Quantitative coronary angiographic and intravascular ultrasound assessment of a new nonarticulated stent: Report from the advanced cardiovascular systems MultiLink stent pilot study

被引:32
|
作者
Carrozza, JP
Hermiller, JB
Linnemeier, TJ
Popma, JJ
Yock, PG
Roubin, GS
Dean, LS
Kuntz, RE
Robertson, L
Ho, KKL
Cutlip, DE
Baim, DS
机构
[1] Beth Israel Deaconess Med Ctr, Div Cardiovasc, Sect Intervent Cardiol, Boston, MA 02215 USA
[2] St Vincents Hosp, Indiana Heart Inst, Indianapolis, IN USA
[3] Stanford Univ, Med Ctr, Ctr Res Intervent Cardiol, Stanford, CA 94305 USA
[4] Washington Cardiol Ctr, Washington, DC USA
[5] Univ Alabama, Div Cardiol, Birmingham, AL USA
关键词
D O I
10.1016/S0735-1097(97)00426-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and I-year clinical outcome for the Advanced Cardiovascular Systems (ACS) Multilink stent, Background. Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome. Methods. Forty-nine consecutive patients with a discrete stenosis in a native coronary artery 3 to 4 mm in diameter were treated with the new, balloon-expandable ACS MultiLink stent. Stent expansion was assessed in all patients using quantitative coronary angiography and serial IVUS imaging after 8-, 12- and 16-atm inflations., Clinical follow up was obtained at 30 days and 1 gear. Results. All 49 patients had successful placement of a Multilink stent without death, emergency coronary artery bypass graft surgery or Q wave myocardial infarction, After placement of the MultiLink stent, the minimal lumen diameter increased from 1.24 to 2.98 mm (p < 0.001), and diameter stenosis decreased from 61% to 7% (p = 0.001), Minimal lumen cross-sectional area by NUS increased progressively after 8, 12 and 16 atm (5.6 to 6.8 to 7.4 mm(2), respectively, p < 0.001), However, only 61% of stents achieved a lumen/reference area ratio greater than or equal to 70%. No adverse clinical events occurred by 30 days, and by 1 year only one patient (2.0%) required revascularization of the stented artery, Conclusions. Treatment of stenoses in native coronary arteries with the MultiLink stent is associated with a high success rate and a low incidence of adverse events by 1 year, despite the fact that the majority of stents did not meet IVUS-defined criteria for "optimal stenting" derived from first-generation devices. (C) 1998 by the American College of Cardiology.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 44 条
  • [1] Angiography versus intravascular ultrasound assessment of coronary stent placement: Observations from the AVID study
    Russo, RJ
    Wong, SC
    Lucisano, JE
    Silva, P
    Ling, FS
    Fitzgerald, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 387A - 387A
  • [2] Intravascular ultrasound assessment of a new biodegradable self-expanding coronary stent in humans
    Komori, H
    Tsuji, T
    Tamai, H
    Kyo, E
    Kosuga, K
    Kawashima, A
    Matsui, S
    Hata, T
    Motohara, S
    Uehata, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 34A - 34A
  • [3] Impact of vessel wall injury on in-stent restenosis: A serial quantitative angiographic and intravascular ultrasound study
    Mehran, R
    Mintz, GS
    Pichard, AD
    Satler, LF
    Hong, MK
    Hoffmann, R
    DeForty, D
    Morgan, C
    Griffin, J
    Leon, MB
    CIRCULATION, 1996, 94 (08) : 1535 - 1535
  • [4] Assessment of coronary stent expansion: Angiographic diameter versus intravascular ultrasound cross-sectional area: Observations from AVID
    Russo, RJ
    Attubato, MJ
    Davidson, CJ
    DeFranco, AC
    Fitzgerald, PJ
    Hermiller, JB
    Iaffaldano, RA
    Ling, FS
    Lucisano, JE
    Silva, PD
    Smith, GJ
    Wong, SC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 27A - 27A
  • [5] Sirolimus-eluting stent for the treatment of in-stent restenosis - A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    Sousa, JE
    Costa, MA
    Abizaid, A
    Sousa, AGMR
    Feres, F
    Mattos, LA
    Centemero, M
    Maldonado, G
    Abizaid, AS
    Pinto, I
    Falotico, R
    Jaeger, J
    Popma, JJ
    Serruys, PW
    CIRCULATION, 2003, 107 (01) : 24 - 27
  • [6] THE REMEDEE STUDY: INSIGHTS FROM THE ANGIOGRAPHIC AND INTRAVASCULAR ULTRASOUND COMPARISON OF A COMBINATION SIROLIMUS ELUTING EPC CAPTURE STENT WITH A PACLITAXEL ELUTING STENT
    Haude, Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E209 - E209
  • [7] Is intravascular ultrasound necessary after high pressure stent deployment? Immediate and late angiographic outcome compared to quantitative coronary angiography
    Sallam, M
    di Mario, C
    Albiero, R
    Colombo, A
    EUROPEAN HEART JOURNAL, 2000, 21 : 507 - 507
  • [8] Comparison of quantitative coronary angiography, intravascular ultrasound and Doppler flowire in the physiological assessment of in-stent restenosis.
    Montorsi, P
    Grancini, L
    Fabbiocchi, F
    Trabattoni, D
    Ravagnani, P
    Loaldi, A
    Cozzi, S
    Galli, S
    Bartorelli, AL
    CIRCULATION, 2001, 104 (17) : 456 - 456
  • [9] Comparison of quantitative coronary angiography, intravascular ultrasound, and Doppler flowire in the physiological assessment of in-stent restenosis.
    Montorsi, P
    Grancini, L
    Fabbiocchi, F
    Trabattoni, D
    Galli, S
    Bartorelli, AL
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 50G - 50G
  • [10] Intravascular ultrasound and quantitative coronary angiography assessment of late in-stent restenosis: In vivo human correlation and methodological implications
    Prati, F
    Pawlowski, T
    Sommariva, L
    Labellarte, A
    Manzoli, A
    Boccanelli, A
    Motolese, M
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (02) : 155 - 160