Comparing Diagnostic Performance of Digital Breast Tomosynthesis and Full-Field Digital Mammography in a Hybrid Screening Environment

被引:36
|
作者
Giess, Catherine S. [1 ]
Pourjabbar, Sarvenaz [1 ,2 ]
Ip, Ivan K. [1 ]
Lacson, Ronilda [1 ]
Alper, Emily [1 ]
Khorasani, Ramin [1 ]
机构
[1] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Ctr Evidence Based Imaging, 75 Francis St, Boston, MA 02115 USA
[2] Yale Univ, Sch Med, Dept Radiol, New Haven, CT 06510 USA
关键词
breast; cancer detection; digital breast tomosynthesis; full-field digital mammography; screening; PROPENSITY SCORE; IMPLEMENTATION; COMBINATION;
D O I
10.2214/AJR.17.17983
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to compare the diagnostic performance of screening digital breast tomosynthesis (DBT) to that of full-field digital mammography (FFDM) in a mixed DBT and FFDM imaging environment. MATERIALS AND METHODS. This retrospective observational study consisted of all female patients undergoing screening DBT or FFDM at an academic medical center and outpatient imaging facility between October 2012 and May 2015. Patient demographics and personal history of breast cancer were collected from the electronic medical record. A natural language processing algorithm extracted patients' breast density, current or prior imaging findings, and BI-RADS category from their most recent prior imaging examinations. To control for differential selection of FFDM versus DBT, we applied propensity score matching based on patient age, imaging site, and prior imaging findings. An institutional breast cancer registry identified cancer diagnoses. Primary outcomes of recall rate, cancer detection rate, and positive predictive value 1 (PPV1) were compared between matched FFDM and DBT groups. RESULTS. Among 68,794 screening examinations, we matched 16,264 FFDM with 21,074 DBT examinations (total, 37,338 examinations) using nearest neighbor propensity score matching. Recall rates were 10.3% (1683/16,264) for FFDM and 10.7% (2254/21,074) for DBT (p = 0.26). Cancer detection rates (number of cancers/1000 examinations) were 1.8/1000 for FFDM and 3.8/1000 for DBT (p = 0.005). The PPV1 (number of cancers/number of recalls) was 1.8% (26/1478) for FFDM and 3.6% (37/1036) for DBT (p = 0.006). CONCLUSION. FFDM and DBT recall rates were not significantly different in a mixed FFDM and DBT breast imaging practice. However, the PPV1 of recalled cases and the cancer detection rate (the primary screening objective) were significantly higher with DBT compared with FFDM.
引用
收藏
页码:929 / 934
页数:6
相关论文
共 50 条
  • [1] Comparing Diagnostic Performance of Digital Breast Tomosynthesis and Full-Field Digital Mammography
    Cochon, Laila R.
    Giess, Catherine S.
    Khorasani, Ramin
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (08) : 999 - 1003
  • [2] Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis
    McDonald, Elizabeth S.
    McCarthy, Anne Marie
    Akhtar, Amana L.
    Synnestvedt, Marie B.
    Schnall, Mitchell
    Conant, Emily F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1143 - 1148
  • [3] AN OBSERVER PERFORMANCE STUDY COMPARING THE INTERPRETATION OF FULL-FIELD DIGITAL MAMMOGRAPHY WITH DIGITAL BREAST TOMOSYNTHESIS
    Wasan, Rema K.
    Iqbal, Asif
    Evans, David R.
    Peacock, Clare
    Morel, Juliet C.
    Douiri, Abdel
    Michell, Michael J.
    EJC SUPPLEMENTS, 2010, 8 (06): : 32 - 32
  • [4] Comparing Tumor Characteristics and Rates of Breast Cancers Detected by Screening Digital Breast Tomosynthesis and Full-Field Digital Mammography
    Dang, Pragya A.
    Wang, Aijia
    Senapati, Gunjan M.
    Ip, Ivan K.
    Lacson, Ronilda
    Khorasani, Ramin
    Giess, Catherine S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (03) : 701 - 706
  • [5] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [6] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [7] Comparing the diagnostic efficacy of digital breast tomosynthesis with full-field digital mammography using BI-RADS scoring
    Naeim, Rana M.
    Marouf, Rania A.
    Nasr, Merhan A.
    Abd El-Rahman, Marwa E.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [8] Comparing the diagnostic efficacy of digital breast tomosynthesis with full-field digital mammography using BI-RADS scoring
    Rana M. Naeim
    Rania A. Marouf
    Merhan A. Nasr
    Marwa E. Abd El-Rahman
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [9] Clinical performance of digital breast tomosynthesis versus full-field digital mammography: Preliminary results
    Gennaro, Gisella
    Baldan, Enrica
    Bezzon, Elisabetta
    La Grassa, Manuela
    Pescarini, Luigi
    di Maggio, Cosimo
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 477 - 482
  • [10] Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
    Li, Juntao
    Zhang, Hengwei
    Jiang, Hui
    Guo, Xuhui
    Zhang, Yinli
    Qi, Dan
    Guan, Jitian
    Liu, Zhenzhen
    Wu, Erxi
    Luo, Suxia
    COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2019, 17 : 82 - 89