Gas exchange and lung mechanics during percutaneous transtracheal ventilation in an unparalyzed canine model

被引:2
|
作者
Tran, TP [1 ]
Rhee, KJ
Schultz, HD
Carl, ML
机构
[1] Univ Nebraska, Med Ctr, Dept Surg, Sect Emergency Med, Omaha, NE 68198 USA
[2] Kaiser Permanente Med Ctr, Dept Emergency Med, Sacramento, CA USA
[3] Univ Calif Davis, Med Ctr, Div Emergency Med, Sacramento, CA 95817 USA
关键词
intubation; pulmonary; jet ventilation; lung compliance; resistance; paralysis; airway; animal model;
D O I
10.1111/j.1553-2712.1998.tb02712.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the efficacy of percutaneous transtracheal ventilation (PTV) in the unparalyzed state with that in the paralyzed stare using a sedated nonobstructed canine model. Methods: Eight mongrel dogs (16.8-32 kg) were anesthetized, instrumented, and placed in a volume plethysmograph. Anesthesia was achieved with pentobarbital sodium (up to 30 mg/kg). The spontaneous respiratory drive was kept intact. PTV was performed using a 13-ga transtracheal catheter and compressed air at 45 psi at an I:E ratio of 1:3 (15 breaths/min). Each dog was sequentially ventilated in both the paralyzed and unparalyzed states, The paralyzed/unparalyzed sequence was alternated among the animals to avoid sequence bias. Paralysis was achieved with succinylcholine (0.1 mg/kg bolus and 0.01 mg/kg/min drip). Reversal of paralysis was achieved by discontinuing the succinylcholine infusion. Key variables, including arterial blood gas, tidal volume, and pulmonary mechanics, were measured and compared for the paralyzed and unparalyzed stales. Results: Gas exchanges and lung mechanics were similar between the unparalyzed and paralyzed states. There was no significant difference in mean pH, pCO(2), pO(2), tidal volume, or peak inspiratory transpulmonary pressure. There was also no significant difference in pulmonary resistance or pulmonary compliance. Conclusion: In a sedated nonobstructed canine model, PTV is as efficacious in the unparalyzed state as it is in the paralyzed state, The lung mechanics are also similar in the states. These data suggest that it may be unnecessary to induce paralysis when using PTV for emergency ventilation in the heavily sedated state.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 50 条
  • [1] Jet or intensive care unit ventilator during simulated percutaneous transtracheal ventilation: a lung model study
    Liu, Y. H.
    Wang, A. L.
    Marchese, A. D.
    Kacmarek, R. M.
    Jiang, Y.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (03) : 456 - 462
  • [2] Effects of Paralysis on Lung Mechanics and Gas Exchange during Partial Liquid Ventilation
    Ellen M Bendel-Stenzel
    Joel M Manaligod
    Dennis R Bing
    Pat A Meyers
    John E Connett
    Mark C Mammel
    Pediatric Research, 1999, 45 : 295 - 295
  • [3] Effects of paralysis on lung mechanics and gas exchange during partial liquid ventilation
    Bendel-Stenzel, EM
    Manaligod, JM
    Bing, DR
    Meyers, PA
    Connett, JE
    Mammel, MC
    PEDIATRIC RESEARCH, 1999, 45 (04) : 295A - 295A
  • [4] PULMONARY MECHANICS OF DOGS DURING TRANSTRACHEAL JET VENTILATION
    CARL, ML
    RHEE, KJ
    SCHELEGLE, ES
    GREEN, JF
    ANNALS OF EMERGENCY MEDICINE, 1994, 24 (06) : 1126 - 1136
  • [5] Gas exchange and lung mechanics during high frequency ventilation in the perflubron-treated lung
    Wolf, Gerhard K.
    Sheeran, Padraig
    Heitz, David
    Thompson, John E.
    Arnold, John H.
    PEDIATRIC CRITICAL CARE MEDICINE, 2008, 9 (06) : 641 - 646
  • [6] Effects of paralysis on lung mechanics and gas exchange during partial liquid ventilation.
    Bendel-Stenzel, EM
    Manaligod, J
    Bing, DR
    Meyers, PA
    Connett, JE
    Mammel, MC
    JOURNAL OF INVESTIGATIVE MEDICINE, 1999, 47 (02) : 94A - 94A
  • [7] Variable peak pressure ventilation improves lung mechanics and gas exchange during long term mechanical ventilation in a Rodent model of ARDS
    Arold, Stephen
    Mora, Rene
    Lutchen, Kenneth
    Ingenito, Edward
    Suki, Bela
    Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [8] Multifrequency Oscillatory Ventilation in the Premature Lung Effects on Gas Exchange, Mechanics, and Ventilation Distribution
    Kaczka, David W.
    Herrmann, Jacob
    Zonneveld, C. Elroy
    Tingay, David G.
    Lavizzari, Anna
    Noble, Peter B.
    Pillow, J. Jane
    ANESTHESIOLOGY, 2015, 123 (06) : 1394 - 1403
  • [9] Variable tidal volume ventilation improves lung mechanics and gas exchange in a rodent model of acute lung injury
    Arold, SP
    Mora, R
    Lutchen, KR
    Ingenito, EP
    Suki, B
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (03) : 366 - 371
  • [10] Lung mechanics and gas exchange in one-lung ventilation following contralateral resection
    Ruiz, P
    Kovarik, G
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (09): : 986 - 989