Outcomes of Cemented Distal Femoral Replacement Using "Line to Line" Technique With All-Polyethylene Tibial Implant for Tumors

被引:5
|
作者
Tayara, Bader [1 ,3 ]
Nooh, Anas [1 ,3 ]
Chalopin, Antoine [1 ,3 ]
Goulding, Krista [2 ]
Turcotte, Robert E. [1 ,3 ]
机构
[1] McGill Univ, Dept Orthoped Surg, Hlth Ctr, Montreal, PQ, Canada
[2] Mayo Clin, Dept Orthoped Surg, Phoenix, AZ USA
[3] McGill Univ, Hlth Ctr, 1650 Cedar Ave,Montreal Gen Hosp Site, Montreal, PQ H3G 1A4, Canada
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 08期
关键词
oncology; sarcoma; endoprosthesis; French paradox; distal femur replacement; LONG-TERM SURVIVAL; CUSTOM-MADE; FRENCH PARADOX; BONE-TUMORS; ENDOPROSTHETIC RECONSTRUCTION; HIP-ARTHROPLASTY; ROTATING HINGE; FOLLOW-UP; KNEE; MANTLE;
D O I
10.1016/j.arth.2021.03.033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Both cemented and cementless stemmed endoprosthetic implants have been used to reconstruct large skeletal defects after tumor resection with similar outcomes. In this study, we examined the oncologic, clinical, and functional outcomes in patients undergoing distal femur replacement using the French paradox technique. Methods: A total of 125 patients who underwent distal femur replacement between 1990 and 2019 using the line-to-line cementation technique were reviewed. Implant failure was recorded as per Henderson's classification. Functional outcomes were analyzed using the Musculoskeletal Tumor Society and Toronto Extremity Salvage Score scoring systems. The mean follow-up was 84 (1-350) months. Results: Aseptic loosening of the femoral stem was recorded in one patient at 21-years of follow-up. Twenty of 125 patients required bushing exchange for polyethylene wear, all after 10 years. Six tibial bearing component fractures were recorded in four patients while one femoral stem component Morse taper fractured. Two all-polyethylene cemented tibial implants were revised for polyethylene granuloma. Deep surgical site infection occurred in 13 patients, while six patients experienced local recurrence. Kaplan-Meier estimates for implant survival for all-cause revision were 85% at 1 year and 70% at 5 years. These estimates for femur or tibia loosening as an end point were 96% at 10 years and 90% at 15 years. The mean Musculoskeletal Tumor Society and Toronto Extremity Salvage Score scores at the last followup were 76% and 74%, respectively. Thirty-five patients died of disease progression. Conclusion: The line-to-line cementation technique, used with all-polyethylene tibial implants, demonstrates low incidence of aseptic loosening at medium and long-term follow-ups. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:2913 / 2920
页数:8
相关论文
共 8 条
  • [1] Clinical outcomes of cemented distal femur replacements with all-polyethylene tibial components for oncologic indications
    Christ, Alexander B.
    Chung, Brian C.
    Urness, Matthew
    Mayer, Lucas W.
    Gettleman, Brandon S.
    Heckmann, Nathanael D.
    Menendez, Lawrence R.
    WORLD JOURNAL OF ORTHOPEDICS, 2023, 14 (04): : 218 - 230
  • [2] Retention of all-polyethylene acetabular components after femoral revision of a cemented total hip replacement
    Hamlin, BR
    Rowland, C
    Morrey, BF
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11): : 1700 - 1705
  • [3] The role of the cemented all-polyethylene tibial component in total knee replacement A 30-year patient follow-up and review of the literature
    Blumenfeld, Thomas J.
    Scott, Richard D.
    KNEE, 2010, 17 (06): : 412 - 416
  • [4] Long-Term Results of Total Knee Replacement Using PFC Sigma System with an All-Polyethylene Tibial Component
    Nachtnebl, L.
    Tomas, T.
    Apostolopoulos, V
    Pazourek, L.
    Mahdal, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2021, 88 (06) : 412 - 417
  • [5] Limb-salvage treatment of en-block resected distal femoral tumors with endoprosthesis of all-polyethylene tibial component: a 9-year follow-up study
    Tang, Fan
    Zhou, Yong
    Min, Li
    Zhang, Wenli
    Shi, Rui
    Luo, Yi
    Duan, Hong
    Tu, Chongqi
    ONCOTARGETS AND THERAPY, 2016, 9 : 5361 - 5369
  • [6] All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes
    Fan Tang
    Yong Zhou
    Wenli Zhang
    Li Min
    Rui Shi
    Yi Luo
    Hong Duan
    Chongqi Tu
    Journal of Orthopaedic Surgery and Research, 12
  • [7] All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes
    Tang, Fan
    Zhou, Yong
    Zhang, Wenli
    Min, Li
    Shi, Rui
    Luo, Yi
    Duan, Hong
    Tu, Chongqi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [8] Implant Preference and Clinical Outcomes of Patients with Staged Bilateral Total Knee Arthroplasty: All-Polyethylene and Contralateral Metal-Backed Tibial Components
    Nachtnebl, Lubos
    Apostolopoulos, Vasileios
    Mahdal, Michal
    Pazourek, Lukas
    Brancik, Pavel
    Valousek, Tomas
    Bohac, Petr
    Tomas, Tomas
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)