Preventive/corrective control for voltage stability based on primal-dual interior point method

被引:0
|
作者
Yuan, Yue [1 ]
Wen, Xuehong [1 ]
Qian, Kejun [1 ]
机构
[1] Hohai Univ, Coll Elect Engn, Nanjing, Peoples R China
关键词
electric power system; preventive/corrective control; voltage stability; optimal power flow; interior point method;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The preventive/corrective control for voltage stability is an indispensable part of on-line voltage monitoring system. Hidden trouble of voltage stability could be eliminated by cooperation of preventive control and corrective control, thus the operating point could be in secure area continually. In this paper, a 168-bus real power system was investigated to illustrate how to solve optimal control problem using Primal-Dual Interior Point Method (PDIPM). Additionally, this paper presents a new scheme of voltage collapse preventive control problem, coordinating the optimal power flow (OPF) computation with the automatic voltage control (AVC) system. This new scheme proposed has been recognized by engineering practice.
引用
收藏
页码:2092 / +
页数:2
相关论文
共 50 条
  • [1] Discussion about the corrective control for voltage stability of complex power systems based on primal-dual interior point method
    Yuan, Yue
    Qian, Kejun
    Wen, Xuehong
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2097 - +
  • [2] Preventive/corrective control for voltage stability using direct interior point method
    Wang, X
    Ejebe, GC
    Tong, J
    Waight, JG
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1998, 13 (03) : 878 - 883
  • [3] Preventive/corrective control for voltage stability using direct interior point method
    Siemens Power Systems Control, Brooklyn Park, United States
    IEEE Trans Power Syst, 3 (878-883):
  • [4] Preventive/corrective control for voltage stability using direct interior point method
    Wang, X
    Ejebe, GC
    Tong, J
    Waight, JG
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON POWER INDUSTRY COMPUTER APPLICATIONS, 1996, : 312 - 317
  • [5] On a Primal-Dual Interior Point Filter Method
    Costa, M. Fernanda P.
    Fernandes, Edite M. G. P.
    NUMERICAL ANALYSIS AND APPLIED MATHEMATICS ICNAAM 2011: INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS, VOLS A-C, 2011, 1389
  • [6] Reoptimization with the primal-dual interior point method
    Gondzio, J
    Grothey, A
    SIAM JOURNAL ON OPTIMIZATION, 2003, 13 (03) : 842 - 864
  • [7] ON THE IMPLEMENTATION OF A PRIMAL-DUAL INTERIOR POINT METHOD
    Mehrotra, Sanjay
    SIAM JOURNAL ON OPTIMIZATION, 1992, 2 (04) : 575 - 601
  • [8] Primal-dual interior point method based real-time voltage/reactive power control algorithm
    Li, Naihu
    Ding, Qia
    Wang, Xiaodong
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2000, 24 (05): : 23 - 60
  • [9] An ε-sensitivity analysis in the primal-dual interior point method
    Kim, WJ
    Park, CK
    Park, S
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 1999, 116 (03) : 629 - 639
  • [10] Preventive/corrective control for voltage stability using predictor-corrector interior point method
    Guo, RP
    Han, ZX
    Wang, Q
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1513 - 1517