller, Paul
    Sellin, Paul J.
    Veale, Matthew C.
    Wilson, Matthew D.
    APPLIED SURFACE SCIENCE, 2018, 427 : 1257 - 1270
  • [2] Characterization of the metal-semiconductor interface of gold contacts on CdZnTe formed by electroless deposition
    Bell, Steven J.
    Baker, Mark A.
    Duarte, Diana D.
    Schneider, Andreas
    Seller, Paul
    Sellin, Paul J.
    Veale, Matthew C.
    Wilson, Matthew D.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2015, 48 (27)
  • [3] Comparison of radiation detector performance for different metal contacts on CdZnTe deposited by electroless deposition method
    Zheng, Q.
    Dierre, F.
    Ayoub, M.
    Crocco, J.
    Bensalah, H.
    Corregidor, V.
    Alves, E.
    Fernandez-Ruiz, R.
    Perez, J. M.
    Dieguez, E.
    CRYSTAL RESEARCH AND TECHNOLOGY, 2011, 46 (11) : 1131 - 1136
  • [4] A multi-technique characterization of electroless gold contacts on single crystal CdZnTe radiation detectors
    Bell, S. J.
    Baker, M. A.
    Chen, H.
    Marthandam, P.
    Perumal, V.
    Schneider, A.
    Seller, P.
    Sellin, P. J.
    Veale, M. C.
    Wilson, M. D.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (45)
  • [5] Electroless gold contact deposition on CdZnTe detectors by scanning pipette technique
    Zambelli, N.
    Marchini, L.
    Benassi, G.
    Calestani, D.
    Caroli, E.
    Zappettini, A.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [6] Mechanically Stable Metal Layers for Ohmic and Blocking Contacts on CdZnTe Detectors by Electroless Deposition
    Bettelli, M.
    Benassi, G.
    Nasi, L.
    Zambelli, N.
    Zappettini, A.
    Gombia, E.
    Abbene, L.
    Principato, F.
    Calestani, D.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [7] Performance Comparison of Steering-Grid and Simple-Pixel CdZnTe Detectors
    Zhu, Yuefeng
    Zhang, F.
    Boucher, Y. A.
    Mann, J.
    He, Zhong
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] Comparison of the X-Ray Performance of Small Pixel CdTe and CZT Detectors
    Wilson, Matthew D.
    Barnes, Paul
    Cernik, Robert C.
    Hansson, Conny C. T.
    Jacques, Simon
    Jones, Lawrence L.
    Seller, Paul
    Sellin, Paul J.
    Sochi, Taha
    Veale, Matthew C.
    Veeramani, Peruami
    Withers, Philip J.
    Youd, Christopher P.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3942 - 3946
  • [9] Performance comparison of Si-PM-based block detectors with different pixel sizes for an ultrahigh-resolution small-animal PET system
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Hatazawa, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : N227 - N236
  • [10] Design and Feasibility Study of a Full-Ring X-ray Fluorescence Emission Computed Tomography System based on Small-Pixel CdTe Detectors for Real-Time Monitoring of X-ray Induced and Nanoparticle Mediated Radiation Therapy
    Giannoni, Luca
    George, Jonathan
    Lai, Xiaochun
    Meng, Ling-Jian
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57