Application of cast magnetic attachments to sectional complete dentures for a patient with microstomia: A clinical report

被引:24
|
作者
Watanabe, I
Tanaka, Y
Ohkubo, C
Miller, AW
机构
[1] Texas A&M Univ Syst, Hlth Sci Ctr, Dept Biomat Sci, Baylor Coll Dent, Dallas, TX 75246 USA
[2] Nagasaki Univ, Sch Dent, Nagasaki 852, Japan
[3] Tsurumi Univ, Sch Dent Med, Yokohama, Kanagawa, Japan
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2002年 / 88卷 / 06期
关键词
D O I
10.1067/mpr.2002.130095
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Patients with microstomia who must wear removable dental prostheses often state that they are unable to insert or remove the prosthesis because of the constricted opening of the oral cavity. This article presents a cast iron-platinum magnetic attachment system applied to sectional collapsed complete dentures for an edentulous patient with microstomia. With the use of lingual and palatal midline hinges and a cast iron-platinum magnetic attachment, the sectional prosthesis was successfully and easily inserted and provided adequate function in the patient's mouth.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 50 条
  • [1] Fabrication of a sectional impression tray and sectional complete denture for a patient with microstomia and trismus: A clinical report
    Cura, C
    Cotert, HS
    User, A
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (06): : 540 - 543
  • [2] Fabricating sectional-collapsible complete dentures for an edentulous patient with microstomia induced by scleroderma
    Dikbas, Idil
    Koksal, Temel
    Kazazoglu, Ender
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (01): : 15 - 22
  • [3] Application of a custom-made inlay structure to a sectional maxillary complete denture for a patient with microstomia: A clinical report
    Sun, Jian
    Jiao, Ting
    Jiang, Yong-lin
    Zhang, Fu-Qiang
    [J]. QUINTESSENCE INTERNATIONAL, 2012, 43 (09): : 789 - 791
  • [4] A SECTIONAL COMPLETE DENTURE FOR A PATIENT WITH MICROSTOMIA
    MCCORD, JF
    TYSON, KW
    BLAIR, IS
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1989, 61 (06): : 645 - 647
  • [5] Impression procedures and construction of a sectional denture for a patient with microstomia: A clinical report
    Geckili, Onur
    Cilingir, Altug
    Bilgin, Tayfun
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (06): : 387 - 390
  • [6] Sectional collapsed denture for a partially edentulous patient with microstomia: A clinical report
    Suzuki, Y
    Abe, M
    Hosoi, T
    Kurtz, KS
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (03): : 256 - 259
  • [7] Sectional collapsible complete removable dental prosthesis for a patient with microstomia
    Sinavarat, Potchaman
    Anunmana, Chuchai
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05): : 627 - 632
  • [8] Prosthetic rehabilitation for a patient with microstomia: A clinical report
    Benetti, R
    Zupi, A
    Toffanin, A
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (04): : 322 - 327
  • [9] Fabrication of conventional complete dentures for a left segmental mandibulectomy patient: A clinical report
    Mou, SH
    Chai, T
    Shiau, YY
    Wang, JS
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (06): : 582 - 585
  • [10] Effect of Complete Dentures on Craniofacial Growth of an Ectodermal Dysplasia Patient: A Clinical Report
    Bhalla, Gaurav
    Agrawal, Kaushal Kishor
    Chand, Pooran
    Singh, Kamleshwar
    Singh, Balandra Pratap
    Goel, Prachi
    Alvi, Habib Ahmed
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (06): : 495 - 500