Geometrically induced wall shear stress variability in CFD-MRI coupled simulations of blood flow in the thoracic aortas

被引:23
|
作者
Perinajova, Romana [1 ,2 ]
Juffermans, Joe F. [3 ]
Westenberg, Jos J. M. [3 ]
van der Palen, Roel L. F. [4 ]
van den Boogaard, Pieter J. [3 ]
Lamb, Hildo J. [3 ]
Kenjeres, Sasa [1 ,2 ]
机构
[1] Delft Univ Technol, Fac Sci Appl, Dept Chem Engn, Delft, Netherlands
[2] JM Burgersctr, Res Sch Fluid Mech, Delft, Netherlands
[3] Leiden Univ, Dept Radiol, Med Ctr, Leiden, Netherlands
[4] Leiden Univ, Div Pediat Cardiol, Dept Pediat, Med Ctr, Leiden, Netherlands
关键词
Aorta; Segmentation; Wall shear stress; CFD; MRI; FLUID; REPRODUCIBILITY; PATTERNS; VELOCITY; VECTORS;
D O I
10.1016/j.compbiomed.2021.104385
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aortic aneurysm is associated with aberrant blood flow and wall shear stress (WSS). This can be studied by coupling magnetic resonance imaging (MRI) with computational fluid dynamics (CFD). For patient-specific simulations, extra attention should be given to the variation in segmentation of the MRI data-set and its effect on WSS. We performed CFD simulations of blood flow in the aorta for ten different volunteers and provided corresponding WSS distributions. The aorta of each volunteer was segmented four times. The same inlet and outlet boundary conditions were applied for all segmentation variations of each volunteer. Steady-state CFD simulations were performed with inlet flow based on phase-contrast MRI during peak systole. We show that the commonly used comparison of mean and maximal values of WSS, based on CFD in the different segments of the thoracic aorta, yields good to excellent correlation (0.78-0.95) for rescan and moderate to excellent correlation (0.64-1.00) for intra- and interobserver reproducibility. However, the effect of geometrical variations is higher for the voxel-to-voxel comparison of WSS. With this analysis method, the correlation for different segments of the whole aorta is poor to moderate (0.43-0.66) for rescan and poor to good (0.48-0.73) for intra- and interobserver reproducibility. Therefore, we advise being critical about the CFD results based on the MRI segmentations to avoid possible misinterpretation. While the global values of WSS are similar for different modalities, the variation of results is high when considering the local distributions.
引用
收藏
页数:19
相关论文
共 25 条
  • [1] Wall shear stress and atherosclerosis: Numerical blood flow Simulations in the mouse aortic arch
    Ruengsakulrach, P.
    Joshi, A. K.
    Fremes, S.
    Butany, J.
    Foster, S.
    Wiwatanapataphee, B.
    Lenbury, Y.
    APPLIED MATHEMATICS FOR SCIENCE AND ENGINEERING, 2007, : 199 - +
  • [2] Pulsatile Blood Flow Simulations in Aortic Arch: Effects of Blood Pressure and the Geometry of Arch on Wall Shear Stress
    Vasava, P.
    Jalali, P.
    Dabagh, M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1926 - 1929
  • [3] Pulsatile blood flow simulations and the correlation of endothelial wall shear stress and coronary atherosclerosis in patients in vivo
    Hetterich, H.
    Curta, A.
    Jaber, A.
    Gehring, M.
    Redel, T.
    Klauss, V.
    Rieber, J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 149 - 149
  • [4] Assessment of turbulent blood flow and wall shear stress in aortic coarctation using image-based simulations
    Romana Perinajová
    Joe F. Juffermans
    Jonhatan Lorenzo Mercado
    Jean-Paul Aben
    Leon Ledoux
    Jos J. M. Westenberg
    Hildo J. Lamb
    Saša Kenjereš
    BioMedical Engineering OnLine, 20
  • [5] Assessment of turbulent blood flow and wall shear stress in aortic coarctation using image-based simulations
    Perinajova, Romana
    Juffermans, Joe F.
    Mercado, Jonhatan Lorenzo
    Aben, Jean-Paul
    Ledoux, Leon
    Westenberg, Jos J. M.
    Lamb, Hildo J.
    Kenjeres, Sasa
    BIOMEDICAL ENGINEERING ONLINE, 2021, 20 (01)
  • [6] Normal patterns of thoracic aortic wall shear stress measured using four-dimensional flow MRI in a large population
    Callaghan, Fraser M.
    Grieve, Stuart M.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2018, 315 (05): : H1174 - H1181
  • [7] Permeability and fluid flow-induced wall shear stress in bone scaffolds with TPMS and lattice architectures: A CFD analysis
    Ali, Davar
    Ozalp, Mehmet
    Blanquer, Sebastien B. G.
    Onel, Selis
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2020, 79 : 376 - 385
  • [8] Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta
    van Ooij, Pim
    Powell, Alexander L.
    Potters, Wouter V.
    Carr, James C.
    Markl, Michael
    Barker, Alex J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 236 - 248
  • [9] Reduction of carotid artery wall shear stress and blood flow due to induced snoring in an animal model
    Cho, J. -G.
    Verma, M.
    Narayan, J.
    Larcos, G.
    Amis, T.
    Wheatley, J.
    JOURNAL OF SLEEP RESEARCH, 2011, 20 : 19 - 19
  • [10] A Methodology to Detect Abnormal Relative Wall Shear Stress on the Full Surface of the Thoracic Aorta Using Four-Dimensional Flow MRI
    van Ooij, Pim
    Potters, Wouter V.
    Nederveen, Aart J.
    Allen, Bradley D.
    Collins, Jeremy
    Carr, James
    Malaisrie, S. Chris
    Markl, Michael
    Barker, Alex J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 1216 - 1227