A Compact Flexible Thermal Flow Sensor for Detecting Two-Dimensional Flow Vector

被引:30
|
作者
Que, Rui-Yi [1 ]
Zhu, Rong [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
关键词
Two-dimensional flow measurement; flexible; thermal flow sensor; FLUID-MECHANICS; SENSITIVITY; DIRECTION; SYSTEM; ARRAY; MODEL;
D O I
10.1109/JSEN.2014.2367017
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel compact flexible thermal flow sensor on a polyimide (PI) substrate for detecting parameters of a two-dimensional (2-D) flow vector over a full range of 360 degrees. Three or more thermal elements patterned as equally divided sectors of a round on a PI substrate compose the sensor probe, of which the three-element structure is the simplest design for 2-D flow detection. Each element works in constant temperature difference (CTD) mode, all of which form a common round CTD area while the heat power loss for each element is detected separately. The sensor probe contains thin-film Pt elements distributed in a round with a diameter of 2 mm fabricated on a flexible substrate using micromachining technique. Using a neural network to execute data fusion, the velocity and direction angle of the flow are deduced from the readouts of the sensor elements. Validities of the three-element and four-element designs were proven through experiments. Experimental results show that for the three-element sensor, the mean square error of the flow velocity reaches 0.65 m/s in the range of 3-30 m/s and the error of the flow direction reaches 2.69 degrees in the range of 0 degrees-360 degrees. For four-element sensor in the same ranges of measurement, the mean square errors of the flow velocity and flow direction angle reach 0.59 m/s and 0.96 degrees, respectively.
引用
收藏
页码:1931 / 1936
页数:6
相关论文
共 50 条
  • [1] TWO-DIMENSIONAL FLOW AT RIGHT ANGLES TO A FLEXIBLE MEMBRANE
    NEWMAN, BG
    LOW, HT
    AERONAUTICAL QUARTERLY, 1981, 32 (AUG): : 243 - 269
  • [2] Constant power operation of a two-dimensional flow sensor
    Makinwa, KAA
    Huijsing, JH
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (04) : 840 - 844
  • [3] Unsteady two-dimensional analytical model for a thermal time-of-flight flow sensor
    El Fil, Bachir
    Mahvi, Allison J.
    Garimella, Srinivas
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 134 : 329 - 337
  • [4] Two-Dimensional CMOS MEMS Thermal Flow Sensor With High Sensitivity and Improved Accuracy
    Xu, Wei
    Wang, Xiaoyi
    Zhao, Xu
    Lee, Yi-Kuen
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2020, 29 (02) : 248 - 254
  • [5] Comparison of performances of vortex flow sensor in two-dimensional and three-dimensional flow field
    School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2009, 9 (802-807):
  • [6] Transfer of a passive vector admixture by a two-dimensional turbulent flow
    Novikov, SV
    THEORETICAL AND MATHEMATICAL PHYSICS, 2003, 136 (01) : 936 - 950
  • [7] Transfer of a Passive Vector Admixture by a Two-Dimensional Turbulent Flow
    S. V. Novikov
    Theoretical and Mathematical Physics, 2003, 136 : 936 - 950
  • [8] A two-dimensional model for quasigeostrophic flow: Comparison with the two-dimensional Euler flow
    Majda, AJ
    Tabak, EG
    PHYSICA D-NONLINEAR PHENOMENA, 1996, 98 (2-4) : 515 - 522
  • [9] TWO-DIMENSIONAL FLOW AT RIGHT ANGLES TO A FLEXIBLE MEMBRANE.
    Newman, B.G.
    Low, H.T.
    Aeronautical Quarterly, 1981, 32 (pt 3): : 243 - 269
  • [10] Turbulent two-dimensional flow around a flexible membrane airfoil
    Bunge, U
    Rung, T
    Thiele, F
    NEW RESULTS IN NUMERICAL AND EXPERIMENTAL FLUID MECHANICS III, 2002, 77 : 273 - 280