High-birefringence microfiber Sagnac interferometer based humidity sensor

被引:91
|
作者
Sun, Li-Peng [1 ]
Li, Jie [1 ]
Jin, Long [1 ]
Ran, Yang [1 ]
Guan, Bai-Ou [1 ]
机构
[1] Jinan Univ, Inst Photon Technol, Guangdong Prov Key Lab Opt Fiber Sensing & Commun, Guangzhou 510632, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Humidity sensor; Fiber-optic sensors; Micro-optical devices; FIBER; LOOP;
D O I
10.1016/j.snb.2016.03.102
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A relative humidity (RH) sensor based on a microfiber Sagnac loop interferometer is proposed and demonstrated. The sensor is formed by fusion splicing a high-birefringence elliptical microfiber into a fiber loop mirror without any humidity sensitive coating to the structure. Interferometric fringe with visibility of around 30 dB can be achieved in the transmission spectrum due to phase difference between the two polarization modes travelling through the microfiber region. The proposed structure presents high sensitivity up to similar to 201.25 pm/%RH, within an RH range from 30%RH to 90%RH. Moreover, we realize the sensitivity enhancement (up to similar to 422.2 pm/%RH) by inserting a reference Panda fiber into the fiber loop. The sensitivity is two to five times of magnitude higher than the counterparts in the literature. The measured response time is around 60 ms, which is much better than the previously-reported devices. (C) 2016 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.olg/licenses/by-nc-nd/4.0/).
引用
收藏
页码:696 / 700
页数:5
相关论文
共 50 条
  • [1] A High-Birefringence Microfiber Sagnac-Interferometer Biosensor Based on the Vernier Effect
    Wang, Xue-Zhou
    Wang, Qi
    [J]. SENSORS, 2018, 18 (12)
  • [2] Sensitivity characteristics of high-birefringence Sagnac interferometer sensors
    Zu, Peng
    Chan, Chi Chiu
    Liang, Ziyang
    Jin, Yongxing
    Wong, Wei Chang
    Chen, Li Han
    Dong, Xinyong
    [J]. 22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [3] Brief review of the present status of the Sagnac interferometer using high-birefringence optical fibers
    Cerecedo-Núñez, HH
    Kuzin, EA
    [J]. REVISTA MEXICANA DE FISICA, 2000, 46 (05) : 512 - 517
  • [4] A Sagnac filter composed of high-birefringence loops
    Liu, LH
    Zhao, LM
    Zhou, G
    Zhang, H
    Hu, SY
    Huang, GL
    He, SY
    Zhao, Q
    [J]. PASSIVE COMPONENTS AND FIBER-BASED DEVICES, PTS 1 AND 2, 2005, 5623 : 867 - 871
  • [5] Magnetic Field Measurement Based on the Sagnac Interferometer With a Ferrofluid-Filled High-Birefringence Photonic Crystal Fiber
    Zhao, Yong
    Wu, Di
    Lv, Ri-Qing
    Li, Jin
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (06) : 1503 - 1507
  • [6] Magnetic Field Sensor Based on Microfiber Sagnac Loop Interferometer and Ferrofluid
    Lv, Fangxing
    Han, Chunyang
    Ding, Hui
    Wu, Zhongying
    Li, Xianli
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2015, 27 (22) : 2327 - 2330
  • [7] A fiber strain and vibration sensor with high birefringence polarization maintaining fiber based on Sagnac interferometer
    Li, Yi
    Sun, Miao
    Dong, Xinyong
    Zhang, Zaixuan
    Jin, Shangzhong
    [J]. 2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2011, 8201
  • [8] Seawater Temperature Measurement Based on a High-Birefringence Elliptic Fiber Sagnac Loop
    Wang, Xin
    Yang, Hong-Juan
    Wang, Shan-Shan
    Liao, Yi-Peng
    Wang, Jing
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2015, 27 (16) : 1772 - 1775
  • [9] High-sensitivity DNA biosensor based on microfiber Sagnac interferometer
    Gao, Shuai
    Sun, Li-Peng
    Li, Jie
    Jin, Long
    Ran, Yang
    Huang, Yunyun
    Guan, Bai-Ou
    [J]. OPTICS EXPRESS, 2017, 25 (12): : 13305 - 13313
  • [10] All-fiber absolute temperature sensor using an unbalanced high-birefringence Sagnac loop
    DelaRosa, E
    Zenteno, LA
    Starodumov, AN
    Monzon, D
    [J]. OPTICS LETTERS, 1997, 22 (07) : 481 - 483