Dynamic surface tensiometry of tissues using Langmuir films

被引:7
|
作者
Preetha, A
Banerjee, R [1 ]
Huilgol, N
机构
[1] Indian Inst Technol, Sch Biosci & Bioengn, Bombay 400076, Maharashtra, India
[2] Nanavati Hosp, Div Radiat Oncol, Bombay, Maharashtra, India
关键词
tissue monolayer; surface pressure-area isotherm; hysteresis; lift off area; limiting area; minimum surface tension;
D O I
10.1016/j.colsurfb.2004.10.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Langmuir monolayers are useful models of biomembranes as they allow, simulation of biological conditions and rigorous thermodynamic analysis. This technique was used to characterize tissues at body temperature for the first time in our study. The organs studied include liver. kidney, stomach, testis, heart and brain from goat and certain human cancerous as well as their corresponding normal biopsies to reveal the potential of the tissue monolayer technique. Monolayers were formed on the surface of deionized water by spreading monolayer amounts of the, tissue homogenates. The parameters calculated were minimum surface tension. relative lift off area. relative limiting area, compressibility and hysteresis area. Our results reveal that the parameters can differentiate between tissues obtained from different organs and were statistically significant using one-way ANOVA and Newman Keul's test (P < 0.05). For example goat's stomach tissue had the lowest hysteresis area (DeltaG) value (27.6 muL) whereas brain DeltaG value was nine folds higher than stomach value. Brain had the lowest minimum surface tension of 30.3 +/- 1.0 mN/m whereas stomach had a value of 40.5 +/- 0.2 mN/m. Interestingly. the DeltaG values of human normal neck and esophageal tissues were 3.4 and 3.2 folds greater than that of their respective cancer tissues whereas the DeltaG values of vulval and breast cancer tissues were 4.6 and 4 folds greater than that of their respective normal tissues. While the gamma(min) values of neck cancer tissue showed 95% increase from normal tissue values, those of vulval and breast cancer tissues were 46 and 5090 less compared to their respective normal tissue values. Though all the surface tensiometric parameters showed significant changes, minimum surface tension and hysteresis area were the most sensitive indicators of tissue types and diseased states. Further, the effects of therapeutics could also be monitored by this technique. This is evidenced by the post-radiotherapy tissue isotherms of neck and vulval cancers, where clinical radio-sensitivity was associated with a shift in the tensiometry towards their respective normal isotherms. The small sample amounts required, precision of the technique. very low within group variability. organ specificity and sensitivity to detect changes in diseased states make it a promising tool for prognostic evaluation of diseased states and monitoring effects of therapeutics. Further research is warranted in this promising and hitherto unexplored field of tissue tensiometry. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [1] Surface modification using polymer Langmuir-Blodgett films
    Kado, Y
    Aoki, A
    Miyashita, T
    JOURNAL OF MATERIALS SCIENCE, 2002, 37 (22) : 4839 - 4843
  • [2] Surface modification using polymer Langmuir-Blodgett films
    Y. Kado
    A. Aoki
    T. Miyashita
    Journal of Materials Science, 2002, 37 : 4839 - 4843
  • [3] Surface topography of acetylcholinesterase in Langmuir and Langmuir-Blodgett films
    Dziri, L
    Boussaad, S
    Wang, SP
    Leblanc, RM
    JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (34): : 6741 - 6748
  • [4] Use of dynamic surface tensiometry to determine the stability of proteins in solution.
    Sun, B
    Chang, BS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 299 - BIOT
  • [5] Acoustofluidic dynamic interfacial tensiometry
    Farooq, Umar
    Liu, Yuanting
    Li, Pengqi
    Deng, Zhiting
    Liu, Xiufang
    Zhou, Wei
    Yi, Shasha
    Rong, Ning
    Meng, Long
    Niu, Lili
    Zheng, Hairong
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 150 (05): : 3608 - 3617
  • [6] SURFACE ACOUSTIC-WAVE DEVICES USING LANGMUIR-BLODGETT-FILMS
    PLESSKII, VP
    SOVIET PHYSICS ACOUSTICS-USSR, 1991, 37 (03): : 215 - 220
  • [7] Measurement of surface and interfacial tension using pendant drop tensiometry
    Berry, Joseph D.
    Neeson, Michael J.
    Dagastine, Raymond R.
    Chan, Derek Y. C.
    Tabor, Rico F.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2015, 454 : 226 - 237
  • [8] Two-dimensional pendant droplet tensiometry in a Langmuir monolayer
    Heinig, P
    Steffen, P
    Wurlitzer, S
    Fischer, TM
    LANGMUIR, 2001, 17 (21) : 6633 - 6637
  • [9] Bidirectional Photomodulation of Surface Tension in Langmuir Films
    Cheng, Jinling
    Stacko, Peter
    Rudolf, Petra
    Gengler, Regis Y. N.
    Feringa, Ben L.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (01) : 291 - 296
  • [10] Surface chemistry study of β-amyloid Langmuir and Langmuir-Blodgett films.
    Orbulescu, J
    Patrick, ML
    Li, CQ
    Leblanc, RM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U254 - U254