A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins -: An in vivo study in sheep

被引:87
|
作者
Moroni, A [1 ]
Toksvig-Larsen, S [1 ]
Maltarello, MC [1 ]
Orienti, L [1 ]
Stea, S [1 ]
Giannini, S [1 ]
机构
[1] Univ Bologna, Rizzoli Orthopaed Inst, Dept Orthopaed Surg, I-40136 Bologna, Italy
来源
关键词
D O I
10.2106/00004623-199804000-00011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Three types of surfaces for external fixation pins were compared. One hundred and eight stainless-steel tapered 5/6-millimeter pins were divided into three groups: thirty-six pins remained uncoated (Group A), thirty-six were plasma-sprayed with hydroxyapatite (Group B), and thirty-six were plasma-sprayed with titanium (Group C), The pins were implanted in the left tibia of eighteen sheep, with each sheep receiving six pins from the same group, A unilateral fixator then was assembled on the pins. The medial aspect of the mid-part of the tibial diaphysis was exposed, and a five-millimeter-long cylinder of bone was removed so that load would be borne by the bone-pin interfaces. Six weeks after the procedure, radiographs demonstrated rarefaction of twenty-nine pin tracks in Group A, fifteen in Group B, and thirty in Group C (p = 0.021 for Group A compared with Group B and p = 0.016 for Group B compared with Group C), The mean final insertion torque land standard deviation) was 4360 +/- 1050 newton-millimeters in Group A, 3420 +/- 676 newton-millimeters in Group B, and 3740 +/- 643 newton-millimeters in Group C, With the numbers available, no significant differences could be detected among these values. The mean extraction torque was 253 +/- 175 newton-millimeters in Group A, 3360 +/- 1260 newton-millimeters in Group B, and 1720 +/- 1030 newton-millimeters in Group C (p = 0.002 for Group A compared with Group B, p = 0.017 for Group A compared with Group C, and p = 0.03 for Group B compared with Group C), The extraction torque was significantly lower than the corresponding insertion torque in both Group A (p < 0.001) and Group C (p = 0.003); no significant difference could be found, with the numbers available, in Group B (hydroxyapatite-coated pins), At sixty times magnification, direct contact was seen along a mean of 16 +/- 9 per cent of the bone-pin interface in Group A, 30 +/- 12 per cent of the interface in Group B, and 28 +/- 15 per cent of the interface in Group C (p = 0.042 for Group A compared with Group C), However, at 10,000 times magnification, direct bone-pin contact was found only in Group B. CLINICAL RELEVANCE: The better fixation and greater interface strength of the hydroxyapatite-coated tapered pins should lead to a substantial decrease in the frequency of loosening and infection and consequently to a remarkable improvement in the clinical results of external fixation.
引用
收藏
页码:547 / 554
页数:8
相关论文
共 50 条
  • [1] Hydroxyapatite-coated external fixation pins
    Moroni, A
    Pegreffi, F
    Cadossi, M
    Hoang-Kim, A
    Lio, V
    Giannini, S
    EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (04) : 465 - 471
  • [2] Fixation strength of tapered versus bicylindrical hydroxyapatite-coated external fixation pins: An animal study
    Moroni, A
    Faldini, C
    Pegreffi, F
    Giannini, S
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (01): : 61 - 64
  • [3] Hydroxyapatite-Coated Pins Versus Titanium Alloy Pins in External Fixation at the Wrist: A Controlled Cohort Study
    Pieske, Oliver
    Pichlmaier, Leopold
    Kaltenhauser, Felicitas
    Schramm, Nicolai
    Rubenbauer, Bianka
    Greiner, Axel
    Piltz, Stefan
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (04): : 845 - 851
  • [4] Comparison of hydroxyapatite-coated and uncoated pins for transfixation casting in horses
    不详
    PFERDEHEILKUNDE, 2012, 28 (06): : 723 - 724
  • [5] Comparison of hydroxyapatite-coated and uncoated pins for transfixation casting in horses
    Lescun, Timothy B.
    Baird, Debra K.
    Oliver, Laurinda J.
    Adams, Stephen B.
    Hawkins, Jan F.
    Moore, George E.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2012, 73 (05) : 724 - 734
  • [6] Bisphosphonate-coated external fixation pins appear similar to hydroxyapatite-coated pins in the tibial metaphysis and to uncoated pins in the shaft A randomized trial
    Toksvig-Larsen, Soren
    Aspenberg, Per
    ACTA ORTHOPAEDICA, 2013, 84 (03) : 314 - 318
  • [7] Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins
    Moroni, A
    Heikkila, J
    Magyar, G
    Toksvig-Larsen, S
    Giannini, S
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 209 - 217
  • [8] Hydroxyapatite coated external fixation pins - An experimental study
    Caja, VL
    Moroni, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (325) : 269 - 275
  • [9] Hydroxyapatite-coated external-fixation pins -: The effect on pin loosening and pin-track infection in leg lengthening for short stature
    Pizà, G
    Caja, VL
    González-Viejo, MA
    Navarro, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06): : 892 - 897
  • [10] Hydroxyapatite-coated pins dramatically improve the strength of fixation
    Moroni, A.
    Faldini, C.
    Vannini, F.
    Stigliano, V.
    Giannini, S.
    Key Engineering Materials, 2001, 192-195 : 1037 - 1042