Organ Dose and Attributable Cancer Risk in Lung Cancer Screening with Low-Dose Computed Tomography

被引:25
|
作者
Saltybaeva, Natalia [1 ]
Martini, Katharina [1 ]
Frauenfelder, Thomas [1 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich, Inst Diagnost & Intervent Radiol, Univ Zurich Hosp, Zurich, Switzerland
来源
PLOS ONE | 2016年 / 11卷 / 05期
关键词
CHEST CT;
D O I
10.1371/journal.pone.0155722
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose Lung cancer screening with CT has been recently recommended for decreasing lung cancer mortality. The radiation dose of CT, however, must be kept as low as reasonably achievable for reducing potential stochastic risks from ionizing radiation. The purpose of this study was to calculate individual patients' lung doses and to estimate cancer risks in low-dose CT (LDCT) in comparison with a standard dose CT (SDCT) protocol. Materials and Methods This study included 47 adult patients (mean age 63.0 +/- 5.7 years) undergoing chest CT on a third-generation dual-source scanner. 23/47 patients (49%) had a non-enhanced chest SDCT, 24 patients (51%) underwent LDCT at 100 kVp with spectral shaping at a dose equivalent to a chest x-ray. 3D-dose distributions were obtained from Monte Carlo simulations for each patient, taking into account their body size and individual CT protocol. Based on the dose distributions, patient-specific lung doses were calculated and relative cancer risk was estimated according to BEIR VII recommendations. Results As compared to SDCT, the LDCT protocol allowed for significant organ dose and cancer risk reductions (p<0.001). On average, lung dose was reduced from 7.7 mGy to 0.3 mGy when using LDCT, which was associated with lowering of the cancer risk from 8.6 to 0.35 per 100'000 cases. A strong linear correlation between lung dose and patient effective diameter was found for both protocols (R-2 = 0.72 and R-2 = 0.75 for SDCT and LDCT, respectively). Conclusion Use of a LDCT protocol for chest CT with a dose equivalent to a chest x-ray allows for significant lung dose and cancer risk reduction from ionizing radiation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Lung Cancer Screening With Low-Dose Computed Tomography
    Loebig, Stephanie
    Haegele, Patricia
    Seizer, Peter
    [J]. DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (41):
  • [2] Lung cancer screening with low-dose computed tomography
    Seijo Maceiras, Luis M.
    [J]. MEMO-MAGAZINE OF EUROPEAN MEDICAL ONCOLOGY, 2014, 7 (01) : 6 - 9
  • [3] Lung cancer screening with low-dose computed tomography
    Hartman, TE
    Swensen, SJ
    [J]. SEMINARS IN ROENTGENOLOGY, 2003, 38 (01) : 34 - 38
  • [4] Lung Cancer Screening With Low-Dose Computed Tomography
    Reck, Martin
    Dettmer, Sabine
    Kauczor, Hans-Ulrich
    Kaaks, Rudolf
    Reinmuth, Niels
    Vogel-Claussen, Jens
    [J]. DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (23): : 387 - +
  • [5] Low-Dose Computed Tomography Screening for Lung Cancer
    Welch, Laura S.
    Madtes, David
    Ringen, Knut
    [J]. ANNALS OF INTERNAL MEDICINE, 2015, 162 (06) : 459 - 460
  • [6] Lung Cancer Screening with Low-Dose Computed Tomography
    Chiles, Caroline
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (01) : 27 - +
  • [7] Screening for Lung Cancer With Low-Dose Computed Tomography
    Miller, Anthony B.
    [J]. ONCOLOGIST, 2013, 18 (08): : 897 - 899
  • [8] Lung cancer screening with low-dose computed tomography
    Luis M. Seijo Maceiras
    [J]. memo - Magazine of European Medical Oncology, 2014, 7 (1) : 6 - 9
  • [9] Screening for lung cancer with low-dose computed tomography
    Diederich, S
    Wormanns, D
    Heindel, W
    [J]. RADIOLOGE, 2001, 41 (03): : 256 - 260
  • [10] Screening for Lung Cancer With Low-Dose Computed Tomography
    Brodersen, John
    Dirksen, Asger
    Pedersen, Jesper Holst
    [J]. ANNALS OF INTERNAL MEDICINE, 2014, 160 (03) : 211 - 212