Impact of delivery characteristics on dose delivery accuracy of volumetric modulated arc therapy for different treatment sites

被引:10
|
作者
Li, Jiaqi [1 ]
Zhang, Xile [1 ]
Li, Jun [1 ]
Jiang, Rongtao [2 ,3 ]
Sui, Jing [2 ,3 ]
Chan, Maria F. [4 ]
Yang, Ruijie [1 ]
机构
[1] Peking Univ Third Hosp, Dept Radiat Oncol, 49 North Garden Rd, Beijing, Peoples R China
[2] Chinese Acad Sci, Brainnetome Ctr, Beijing, Peoples R China
[3] Chinese Acad Sci, Natl Lab Pattern Recognit, Inst Automat, Beijing, Peoples R China
[4] Mem Sloan Kettering Canc Ctr, Med Phys Dept, 1275 York Ave, New York, NY 10021 USA
基金
美国国家卫生研究院; 中国国家自然科学基金;
关键词
complexity metrics; volumetric modulated arc therapy; quality assurance; gamma passing rate; RADIATION-THERAPY; QUALITY-ASSURANCE; PLAN QUALITY; IMRT; QA; COMPLEXITY; RADIOTHERAPY; ERRORS; VERIFICATION; VALIDATION;
D O I
10.1093/jrr/rrz033
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to investigate the impact of delivery characteristics on the dose delivery accuracy of volumetric modulated arc therapy (VMAT) for different treatment sites. The pretreatment quality assurance (QA) results of 344 VMAT patients diagnosed with gynecological (GYN), head and neck (H&N), rectal or prostate cancer were randomly chosen in this study. Ten metrics reflecting VMAT delivery characteristics were extracted from the QA plans. Compared with GYN and rectal plans, H&N and prostate plans had higher aperture complexity and monitor units (MU), and smaller aperture area. Prostate plans had the smallest aperture area and lowest leaf speed compared with other plans (P < 0.001). No differences in gantry speed were found among the four sites. The gamma passing rates (GPRs) of GYN, rectal and H&N plans were inversely associated with union aperture area (UAA) and leaf speed (Pearson's r: -0.39 to -0.68). GPRs of prostate plans were inversely correlated with aperture complexity, MU and small aperture score (SAS) (absolute Pearson's r: 0.34 to 0.49). Significant differences in GPR between high SAS and low SAS subgroups were found only when leaf speed was <0.42 cm s(-1) (P < 0.001). No association of GPR with gantry speed was found in four sites. Leaf speed was more strongly associated with UAA. Aperture complexity and MU were more strongly associated with SAS. VMAT plans from different sites have distinct delivery characteristics. Affecting dose delivery accuracy, leaf speed is the key factor for GYN, rectal and H&N plans, while aperture complexity, MU and small apertures have a higher influence on prostate plans.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 50 条
  • [1] Impact of Delivery Characteristics On Dose Delivery Accuracy of Volumetric Modulated Arc Therapy for Different Treatment Sites
    Li, J.
    Zhang, X.
    Li, J.
    Jiang, R.
    Sui, J.
    Chan, M.
    Yang, R.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E484 - E484
  • [2] Improving Delivery Accuracy of Volumetric Modulated Arc Therapy (VMAT)
    Ye, J.
    Rao, M.
    Chen, F.
    Cao, D.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2421 - +
  • [3] Impact of Plan Complexity On the Delivery Accuracy and Dosimetric Accuracy of Volumetric-Modulated Arc Therapy
    Li, G.
    Li, Y.
    Wang, Q.
    Xiao, J.
    Bai, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2892 - 2892
  • [4] Impact of small MU/segment and dose rate on delivery accuracy of volumetric-modulated arc therapy (VMAT)
    Huang, Long
    Zhuang, Tingliang
    Mastroianni, Anthony
    Djemil, Toufik
    Cui, Taoran
    Xia, Ping
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 203 - 210
  • [5] Modulation indices and plan delivery accuracy of volumetric modulated arc therapy
    Park, Jong Min
    Kim, Jung-in
    Park, So-Yeon
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 12 - 22
  • [6] Evaluating the delivery accuracy of volumetric modulated arc therapy (VMAT) treatments
    Scaggion, A.
    Negri, A.
    Paiusco, M.
    Rossato, M. A.
    Roggio, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S154 - S155
  • [7] The Effect of Dose Rate Decrease and Speed Variation on the Delivery Accuracy of a Volumetric Modulated Arc Therapy Plan
    Wang, K.
    Feng, Y.
    Jin, J.
    Cao, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E617 - E618
  • [8] Potential impact of volumetric modulated arc therapy on the planning and delivery of radiation therapy
    Matuszak, M. M.
    Sui, H.
    Yan, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S651 - S651
  • [9] Impact of beam complexity on plan delivery accuracy verification of a transmission detector in volumetric modulated arc therapy
    Radici, Lorenzo
    Petrucci, Edoardo
    Borca, Valeria Casanova
    Cante, Domenico
    Piva, Cristina
    Pasquino, Massimo
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 122